Photoacoustic Doppler flow measurement in optically scattering media
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
We recently observed the photoacoustic Doppler effect from flowing small light-absorbing particles. Here, we apply the effect to measure blood-mimicking fluid flow in an optically scattering medium. The light scattering in the medium decreases the amplitude of the photoacoustic Doppler signal but does not affect either the magnitude or the directional discrimination of the photoacoustic Doppler shift. This technology may hold promise for a new Doppler method for measuring blood flow in microcirculation with high sensitivity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the other hand, the absorption spectrum in the flow state can be extracted from the Doppler-shifted power spectra [27,38,39].”
From Multiwavelength Photoacoustic Doppler Flowmetry of Living Microalgae Cells (2024) · cites this paper as [27]
In the citing paper
“This study builds upon the foundational research on PADF, where the speed of flowing particles having parabolic flow distribution in a cylindrical tube or vessel is measured from their Doppler shift of frequencies [26,27,28,29,30,31,32].”
From Multiwavelength Photoacoustic Doppler Flowmetry of Living Microalgae Cells (2024) · cites this paper as [27]
Citations
Cites
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationLight scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
LOCALIZED FLUID FLOW MEASUREMENTS WITH AN He–Ne LASER SPECTROMETER
Yeh, Y., & Cummins, H. Z. (1964) · Applied Physics Letters · doi:10.1063/1.1753925 · Cited by 767
Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
Chen, Z., Milner, T. E., Dave, D., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000064 · Cited by 443
Properties of photon density waves in multiple-scattering media
Tromberg, B. J., Svaasand, L. O., Tsay, T.-T., & Haskell, R. C. (1993) · Applied Optics · doi:10.1364/ao.32.000607 · Cited by 225
Photoacoustic Doppler Effect from Flowing Small Light-Absorbing Particles
Fang, H., Maslov, K., & Wang, L. V. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.184501 · Cited by 171
Self-citationPhotoacoustic imaging of biological tissue with intensity-modulated continuous-wave laser
Maslov, K., & Wang, L. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904965 · Cited by 168
Self-citationHigh-frequency color flow imaging of the microcirculation
Goertz, D. E., Christopher, D. A., Yu, J. L., Kerbel, R. S., Burns, P. N., & Foster, F. S. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00101-5 · Cited by 163
Theoretical Analysis of the CW Doppler Ultrasonic Flowmeter
Brody, W. R., & Meindl, J. D. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324381 · Cited by 154
Research works printed but not linked: 1
- 2007, Biomedical Optics: Principle and Imaging, 343
Cited by
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
PHOTOACOUSTIC TOMOGRAPHY: PRINCIPLES AND ADVANCES (Invited Review)
Xia, J., Yao, J., & Wang, L. H. V. (2014) · Progress In Electromagnetics Research · doi:10.2528/pier14032303 · Cited by 646
“Similar to Doppler ultrasound, photoacoustic Doppler flowmetry measures the axial flow speed on the basis of Doppler frequency shift [4, 121, 122].”
Self-citationYao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
“Photoacoustic Doppler flowmetry measures the axial flow speed on the basis of Doppler frequency shift, by using either intensity-modulated continuous-wave (CW) excitation [148, 149] or tone-burst excitation [150].”
MethodSelf-citationProspects of photoacoustic tomography
Wang, L. V. (2008) · Medical Physics · doi:10.1118/1.3013698 · Cited by 561
Self-citationPhotoacoustic imaging and characterization of the microvasculature
Hu, S., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3281673 · Cited by 427
“speed greater than 1 mm /s in turbid media because of the poor SNR of the intensity-modulated photoacoustic mechanism.(98,99) To measure in vivo blood flow at a higher speed, a PADF system with higher SNR is required.”
BackgroundSelf-citationSensitivity of photoacoustic microscopy
Yao, J., & Wang, L. V. (2014) · Photoacoustics · doi:10.1016/j.pacs.2014.04.002 · Cited by 418
“[15,21–24].”
Self-citationPhotoacoustic Microscopy and Computed Tomography: From Bench to Bedside
Wang, L. V., & Gao, L. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104553 · Cited by 246
“Analogous to the ultrasonic Doppler effect, the PA Doppler (PAD) effect was observed and utilized in axial speed measurement (87; 88).”
MethodSelf-citationIn vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth
Yao, J., Maslov, K. I., Shi, Y., Taber, L. A., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.001419 · Cited by 200
“Recently there has been a growing interest in measuring flow using photoacoustics [2-4].”
