Biomagnetic instrumentation
The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Abstract
We present a review of recent developments of the instrumentation for measuring magnetic fields emanating from the human body and other biological systems. The techniques for using various types of field sensors in shielded and unshielded environments are described, with special attention paid to recent advances in the application of SQUID systems. We also outline the present technical frontiers and point to avenues along which further improvements in performance are desirable.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“since the 1980s, multichannel installation in highly performant MSRs was the most preferred choice also for MCG, under the influence of faster-growing research and development for clinical applications of magnetoencephalography (MEG) (26, 41)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [26]
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Quantum Fluctuations and Noise in Parametric Processes. I.
Louisell, W. H., Yariv, A., & Siegman, A. E. (1961) · Physical Review · doi:10.1103/physrev.124.1646 · Cited by 717
Primdahl, F. (1979) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/12/4/001 · Cited by 499
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Self-citationGiffard, R. P., Webb, R. A., & Wheatley, J. C. (1972) · Journal of Low Temperature Physics · doi:10.1007/bf00644085 · Cited by 288
Tunnel junction dc SQUID: Fabrication, operation, and performance
Clarke, J., Goubau, W. M., & Ketchen, M. B. (1976) · Journal of Low Temperature Physics · doi:10.1007/bf00654826 · Cited by 261
Research works printed but not linked: 30
- 1980, Postepy Fiz. Med., 15, 201
- 1975, IEEE Trans. Magn., MAG-11, 694
- 1981, IEEE Trans. Magn., MAG-17, 849
- 1972, Lyon. Med., 228, 13
- 1974, J. Physiol. (Paris), 69, 179
- 1979, Adv. Cardiovasc. Phys., 2, 1
- 1980, Ann. Occup. Hyg., 23, 173
- 1969, Phys. Lett., 28A, 638
- 1979, IEEE Trans. Magn., MAG-15, 474
- 1981, Physics, 107B, 29
- 1981, IEEE Trans. Magn., MAG-17, 400
- 1978, Ann. Clin. Res., 10, 1
- 1981, Electroencephalogr. Clin. Neurophysiol., 52, 151
- 1974, IEEE Trans. Magn., MAG-9, 536
- 1978, J. Phys. (Paris), 39, C6
- 1982, Can. J. Phys., 60, 1
- 1977, IEEE Trans. Magn., MAG-13, 365
- 1982, IEEE Trans. Magn., MAG-18, 260
- 1981, Phys. Lett., 82A, 57
- 1967, Phys. Lett., 24A, 736
- 1968, Phys. Lett., 27A, 670
- 1982, Physica, 109 & 110B, 2001
- 1974, AIP Conf. Proc., 18, 1335
- 1981, App. Phys. Commun., 1, 1
- 1980, IEEE Trans. Magn., MAG-16, 818
- 1978, Clin. Res., 26, 504A
- 1981, Physica, 107B, 27
- 1978, J. Phys. (Paris), 39, C6
- 1979, IEEE Trans. Magn., MAG-15, 478
- 1974, Electron. Des., 16, 96
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Superconducting quantum interference device instruments and applications
Fagaly, R. L. (2006) · Review of Scientific Instruments · doi:10.1063/1.2354545 · Cited by 594
Tonotopic Organization of the Human Auditory Cortex
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Science · doi:10.1126/science.7079770 · Cited by 486
Self-citationUsing a magnetometer to image a two-dimensional current distribution
Roth, B. J., Sepulveda, N. G., & Wikswo, J. P. (1989) · Journal of Applied Physics · doi:10.1063/1.342549 · Cited by 462
Integrated semiconductor magnetic field sensors
Baltes, H., & Popović, R. S. (1986) · Proceedings of the IEEE · doi:10.1109/proc.1986.13597 · Cited by 346
Uniform magnetic field produced by three, four, and five square coils
Merritt, R., Purcell, C., & Stroink, G. (1983) · Review of Scientific Instruments · doi:10.1063/1.1137480 · Cited by 332
