An in-situ hot stage for temperature-dependent tapping-mode™ atomic force microscopy
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Tapping-mode atomic force microscopy (TM-AFM) is a widely used method for the study of the nanometer scale morphology of soft materials such as biological samples and polymers. Many of these materials have structures and properties which are a sensitive function of temperature even below 100 °C making the control of temperature in such an instrument quite valuable. This paper describes the construction of a heater for a commercial TM-AFM which can reach surface temperatures as high as 100 °C. Temperature variations affect many experimental parameters in an atomic force microscope, and to compare images collected at different temperatures it is critical to evaluate these instrumental effects. In particular, the cantilever resonance frequency decreases as samples become hot; this effect is easily corrected by frequently resetting the drive frequency at high temperatures. As an example of the utility of this technique images of the nanoscale changes that occur prior to the bulk melting of paraffin crystals are presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Phase imaging and stiffness in tapping-mode atomic force microscopy
Magonov, S. N., Elings, V., & Whangbo, M.-H. (1997) · Surface Science · doi:10.1016/s0039-6028(96)01591-9 · Cited by 1,020
From Molecules to Cells: Imaging Soft Samples with the Atomic Force Microscope
Radmacher, M., Tillmann, R. W., Fritz, M., & Gaub, H. E. (1992) · Science · doi:10.1126/science.1411505 · Cited by 900
Rotator phases of the normal alkanes: An x-ray scattering study
Sirota, E. B., King, H. E., Singer, D. M., & Shao, H. H. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464874 · Cited by 448
CHARACTERIZATION OF POLYMER SURFACES WITH ATOMIC FORCE MICROSCOPY
Magonov, S. N., & Reneker, D. H. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.175 · Cited by 444
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
Bar, G., Thomann, Y., Brandsch, R., Cantow, H.-J., & Whangbo, M.-H. (1997) · Langmuir · doi:10.1021/la970091m · Cited by 324
Burnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D. (1997) · Nanotechnology · doi:10.1088/0957-4484/8/2/004 · Cited by 265
Anczykowski, B., Krüger, D., Babcock, K. L., & Fuchs, H. (1996) · Ultramicroscopy · doi:10.1016/s0304-3991(97)00002-8 · Cited by 165
Brandsch, R., Bar, G., & Whangbo, M.-H. (1997) · Langmuir · doi:10.1021/la970822i · Cited by 161
Research works printed but not linked: 3
- 1993, Surf. Sci., 290, L688
- 1995, Nanotechnology, 8, 40
- 1997, Ann. Phys. (Leipzig), 6, 341
Cited by
High temperature nanoindentation: The state of the art and future challenges
Wheeler, J. M., Armstrong, D. E. J., Heinz, W., & Schwaiger, R. (2015) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2015.02.002 · Cited by 264
High temperature surface imaging using atomic force microscopy
Broekmaat, J. J., Brinkman, A., Blank, D. H. A., & Rijnders, G. J. H. M. (2008) · Applied Physics Letters · doi:10.1063/1.2836943 · Cited by 28
Macleod, J. M., & Rosei, F. (2011) · Australian Journal of Chemistry · doi:10.1071/ch11151 · Cited by 19
Simple low-drift heating stage for scanning probe microscopes
Oulevey, F., Gremaud, G., Kulik, A. J., & Guisolan, B. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149689 · Cited by 19
Variable temperature fluid stage for atomic force microscopy
Workman, R. K., & Manne, S. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150219 · Cited by 18
Hwu, E., Nazaretski, E., Chu, Y. S., Chen, H.-H., Chen, Y.-S., Xu, W., & Hwu, Y. (2013) · Review of Scientific Instruments · doi:10.1063/1.4838635 · Cited by 17
Tripathi, M., Paolicelli, G., D’Addato, S., & Valeri, S. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/24/245706 · Cited by 16
Wu, Y., Hansen, K. V., Jacobsen, T., & Mogensen, M. B. (2011) · Solid State Ionics · doi:10.1016/j.ssi.2011.06.017 · Cited by 14
Scanning Probe Microscopy at 650°C in Air
Hansen, K. V., Jacobsen, T., Nørgaard, A., Ohmer, N., & Mogensen, M. B. (2009) · Electrochemical and Solid-State Letters · doi:10.1149/1.3183881 · Cited by 14
Construction and characterization of a heating stage for a scanning probe microscope up to 215 °C
Xie, Z., Luo, E. Z., Xu, J., Wilson, I. H., Zhao, L., & Zhang, X. X. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150587 · Cited by 12
Palacios, J. K., Zhang, H., Zhang, B., Hadjichristidis, N., & Müller, A. J. (2020) · Polymer · doi:10.1016/j.polymer.2020.122863 · Cited by 11
A hot tip: imaging phenomena using in situ multi-stimulus probes at high temperatures
Nonnenmann, S. S. (2016) · Nanoscale · doi:10.1039/c5nr08172f · Cited by 11
A replaceable, low thermal mass hot stage for scanning probe microscopy
Trawick, M. L., Angelescu, D. E., Chaikin, P. M., Valenti, M. J., & Register, R. A. (2003) · Review of Scientific Instruments · doi:10.1063/1.1539892 · Cited by 11
Controlled Atmosphere High Temperature SPM for electrochemical measurements
Hansen, K. V., Sander, C., Koch, S., & Mogensen, M. B. (2007) · Journal of Physics Conference Series · doi:10.1088/1742-6596/61/1/078 · Cited by 8
Tranchida, D., Kandioller, G., Schwarz, P., Schaffer, W., & Gahleitner, M. (2020) · Polymer Crystallization · doi:10.1002/pcr2.10140 · Cited by 7
Simple, cost effective, in situ sample hot stage for biological atomic force microscopy
Sattin, B. D., & Goh, M. C. (2004) · Review of Scientific Instruments · doi:10.1063/1.1809290 · Cited by 7
Park, C., Shultz, T. E., & Dutta, I. (2004) · Review of Scientific Instruments · doi:10.1063/1.1809262 · Cited by 7
Fast heating stage for open liquid-cell atomic force microscopy
Kim, Y., Choi, I., Kang, S. K., Lee, J., & Yi, J. (2006) · Review of Scientific Instruments · doi:10.1063/1.2186254 · Cited by 4
Liu, X. (2017) · theses.fr (ABES) · doi:10.70675/084cb367zdaf6z40dcz89bcz28bac51413e6 · Cited by 4
Thermoelectric stack sample cooling modification of a commercial atomic force microscopy
del Moral, A., Gonzalez‐Rosillo, J. C., Gómez, A., Puig, T., & Obradors, X. (2018) · Ultramicroscopy · doi:10.1016/j.ultramic.2018.10.014 · Cited by 3
In-situ growth monitoring with scanning force microscopy during pulsed laser deposition
Broekmaat, J. J. (2008) · doi:10.3990/1.9789036526555 · Cited by 2
Metadata
- Authors
- Prilliman, S. G., Kavanagh, A. M., Scher, E. C., Robertson, S. T., Hwang, K. S., & Colvin, V. L.
- Affiliations
- Rice University (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1998-09-01
- Volume
- 69
- Issue
- 9
- Pages
- 3245-3250
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2010137156
- Cited by
- 19
- References
- 28
- Citations by year
- 2020: 2 · 2018: 1 · 2016: 1 · 2015: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Nanofabrication and Lithography Techniques
- Keywords
- tapping mode atomic force microscopy, in situ heating, cantilever resonance frequency, soft materials, polymers, biological specimen
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.