BackgroundSelf-citation‘Go with the flow ’: A review of methods and advancements in blood flow imaging
Daly, S. M., & Leahy, M. J. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201200071 · Cited by 115
Neurovascular photoacoustic tomography
Hu, S., & Wang, L. V. (2010) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2010.00010 · Cited by 111
“Recently, blood flow measurement using Doppler photoacoustics has been actively studied (Brunker and Beard, 2010; Fang et al., 2007a,b; Fang and Wang, 2009; Yao and Wang, 2010).”
Ultrasound-guided photoacoustic imaging: current state and future development
Bouchard, R. R., Sahin, O., & Emelianov, S. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.2930 · Cited by 107
Liu, C., Liang, Y., & Wang, L. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100156 · Cited by 91
Self-citationReview of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
“In a second study they used a more realistic phantom where they included also scattering (m 0 s 1⁄4 0:4=cm, path length 3 cm) and increased the density of carbon particles from 15% to 40% (v/v) [53].”
MethodEvans blue dye-enhanced capillary-resolution photoacoustic microscopy in vivo
Yao, J., Maslov, K., Hu, S., & Wang, L. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3251044 · Cited by 81
“11,12 Since the amplitude of the PA signal is proportional to the absorbed optical energy density (cid:1) i.e., specific optical absorption (cid:2) , the PA technique has the advantage of directly measuring the absorption spectra in vivo , allowing better tissue identification and providing…”
MethodSelf-citationMultiscale Functional and Molecular Photoacoustic Tomography
Yao, J., Xia, J., & Wang, L. V. (2015) · Ultrasonic Imaging · doi:10.1177/0161734615584312 · Cited by 82
Self-citationTransverse flow imaging based on photoacoustic Doppler bandwidth broadening
Yao, J., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3339953 · Cited by 75
“Previously, PA Doppler PAD shift was observed from flowing particles illuminated by an intensity-modulated continuous-wave CW laser beam.(5,6) This physical phenomenon provides a basis for PAD flowmetry in optically scattering media.”
BackgroundSelf-citationYang, Y., Wang, S., Tao, C., Wang, X., & Liu, X. (2012) · Applied Physics Letters · doi:10.1063/1.4736994 · Cited by 70
Opportunities for Photoacoustic-Guided Drug Delivery
Xia, J., Kim, C., & Lovell, J. F. (2015) · Current Drug Targets · doi:10.2174/1389450116666150707100328 · Cited by 73
“The speed of blood flow can be measured with a variety of methods, including Doppler frequency shift [45, 46], autocorrelation [47], and cross-correlation [48].”
Advanced photoacoustic and thermoacoustic sensing and imaging beyond pulsed absorption contrast
Gao, F., Feng, X., & Zheng, Y. (2016) · Journal of Optics · doi:10.1088/2040-8978/18/7/074006 · Cited by 71
Functional photoacoustic microscopy of hemodynamics: a review
Liu, C., & Wang, L. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00220-4 · Cited by 72
Self-citationZhao, Y., Yang, S., Chen, C., & Xing, D. (2014) · Optics Letters · doi:10.1364/ol.39.002565 · Cited by 60
Ultra-fast photoacoustic flow cytometry with a 05 MHz pulse repetition rate nanosecond laser
Nedosekin, D. A., Sarimollaoglu, M., Shashkov, E. V., Galanzha, E. I., & Zharov, V. P. (2010) · Optics Express · doi:10.1364/oe.18.008605 · Cited by 57
Photoacoustic Doppler Measurement of Flow Using Tone Burst Excitation
Sheinfeld, A., Gilead, S., & Eyal, A. (2010) · Optics Express · doi:10.1364/oe.18.004212 · Cited by 41
M-mode photoacoustic particle flow imaging
Fang, H., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.34.000671 · Cited by 39
Self-citationSimultaneous spatial and spectral mapping of flow using photoacoustic Doppler measurement
Sheinfeld, A., Gilead, S., & Eyal, A. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3509113 · Cited by 27
“Journal of Biomedical Optics 15(6), 066010 (November/December 2010)”
BackgroundThree-dimensional Optical-resolution Photoacoustic Microscopy
Hu, S., Maslov, K., & Wang, L. V. (2011) · Journal of Visualized Experiments · doi:10.3791/2729 · Cited by 28
“, axial flow velocity) [21, 22].”
Self-citationPulsed photoacoustic Doppler flowmetry using a cross correlation method
Brunker, J., & Beard, P. C. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.841760 · Cited by 25
“Subsequently, photoacoustic measurements of flow in a tissue mimicking phantom were obtained by recovering Doppler frequency shifts using CW excitation [6] [7].”