Žutić, I., Matos-Abiague, A., Scharf, B., Dery, H., & Belashchenko, K. (2019) · Materials Today · doi:10.1016/j.mattod.2018.05.003 · Cited by 301
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300
Wang, J.-Z., Williamson, S. J., & Kaufman, L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142641 · Cited by 299
Self-citationThe hippocampal formation as a source of the slow endogenous potentials
Okada, Y. C., Kaufman, L., & Williamson, S. J. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90130-x · Cited by 297
Self-citationWikswo, J. P. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.402511 · Cited by 201
Barth, D. S., Sutherling, W., Engle, J., & Beatty, J. (1984) · Science · doi:10.1126/science.6422552 · Cited by 199
Recording and Interpretation of Cerebral Magnetic Fields
Hari, R., & Lounasmaa, O. V. (1989) · Science · doi:10.1126/science.2655083 · Cited by 184
Spatial resolution of neuromagnetic records: theoretical calculations in a spherical model
Hari, R., Joutsiniemi, S.-L., & Sarvas, J. (1988) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(88)90020-2 · Cited by 181
Principles and applications of SQUIDs
Clarke, J. (1989) · Proceedings of the IEEE · doi:10.1109/5.34120 · Cited by 151
Neuromagnetic investigation of somatotopy of human hand somatosensory cortex
Baumgartner, C., Doppelbauer, A., Deecke, L., Barth, D. S., Zeitlhofer, J., Lindinger, G., & Sutherling, W. W. (1991) · Experimental Brain Research · doi:10.1007/bf00227089 · Cited by 147
SQUID systems for biomagnetic imaging
Pizzella, V., Penna, S. D., Gratta, C. D., & Romani, G. L. (2001) · Superconductor Science and Technology · doi:10.1088/0953-2048/14/7/201 · Cited by 143
Self-citationCharacterization of the human auditory cortex by the neuromagnetic method
Romani, G. L., Williamson, S. J., Kaufman, L., & Brenner, D. A. (1982) · Experimental Brain Research · doi:10.1007/bf00239356 · Cited by 143
Self-citationNovel approaches to low‐cost MRI
Macovski, A., & Conolly, S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300211 · Cited by 140
Analysis of the Electromagnetic Signals of the Human Brain: Milestones, Obstacles, and Goals
Gevins, A. S. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325246 · Cited by 136
Neuromagnetic studies of somatosensory system: Principles and examples
Hari, R., & Kaukoranta, E. (1985) · Progress in Neurobiology · doi:10.1016/0301-0082(85)90007-3 · Cited by 135
Magnetic localization of a dipolar current source implanted in a sphere and a human cranium
Barth, D. S., Sutherling, W. W., Broffman, J., & Beatty, J. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90094-5 · Cited by 134
Magnetoencephalography and Epilepsy Research
Rose, D. F., Smith, P. D., & Sato, S. (1987) · Science · doi:10.1126/science.3310234 · Cited by 124
Large-area low-noise seven-channel dc SQUID magnetometer for brain research
Knuutila, J., Ahlfors, S. P., Ahonen, A. I., Hallstrom, J. K., Kajola, M., Lounasmaa, O. V., Vilkman, V., & Tesche, C. D. (1987) · Review of Scientific Instruments · doi:10.1063/1.1139478 · Cited by 123
The magnetic field of complex partial seizures agrees with intracranial localizations
Sutherling, W. W., Crandall, P. H., Engel, J., Darcey, T. M., Cahan, L. D., & Barth, D. S. (1987) · Annals of Neurology · doi:10.1002/ana.410210605 · Cited by 119
Selective localization of alpha brain activity with neuromagnetic measurements
Chapman, R. M., Ilmoniemi, R. J., Barbanera, S., & Romani, G. L. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90047-6 · Cited by 115
