The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Development of low noise cantilever deflection sensor for multienvironment frequency-modulation atomic force microscopy
Open accessAbstract
We have developed a low noise cantilever deflection sensor with a deflection noise density of 17fm∕Hz by optimizing the parameters used in optical beam deflection (OBD) method. Using this sensor, we have developed a multienvironment frequency-modulation atomic force microscope (FM-AFM) that can achieve true molecular resolution in various environments such as in moderate vacuum, air, and liquid. The low noise characteristic of the deflection sensor makes it possible to obtain a maximum frequency sensitivity limited by the thermal Brownian motion of the cantilever in every environment. In this paper, the major noise sources in OBD method are discussed in both theoretical and experimental aspects. The excellent noise performance of the deflection sensor is demonstrated in deflection and frequency measurements. True molecular-resolution FM-AFM images of a polydiacetylene single crystal taken in vacuum, air, and water are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Review of Progress in Quantitative Nondestructive Evaluation: Volume 15A
(1996) · Springer eBooks · doi:10.1007/978-1-4613-0383-1 · Cited by 1,963
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
Atomic Resolution of the Silicon (111)-(7×7) Surface by Atomic Force Microscopy
Giessibl, F. J. (1995) · Science · doi:10.1126/science.267.5194.68 · Cited by 1,189
Scanning force microscopy - With Applications to Electric, Magnetic and Atomic Forces
Sarid, D., Coratger, R., Ajustron, F., & Beauvillain, J. (1991) · Microscopy Microanalysis Microstructures · doi:10.1051/mmm:0199100206064900 · Cited by 563
Force microscopy with a bidirectional capacitance sensor
Neubauer, G., Cohen, S. R., McClelland, G. M., Horne, D., & Mate, C. M. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141354 · Cited by 188
Analog frequency modulation detector for dynamic force microscopy
Kobayashi, K., Yamada, H., Itoh, H., et al. (2001) · Review of Scientific Instruments · doi:10.1063/1.1416104 · Cited by 138
Self-citationFukui, K., Ōnishi, H., & Iwasawa, Y. (1997) · Chemical Physics Letters · doi:10.1016/s0009-2614(97)01143-3 · Cited by 103
Cited by
AFM-IR: Technology and Applications in Nanoscale Infrared Spectroscopy and Chemical Imaging
Dazzi, A., & Prater, C. B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00448 · Cited by 1,082
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
Self-citationFukuma, T., Ueda, Y., Yoshioka, S., & Asakawa, H. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.016101 · Cited by 464
Self-citationFukuma, T., Reischl, B., Kobayashi, N., Spijker, P., Canova, F. F., Miyazawa, K., & Foster, A. S. (2015) · Physical Review B · doi:10.1103/physrevb.92.155412 · Cited by 126
Self-citationMiyata, K., Tracey, J., Miyazawa, K., Haapasilta, V., Spijker, P., Kawagoe, Y., Foster, A. S., Tsukamoto, K., & Fukuma, T. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b00757 · Cited by 86
Self-citation
Metadata
- Authors
- Fukuma, T., Kimura, M., Kobayashi, K., Matsushige, K., & Yamada, H.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2005-04-15
- Volume
- 76
- Issue
- 5
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1993340146
- Cited by
- 387
- References
- 11
- FWCI
- 8.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of low noise cantilever deflection sensor for multienvironment frequency-modulation atomic force microscopy. https://app.cochat.ai/papers/10.1063/1.1896938
- The paper
- Fukuma, T., Kimura, M., Kobayashi, K., Matsushige, K., & Yamada, H. (2005). Development of low noise cantilever deflection sensor for multienvironment frequency-modulation atomic force microscopy. Review of Scientific Instruments. https://doi.org/10.1063/1.1896938
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.