MethodRobin, J., Özbek, A., Reiss, M., Deán‐Ben, X. L., & Razansky, D. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3125398 · Cited by 30
“The contrast and resolution however diminish when imaging deeper into the brain, whilst reliable blood flow velocity in vivo mapping has not yet been possible with OA modalities [10]–[12].”
BackgroundMicro-Doppler Photoacoustic Effect and Sensing by Ultrasound Radar
Gao, F., Feng, X., & Zheng, Y. (2015) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2015.2504512 · Cited by 23
Jin, D., Yang, F., Chen, Z., Yang, S., & Xing, D. (2017) · Applied Physics Letters · doi:10.1063/1.5001272 · Cited by 23
All-optical photoacoustic Doppler transverse blood flow imaging
Qiao, W., Chen, Z., Zhou, W., & Xing, D. (2018) · Optics Letters · doi:10.1364/ol.43.002442 · Cited by 20
Limited-view photoacoustic tomography utilizing backscatterers as virtual transducers
Wu, D., Wang, X., Tao, C., & Liu, X. (2011) · Applied Physics Letters · doi:10.1063/1.3669512 · Cited by 20
In vivo optically encoded photoacoustic flowgraphy
Zhang, R., Wang, L., Yao, J., Yeh, C., & Wang, L. V. (2014) · Optics Letters · doi:10.1364/ol.39.003814 · Cited by 19
Self-citationZhao, Y., Chen, C., Liu, H., Yang, S., & Xing, D. (2016) · Applied Physics Letters · doi:10.1063/1.4968188 · Cited by 19
Zhang, R., Yao, J., Maslov, K. I., & Wang, L. V. (2013) · Applied Physics Letters · doi:10.1063/1.4819735 · Cited by 17
Self-citationPulsed photoacoustic flow imaging with a handheld system
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.2.026004 · Cited by 16
“used the Doppler shift of CW-modulated photoacoustics to extract velocity information from particle flow.(11,10) In a similar approach, Sheinfeld et al.”
MethodPulsed photoacoustic Doppler flow measurements in blood-mimicking phantoms
Brunker, J., & Beard, P. C. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.874469 · Cited by 12
“The flowmetry is therefore performed in acoustic-resolution mode, which enables greater measuring depths than are possible with optical-resolution Doppler flowmetry [6-9].”
MethodIn vivo label-free microangiography by laser speckle imaging with intensity fluctuation modulation
Wang, M., Zeng, Y., Liang, X., Feng, G., Lu, X., Chen, J., Han, D., & Yang, G. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.12.126001 · Cited by 8
“A number of noninvasive imaging techniques have been developed.(4,5) Magnetic resonance imaging can achieve visualization of blood flow and is widely used in clinical diagnosis,(6) but it is limited in its temporal and spatial resolution.”
BackgroundTriplex radiometric, photoacoustic, and ultrasonic imaging based on single-pulse excitation
Zhao, Y., Wang, S., Merrill, J. A., Arellano, J. D., Trevisi, L. M., Li, Y., Xiang, L., Qu, J., & Liu, L. (2020) · Optics Letters · doi:10.1364/ol.387501 · Cited by 6
Biophotonics for blood analysis
Daly, S. M. (2015) · Elsevier eBooks · doi:10.1016/b978-0-85709-662-3.00009-9 · Cited by 6
Photoacoustic tomography of micro-blood vessels in tissue mimicking phantom
Lü, T., & Zang, H. (2010) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2010.5639232 · Cited by 5
Tong, Y., Zhao, H., Fang, H., Zhao, Y., & Yuan, X. (2016) · AIP Advances · doi:10.1063/1.4942097 · Cited by 4
Self-citationYao, J., Maslov, K., & Wang, L. V. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.840676 · Cited by 4
“( ) 1/2 2 2 2 _ _ 1 2 2 f f m f m m v v v v + − ⎡ ⎤ = + − ⎢ ⎥ ⎣ ⎦ , (2)”
Self-citationDual-Wavelength Continuous Wave Photoacoustic Doppler Flow Measurement
Zhao, H., Liu, Y., Farooq, T., & Fang, H. (2021) · Photonic Sensors · doi:10.1007/s13320-021-0633-6 · Cited by 4
Self-citationThin photothermal endoscope for biomedical applications
Kaiplavil, S. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.9.097008 · Cited by 4
Recent progress in blood flow sensing
Chen, R. Y., Liang, J., Li, M., & Meng, E. F. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116457 · Cited by 3
M -mode photoacoustic flow imaging
Fang, H., Maslov, K., & Wang, L. V. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.810159 · Cited by 3
“z T B y t P y t P z C z z ⋅ − × >= ⊗ =< τ τ , (5) where B does not depend on τ and y.”