Self-citationLittle, W. A. (1984) · Review of Scientific Instruments · doi:10.1063/1.1137820 · Cited by 114
Sutherling, W. W., & Barth, D. S. (1989) · Annals of Neurology · doi:10.1002/ana.410250409 · Cited by 114
The Impact of High-Temperature Superconductivity on SQUID Magnetometers
Clarke, J., & Koch, R. H. (1988) · Science · doi:10.1126/science.242.4876.217 · Cited by 104
Clarke, J. (1996) · Springer eBooks · doi:10.1007/978-94-011-5674-5_1 · Cited by 94
Localization of magnetic interictal discharges in temporal lobe epilepsy
Rose, D. F., Sato, S., Smith, P. D., Porter, R. J., Theodore, W. H., Friauf, W. S., Bonner, R. F., & Jabbari, B. (1987) · Annals of Neurology · doi:10.1002/ana.410220311 · Cited by 81
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
AC biosusceptometry in the study of drug delivery
Corá, L. A., Romeiro, F. G., Stelzer, M., Américo, M. F., de Oliveira, R. B., Baffa, O., & Miranda, J. R. D. A. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.01.026 · Cited by 78
Spatiotemporal modeling of cerebral evoked magnetic fields to median nerve stimulation
Baumgartner, C., Sutherling, W. W., Di, S., & Barth, D. S. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90153-u · Cited by 73
A four-channel squid magnetometer for brain research
Ilmoniemi, R. J., Hari, R., & Reinikainen, K. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90143-3 · Cited by 70
Thin Film Magnetoelectric Sensors Toward Biomagnetism: Materials, Devices, and Applications
Dong, C., Liang, X., Gao, J., Chen, H., He, Y., Wei, Y., Zaeimbashi, M., Matyushov, A. D., Sun, C., & Sun, N. X. (2022) · Advanced Electronic Materials · doi:10.1002/aelm.202200013 · Cited by 69
Biomagnetism: The First Sixty Years
Roth, B. J. (2023) · Sensors · doi:10.3390/s23094218 · Cited by 66
Evoked α- and μ-rhythm in humans: a neuromagnetic study
Narici, L., Pizzella, V., Romani, G. L., Torrioli, G., Traversa, R., & Rossini, P. M. (1990) · Brain Research · doi:10.1016/0006-8993(90)91709-p · Cited by 59
Self-citationStudy of focal epilepsy by multichannel neuromagnetic measurements
Ricci, G., Romani, G. L., Salustri, C., Pizzella, V., Torrioli, G., Buonomo, S., Peresson, M., & Modena, I. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90204-5 · Cited by 54
Self-citationNeuromagnetic functional localization: principles, state of the art, and perspectives
Romani, G. L., & Rossini, P. (1988) · Brain Topography · doi:10.1007/bf01129335 · Cited by 51
Self-citationCurrent source-density and neuromagnetic analysis of the direct cortical response in rat cortex
Barth, D. S., & Sutherling, W. W. (1988) · Brain Research · doi:10.1016/0006-8993(88)91567-3 · Cited by 50
Maclin, E. L., Okada, Y. C., Kaufman, L., & Williamson, S. J. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455941 · Cited by 49
Self-citationSQUID technology applied to the study of electrochemical corrosion
Bellingham, J. G., MacVicar, M. L. A., & Nisenoff, M. (1987) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1987.1065035 · Cited by 48
Fast and Slow Magnetic Phenomena in Focal Epileptic Seizures
Barth, D. S., Sutherling, W. W., & Beatty, J. (1984) · Science · doi:10.1126/science.6436979 · Cited by 46
Clarke, J. (1993) · Springer eBooks · doi:10.1007/978-94-011-1918-4_5 · Cited by 45
Integrated LTc-SQUID magnetometers for multichannel systems
Granata, C., Russo, C. D., Monaco, A., & Russo, M. (2001) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.919293 · Cited by 45
Magnetic shield for wide-bandwidth magnetic measurements for nondestructive testing and biomagnetism
Ma, Y. P., & Wikswo, J. P. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142195 · Cited by 45
