The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Tapping mode atomic force microscopy in liquids
Abstract
Tapping mode atomic force microscopy in liquids gives a substantial improvement in imaging quality and stability over standard contact mode. In tapping mode the probe-sample separation is modulated as the probe scans over the sample. This modulation causes the probe to tap on the surface only at the extreme of each modulation cycle and therefore minimizes frictional forces that are present when the probe is constantly in contact with the surface. This imaging mode increases resolution and reduces sample damage on soft samples. For our initial experiments we used a tapping frequency of 17 kHz to image deoxyribonucleic acid plasmids on mica in water. When we imaged the same sample region with the same cantilever, the plasmids appeared 18 nm wide in contact mode and 5 nm in tapping mode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Self-citationMagnetic imaging by ‘‘force microscopy’’ with 1000 Å resolution
Martin, Y., & Wickramasinghe, H. K. (1987) · Applied Physics Letters · doi:10.1063/1.97800 · Cited by 1,151
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Self-citationTrue Atomic Resolution by Atomic Force Microscopy Through Repulsive and Attractive Forces
Ohnesorge, F., & Binnig, G. (1993) · Science · doi:10.1126/science.260.5113.1451 · Cited by 700
Forces in atomic force microscopy in air and water
Weisenhorn, A. L., Hansma, P. K., Albrecht, T. R., & Quate, C. F. (1989) · Applied Physics Letters · doi:10.1063/1.101024 · Cited by 632
Self-citationUsing force modulation to image surface elasticities with the atomic force microscope
Maivald, P., Butt, H. J., Gould, S. A. C., Prater, C. B., Drake, B., Gurley, J. A., Elings, V. B., & Hansma, P. K. (1991) · Nanotechnology · doi:10.1088/0957-4484/2/2/004 · Cited by 525
Self-citationWeisenhorn, A. L., Maivald, P., Butt, H.-J., & Hansma, P. K. (1992) · Physical Review B · doi:10.1103/physrevb.45.11226 · Cited by 485
Self-citationReconstruction of STM and AFM images distorted by finite-size tips
Keller, D. (1991) · Surface Science · doi:10.1016/0039-6028(91)90606-s · Cited by 322
Atomic force microscopy of long DNA: imaging in air and under water.
Lyubchenko, Y., Shlyakhtenko, L., Harrington, R., Oden, P., & Lindsay, S. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.6.2137 · Cited by 243
Atomic force microscopy of DNA in aqueous solutions
Hansma, H. G., Bezanilla, M., Zenhausern, F., Adrian, M., & Sinsheimer, R. L. (1993) · Nucleic Acids Research · doi:10.1093/nar/21.3.505 · Cited by 207
Lyubchenko, Y. L., Oden, P. I., Lampner, D., Lindsay, S. M., & Dunker, K. A. (1993) · Nucleic Acids Research · doi:10.1093/nar/21.5.1117 · Cited by 158
Recent advances in atomic force microscopy of DNA
Hansma, H. G., Sinsheimer, R. L., Groppe, J. C., Bruice, T. C., Elings, V. B., Gurley, G., Bezanilla, M., Mastrangelo, I. A., Hough, P. V. C., & Hansma, P. K. (1993) · Scanning · doi:10.1002/sca.4950150509 · Cited by 139
Self-citation
Cited by
Evidence for the Formation of Symmetric and Asymmetric DLPC-DAPC Lipid Bilayer Domains
Ritter, M., Schmidt, S., Jakab, M., Paulmichl, M., & Henderson, R. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350122 · Cited by 3,923
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Nanomechanical analysis of cells from cancer patients
Cross, S. E., Jin, Y.-S., Rao, J., & Gimzewski, J. K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.388 · Cited by 1,908
Covalently functionalized nanotubes as nanometre- sized probes in chemistry and biology
Wong, S. S., Joselevich, E., Woolley, A. T., Cheung, C. L., & Lieber, C. M. (1998) · Nature · doi:10.1038/27873 · Cited by 1,451
Circularization of mRNA by Eukaryotic Translation Initiation Factors
Wells, S. E., Hillner, P. E., Vale, R. D., & Sachs, A. B. (1998) · Molecular Cell · doi:10.1016/s1097-2765(00)80122-7 · Cited by 981
Self-citation
Metadata
- Authors
- Hansma, P. K., Cleveland, J. P., Radmacher, M., Walters, D. A., Hillner, P. E., Bezanilla, M., Fritz, M., Vie, D., Hansma, H. G., Prater, C. B., Massie, J., Fukunaga, L., Gurley, J., & Elings, V.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1994-03-28
- Volume
- 64
- Issue
- 13
- Pages
- 1738-1740
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2568203515
- Cited by
- 875
- References
- 13
- FWCI
- 20.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.