An in-situ hot stage for temperature-dependent tapping-mode™ atomic force microscopy
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Tapping-mode atomic force microscopy (TM-AFM) is a widely used method for the study of the nanometer scale morphology of soft materials such as biological samples and polymers. Many of these materials have structures and properties which are a sensitive function of temperature even below 100 °C making the control of temperature in such an instrument quite valuable. This paper describes the construction of a heater for a commercial TM-AFM which can reach surface temperatures as high as 100 °C. Temperature variations affect many experimental parameters in an atomic force microscope, and to compare images collected at different temperatures it is critical to evaluate these instrumental effects. In particular, the cantilever resonance frequency decreases as samples become hot; this effect is easily corrected by frequently resetting the drive frequency at high temperatures. As an example of the utility of this technique images of the nanoscale changes that occur prior to the bulk melting of paraffin crystals are presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Phase imaging and stiffness in tapping-mode atomic force microscopy
Magonov, S. N., Elings, V., & Whangbo, M.-H. (1997) · Surface Science · doi:10.1016/s0039-6028(96)01591-9 · Cited by 1,020
From Molecules to Cells: Imaging Soft Samples with the Atomic Force Microscope
Radmacher, M., Tillmann, R. W., Fritz, M., & Gaub, H. E. (1992) · Science · doi:10.1126/science.1411505 · Cited by 900
Rotator phases of the normal alkanes: An x-ray scattering study
Sirota, E. B., King, H. E., Singer, D. M., & Shao, H. H. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464874 · Cited by 448
CHARACTERIZATION OF POLYMER SURFACES WITH ATOMIC FORCE MICROSCOPY
Magonov, S. N., & Reneker, D. H. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.175 · Cited by 444
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
Bar, G., Thomann, Y., Brandsch, R., Cantow, H.-J., & Whangbo, M.-H. (1997) · Langmuir · doi:10.1021/la970091m · Cited by 324
Burnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D. (1997) · Nanotechnology · doi:10.1088/0957-4484/8/2/004 · Cited by 265
Anczykowski, B., Krüger, D., Babcock, K. L., & Fuchs, H. (1996) · Ultramicroscopy · doi:10.1016/s0304-3991(97)00002-8 · Cited by 165
Brandsch, R., Bar, G., & Whangbo, M.-H. (1997) · Langmuir · doi:10.1021/la970822i · Cited by 161
Two-Dimensional Melting of an Anisotropic Crystal Observed at the Molecular Level
Sikes, H. D., & Schwartz, D. K. (1997) · Science · doi:10.1126/science.278.5343.1604 · Cited by 148
Forces affecting the substrate in resonant tapping force microscopy
Spatz, J. P., Sheiko, S. S., Möller, M., Winkler, R. G., Reineker, P., & Marti, O. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/2/002 · Cited by 148
AFM study of thermotropic structural transitions in poly(diethylsiloxane)
Magonov, S., Elings, V. B., & Papkov, V. S. (1997) · Polymer · doi:10.1016/s0032-3861(96)00513-7 · Cited by 145
A scanning force microscope with atomic resolution in ultrahigh vacuum and at low temperatures
Allers, W., Schwarz, A., Schwarz, U. D., et al. (1998) · Review of Scientific Instruments · doi:10.1063/1.1148499 · Cited by 116
Driven nonlinear atomic force microscopy cantilevers: From noncontact to tapping modes of operation
Sarid, D., Ruskell, T. G., Workman, R. K., et al. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.589163 · Cited by 91
Bottomley, L. A., Coury, J. E., & First, P. N. (1996) · Analytical Chemistry · doi:10.1021/a1960008+ · Cited by 90
Morphology and mechanical properties of polymer surfaces via scanning force microscopy
Kajiyama, T., Tanaka, K., Ge, S., & Takahara, A. (1996) · Progress in Surface Science · doi:10.1016/0079-6816(96)00006-8 · Cited by 82
The observation of spiral growth-steps in n -paraffin single crystals in the electron microscope
Dawson, I. M. P., & Vand, V. (1951) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1951.0088 · Cited by 68
Biological cryo atomic force microscopy: a brief review
Shao, Z., & Zhang, Y. (1996) · Ultramicroscopy · doi:10.1016/s0304-3991(96)00087-3 · Cited by 56
Physical properties of dynamic force microscopies in contact and noncontact operation
Krüger, D., Anczykowski, B., & Fuchs, H. (1997) · Annalen der Physik · doi:10.1002/andp.19975090502 · Cited by 52
Improvement of thermally induced bending of cantilevers used for atomic force microscopy
Radmacher, M., Cleveland, J. P., & Hansma, P. K. (1995) · Scanning · doi:10.1002/sca.4950170208 · Cited by 47
Temperature controlled microstage for an atomic force microscope
Mus̆evic̆, I., Slak, G., & Blinc, R. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147212 · Cited by 46
Fiber interferometer-based variable temperature scanning force microscope
Euler, R., Memmert, U., & Hartmann, U. H. (1997) · Review of Scientific Instruments · doi:10.1063/1.1147992 · Cited by 31
Effects of sample heating in FT-Raman spectra of biological materials
Marigheto, N., Kemsley, E. K., Potter, J., et al. (1996) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/0584-8539(96)01732-1 · Cited by 31
Scanning force microscope and vacuum chamber for the study of ice films: Design and first results
Bluhm, H., Pan, S. H., Xu, L., et al. (1998) · Review of Scientific Instruments · doi:10.1063/1.1148841 · Cited by 26
Shealy, J. R., & Wicks, G. W. (1987) · Applied Physics Letters · doi:10.1063/1.97953 · Cited by 26
Scanning force microscopy: new instrumentation and applications
Zasadzinski, J. A. (1996) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(96)80014-8 · Cited by 14
Bækmark, T. R., Bjørnholm, T., & Mouritsen, O. G. (1997) · Review of Scientific Instruments · doi:10.1063/1.1147849 · Cited by 11
Research works printed but not linked: 3
- 1993, Surf. Sci., 290, L688
- 1995, Nanotechnology, 8, 40
- 1997, Ann. Phys. (Leipzig), 6, 341
Cited by
Palacios, J. K., Zhang, H., Zhang, B., Hadjichristidis, N., & Müller, A. J. (2020) · Polymer · doi:10.1016/j.polymer.2020.122863 · Cited by 11
Metadata
- Authors
- Prilliman, S. G., Kavanagh, A. M., Scher, E. C., Robertson, S. T., Hwang, K. S., & Colvin, V. L.
- Affiliations
- Rice University (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1998-09-01
- Volume
- 69
- Issue
- 9
- Pages
- 3245-3250
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2010137156
- Cited by
- 19
- References
- 28
- Citations by year
- 2020: 2 · 2018: 1 · 2016: 1 · 2015: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Nanofabrication and Lithography Techniques
- Keywords
- tapping mode atomic force microscopy, in situ heating, cantilever resonance frequency, soft materials, polymers, biological specimen
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.