Focus on SQUIDs in Biomagnetism
Clarke, J., Lee, Y., & Schneiderman, J. F. (2018) · Superconductor Science and Technology · doi:10.1088/1361-6668/aacb14 · Cited by 44
Erne, S., Narici, L., Pizzella, V., & Romani, G. (1987) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1987.1064889 · Cited by 43
Self-citationClarke, J. (1989) · Springer eBooks · doi:10.1007/978-3-642-83885-9_5 · Cited by 43
Tsukada, K., Kandori, A., Miyashita, T., Sasabuti, H., Suzuki, H., Kondo, S., Komiyama, Y., & Teshigawara, K. (2002) · Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286) · doi:10.1109/iembs.1998.745962 · Cited by 42
Application of VCSEL in Bio-Sensing Atomic Magnetometers
Zhou, P., Quan, W., Wei, K., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12121098 · Cited by 42
Technique for measuring the ac susceptibility of portions of the human body or other large objects
Bastuscheck, C. M., & Williamson, S. J. (1985) · Journal of Applied Physics · doi:10.1063/1.335609 · Cited by 42
Self-citationWikswo, J. P., & Roth, B. J. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90135-6 · Cited by 41
Detection of Magnetic Fields Generated by Electrochemical Corrosion
Bellingham, J. G., MacVicar, M. L. A., Nisenoff, M., & Searson, P. C. (1986) · Journal of The Electrochemical Society · doi:10.1149/1.2109010 · Cited by 40
Measurement of segmental transit through the gut in man: A novel approach by the biomagnetic method
Basile, M., Neri, M., Carriero, A., Casciardi, S., Comani, S., Gratta, C. D., Donato, L., Luzio, S. D., Macrì, M. A., Pasquarelli, A., et al. (1992) · Digestive Diseases and Sciences · doi:10.1007/bf01296499 · Cited by 39
Self-citation28-channel hybrid system for neuromagnetic measurements
Foglietti, V., Gratta, C. D., Pasquarelli, A., Pizzella, V., Torrioli, G., Romani, G. L., Gallagher, W. J., Ketchen, M. B., Kleinsasser, A. W., & Sandstrom, R. L. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133831 · Cited by 39
Self-citationNeuromagnetic field modeling of multiple brain regions producing interictal spikes in human epilepsy
Barth, D. S., Baumgartner, C., & Sutherling, W. W. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90088-6 · Cited by 38
Application of SQUID sensors to the investigation of neural activity in the human brain
Williamson, S. J., & Kaufman, L. (1983) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1983.1062555 · Cited by 38
Self-citationEvaluation of a high-performance magnetically shielded room for biomagnetic measurement
Harakawa, K., Kajiwara, G., Kazami, K., OGATA, H., & Kado, H. (1996) · IEEE Transactions on Magnetics · doi:10.1109/20.545761 · Cited by 37
Rossini, P. M., Narici, L., Romani, G. L., Traversa, R., Cecchi, L., Cilli, M., & Urbano, A. (1989) · International Journal of Neuroscience · doi:10.3109/00207458908991617 · Cited by 36
Self-citationNoninvasive localization of accessory pathways by magnetocardiographic imaging
Nomura, M., Nakaya, Y., Saito, K., Kishi, F., Watatsuki, T., Miyoshi, H., Nishikado, A., Bando, S., Ito, S., Nlshltanl, H., et al. (1994) · Clinical Cardiology · doi:10.1002/clc.4960170504 · Cited by 35
Magnetic field associated with neural activities in an isolated cerebellum
Okada, Y. C., Lauritzen, M., & Nicholson, C. (1987) · Brain Research · doi:10.1016/0006-8993(87)91451-x · Cited by 35
Magnetic detection of sleep spindles in normal subjects
Nakasato, N., Kado, H., Nakanishi, M., Koyanagi, M., Kasai, N., Niizuma, H., & Yoshimoto, T. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90210-b · Cited by 33
A biomagnetic method for studying gastro-intestinal activity
