The DOI matches its Crossref record.
Detection of mercury vapor using resonating microcantilevers
Abstract
Oscillating silicon nitride microcantilevers coated with a thin gold film have been used to detect mercury vapor in air. Cantilever resonance frequency changes due to surface mass loading as a result of adsorption of mercury vapor. Furthermore, cantilever bending is also altered due to changes in surface stress induced by mercury adsorption on the gold overlayer. Both of these phenomena can be used to quantitatively detect adsorbed vapors with picogram mass resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ekinci, K. L., & Roukes, M. L. (2005) · Review of Scientific Instruments · doi:10.1063/1.1927327 · Cited by 1,374
Weighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Zeptogram-Scale Nanomechanical Mass Sensing
Yang, Y. T., Callegari, C., Feng, X. L., Ekinci, K. L., & Roukes, M. L. (2006) · Nano Letters · doi:10.1021/nl052134m · Cited by 1,041
Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems
Ekinci, K. L., Yang, Y. T., & Roukes, M. L. (2004) · Journal of Applied Physics · doi:10.1063/1.1642738 · Cited by 695
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Ultrasensitive Mass Sensing with a Nanotube Electromechanical Resonator
Lassagne, B., Garcia-Sanchez, D., Aguasca, A., & Bachtold, A. (2008) · Nano Letters · doi:10.1021/nl801982v · Cited by 407
Microcantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Femtogram mass detection using photothermally actuated nanomechanical resonators
Lavrik, N. V., & Datskos, P. G. (2003) · Applied Physics Letters · doi:10.1063/1.1569050 · Cited by 308
Narita, F., Wang, Z., Kurita, H., Li, Z., Shi, Y., Jia, Y., & Soutis, C. (2021) · Advanced Materials · doi:10.1002/adma.202005448 · Cited by 263
Metadata
- Authors
- Thundat, T., Wachter, E. A., Sharp, S. L., & Warmack, R. J.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1995-03-27
- Volume
- 66
- Issue
- 13
- Pages
- 1695-1697
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1994151002
- Cited by
- 436
- References
- 0
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.