Luzio, S. D., Comani, S., Romani, G. L., Basile, M., Gratta, C. D., & Pizzella, V. (1989) · Il Nuovo Cimento D · doi:10.1007/bf02459126 · Cited by 32
Self-citationChapman, R. M., Romani, G. L., Barbanera, S., Leoni, R., Modena, I., Ricci, G., & Campitelli, F. (1983) · Lettere al nuovo cimento della societa italiana di fisica/Lettere al nuovo cimento · doi:10.1007/bf02805209 · Cited by 32
Self-citationSun, J., Ren, J., Xu, X., Zhou, W., Qian, J., Wang, H., & Wang, H. (2024) · Measurement · doi:10.1016/j.measurement.2024.114594 · Cited by 31
Improvement of the properties of an eddy current magnetic shield with active compensation
Malmivuo, J. A., Lekkala, J. O., Kontro, P., Suomaa, L., & Vihinen, H. (1987) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/20/2/007 · Cited by 31
Calibration of a multichannel MEG system based on the Signal Space Separation method
Chella, F., Zappasodi, F., Marzetti, L., Penna, S. D., & Pizzella, V. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/15/4855 · Cited by 30
Double dc SQUID for flux-locked-loop operation
Foglietti, V. (1991) · Applied Physics Letters · doi:10.1063/1.105413 · Cited by 30
An Introduction to the Use of SQUID Magnetometers in Biomagnetism
Fuller, M., Goree, J., & Goodman, W. L. (1985) · Topics in geobiology · doi:10.1007/978-1-4613-0313-8_4 · Cited by 30
Recent advancements in the SQUID magnetospinogram system
Adachi, Y., Kawai, J., Haruta, Y., Miyamoto, M., Kawabata, S., Sekihara, K., & Uehara, G. (2017) · Superconductor Science and Technology · doi:10.1088/1361-6668/aa66b3 · Cited by 27
SQUIDs: Principles, Noise, and Applications
Clarke, J. (1990) · Elsevier eBooks · doi:10.1016/b978-0-12-601715-1.50006-6 · Cited by 26
SQUID arrays for simultaneous magnetic measurements: calibration and source localization performance
Ribeiro, P. C., Williamson, S. J., & Kaufman, L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.4584 · Cited by 26
Self-citationSQUID detection of electronic circuits
Fagaly, R. L. (1989) · IEEE Transactions on Magnetics · doi:10.1109/20.92514 · Cited by 25
9. Experimental Methods in Rock Magnetism and Paleomagnetism
Fuller, M. (1987) · Methods of experimental physics · doi:10.1016/s0076-695x(08)60590-6 · Cited by 25
Tsukada, K., Mitsui, T., Terada, Y., Horigome, H., & Yamaguchi, I. (1999) · Journal of Electrocardiology · doi:10.1016/s0022-0736(99)90001-8 · Cited by 25
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Wang, J.-Z., Kaufman, L., & Williamson, S. J. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90065-4 · Cited by 24
Self-citationIntegrated DC–SQUID Magnetometer
Nakanishi, M., Koyanagi, M., Kosaka, S., Shoji, A., Aoyagi, M., & Shinoki, F. (1987) · Japanese Journal of Applied Physics · doi:10.1143/jjap.26.1050 · Cited by 23
Nomura, M., Fujino, K., Katayama, M., Takeuchi, A., Fukuda, Y., Sumi, M., Murakami, M., Nakaya, Y., & Mori, H. (1988) · Journal of Electrocardiology · doi:10.1016/s0022-0736(88)80014-1 · Cited by 23
Biomagnetism: An application of squid sensors to medicine and physiology
Romani, G. L. (1984) · Physica B+C · doi:10.1016/0378-4363(84)90147-5 · Cited by 23
Self-citationSimplified fast method for magnetic characteristics measurement of the HTc superconducting materials
Zrubec, V., Cigáň, A., & Maňka, J. (1994) · Physica C Superconductivity · doi:10.1016/0921-4534(94)90699-8 · Cited by 22
Chapter 5: Multi-Squid Devices and Their Applications
Ilmoniemi, R. J., Knuutila, J., Ryhänen, T., & Seppä, H. (1989) · Progress in low temperature physics · doi:10.1016/s0079-6417(08)60044-x · Cited by 22
Applications of SQUID Magnetometers to Biomagnetism and Nondestructive Evaluation
Wikswo, J. P. (2000) · Springer eBooks · doi:10.1007/978-94-017-0752-7_3 · Cited by 20
New technologies: nuclear quadrupole resonance as an explosive and narcotic detection technique
Гречишкин, В. С., & Sinyavskii, N. Y. (1997) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0167.199704d.0413 · Cited by 20
Discrete spatial filtering with SQUID gradiometers in biomagnetism
Bruno, A. C., Ribeiro, P. C., von der Weid, J. P., & Symko, O. G. (1986) · Journal of Applied Physics · doi:10.1063/1.337008 · Cited by 20
Effects of detector coil size and configuration on measurements of the magnetoencephalogram
Cuffin, B. N., & Cohen, D. (1983) · Journal of Applied Physics · doi:10.1063/1.332428 · Cited by 20
Multichannel Instrumentation for Biomagnetism
Foglietti, V. (1992) · Springer proceedings in physics · doi:10.1007/978-3-642-77457-7_85 · Cited by 20
Kaufman, L., Okada, Y. C., TRIPP, J., & Weinberg, H. (1984) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1984.tb23596.x · Cited by 20
Self-citationNarici, L., Romani, G. L., Salustri, C., Pizzella, V., Modena, I., & Papanicolaou, A. C. (1987) · International Journal of Neuroscience · doi:10.3109/00207458709043337 · Cited by 20
Self-citationNarici, L., Romani, G. L., Salustri, C., Pizzella, V., Torrioli, G., & Modena, I. (1987) · International Journal of Neuroscience · doi:10.3109/00207458709043338 · Cited by 20
Self-citationPhase-Modulated Cavity Magnon Polaritons as a Precise Magnetic Field Probe
Crescini, N., Carugno, G., & Ruoso, G. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.16.034036 · Cited by 19
Apodized pickup coils for improved spatial resolution of SQUID magnetometers
Roth, B. J., & Wikswo, J. P. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141336 · Cited by 19
Yokosawa, K., & Kuriki, S. (1994) · Review of Scientific Instruments · doi:10.1063/1.1145170 · Cited by 17
Problems in coupling a dc-SQUID to the external world
Carelli, P., & Foglietti, V. (1985) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1985.1063732 · Cited by 17
Seki, Y., & Kandori, A. (2007) · Japanese Journal of Applied Physics · doi:10.1143/jjap.46.3397 · Cited by 16
A new method for magnetoencephalography: a three-dimensional magnetometer-spatial filter system
Toyama, K., Yoshikawa, K., Yoshida, Y., Kondo, Y., Tomita, S., Takanashi, Y., Ejima, Y., & Yoshizawa, S. (1999) · Neuroscience · doi:10.1016/s0306-4522(98)00629-0 · Cited by 16
Magnetoencephalography in clinical epileptology and Epilepsy research
Baumgartner, C., & Deecke, L. (1990) · Brain Topography · doi:10.1007/bf01140589 · Cited by 16
Sakakibara, M., Uehara, G., & Adachi, Y. (2021) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2021.3085305 · Cited by 15
Metadata
- Authors
- Romani, G. L., Williamson, S. J., & Kaufman, L.
- Affiliations
- New York University (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1982-12-01
- Volume
- 53
- Issue
- 12
- Pages
- 1815-1845
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W4238293271
- Cited by
- 235
- References
- 83
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 7 · 2023: 3 · 2022: 5 · 2021: 3 · 2019: 2 · 2018: 3 · 2017: 1 · 2016: 3 · 2015: 3 · 2014: 2 · 2013: 1 · 2012: 2
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- magnetic field measurement, squid, field sensors, unshielded environment, biological systems
- MeSH terms
- Body Burden, Brain, Dust, Electromagnetic Fields, Environmental Exposure, Heart, Humans, Ions, Lung, Magnetics, Retina, Electromagnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.