Self-citationPhotoacoustic imaging instrumentation for life sciences
Thakur, S. N., Singh, V., & Rai, P. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-91732-2.00021-5 · Cited by 2
Luo, Y., & Wang, L. V. (2025) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-025-01092-4 · Cited by 5
“PAT enables non-invasive blood flow imaging through various mechanisms [42], such as doppler shift [43], density tracking [44], transit time [45], and amplitude encoding [46].”
Self-citationDevelopment of real-time photoacoustic microscopy
Wang, L., Maslov, K., Yao, J., Li, L., & Wang, L. V. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.875415 · Cited by 2
“Although Doppler [17] and M-mode [18] methods have been utilized for photoacoustic flow measurements, both methods only measure flow velocity projected onto one axis: either along or perpendicular to the ultrasound axis.”
MethodSelf-citationMultiwavelength Photoacoustic Doppler Flowmetry of Living Microalgae Cells
Farooq, T., Wu, X., Yan, S., & Fang, H. (2024) · Biosensors · doi:10.3390/bios14080397 · Cited by 1
“On the other hand, the absorption spectrum in the flow state can be extracted from the Doppler-shifted power spectra [27,38,39].”
BackgroundSelf-citationPhotoacoustic flow measurement with ultra-high temporal resolution by coded excitation
Zhang, H. K., Shiina, T., Kondo, K., & Yamakawa, M. (2013) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2013.0473 · Cited by 1
“Capillaries, which have low blood flow rates and micrometer-scale diameters, can be captured by photoacoustic microscopy [2], [3].”
BackgroundFarooq, T., Ali, F., & Fang, H. (2025) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2966/1/012018 · Cited by 1
Self-citationYao, J., Maslov, K., & Wang, L. V. (2010) · Biomedical Optics and 3-D Imaging · doi:10.1364/biomed.2010.bwe2 · Cited by 1
Self-citationIntegrated photoacoustic/ultrasound imaging : Applications and new techniques
van den Berg, P. J. (2016) · doi:10.3990/1.9789036542845 · Cited by 2
McElligott-Daly, S. (2013) · University of Limerick Institutional Repository (University of Limerick) · doi:10.34961/10103
Photoacoustic Tomography of Microcirculation
Hu, S., & Wang, L. V. (2012) · Wiley eBooks · doi:10.1002/9783527651238.ch11
Self-citationSheinfeld, A., Gilead, S., & Eyal, A. (2010) · IEEE Convention of Electrical and Electronics Engineers in Israel · doi:10.1109/eeei.2010.5662145
Photoacoustic Doppler flowmetry
Fang, H., & Wang, L. V. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.761947
“PHOTOACOUSTC DOPPLER FLOW MEASURING EXPERIMENTS Our experiment system is developed from the previously home-built continuous-wave photoacoustic microscope and has been detailed in the recently publications.(9,10) Here, we will briefly describe the system using the function block diagram plotted in Fig.”
BackgroundMethodSelf-citationPhotoacoustic Doppler flowmetry of whole blood by pulsed laser
Lu, T., Wang, W., & Xu, H. (2012) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2012.6512907
“The feasibility of using photoacoustic doppler(PAD) effects in flowmetry had been demonstrated in previous research[2,3].”
MethodM-mode photoacoustic tomography for flowing target
Ma, S., & Yang, S. (2009) · doi:10.1109/cleopr.2009.5292639
Multi-wave EM-Acoustic Methods
Gao, F. (2017) · Springer theses · doi:10.1007/978-981-10-3716-0_2
Current Updates on Photoacoustic-Based Techniques for Breast Cancer Diagnosis
Biswas, P., Sudha, M., Agarwal, K., Bhatt, M., Sridhar, B., & Desai, B. M. A. (2025) · Lecture notes in nanoscale science and technology · doi:10.1007/978-3-031-94551-9_16
Joseph, F. K., Veysset, D. G., Lee, H., Bouma, B. E., & van Soest, G. (2026) · Journal of Physics Photonics · doi:10.1088/2515-7647/ae889d
“Most flow imaging techniques work by tracking particle transit time in the imaging correlation volume, which can be either optically (OR-PAM) or acoustically bounded (AR-PAM, tomography) [161– 164].”
Metadata
- Authors
- Fang, H., Maslov, K., & Wang, L. V.
- Affiliations
- Washington University in St. Louis (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2007-12-24
- Volume
- 91
- Issue
- 26
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2031415302
- Cited by
- 64
- References
- 16
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 5 · 2015: 5 · 2014: 6 · 2013: 6 · 2012: 4
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Update notices
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Keywords
- blood flow measurement, light scattering, blood-mimicking fluid, microcirculation, light-absorbing particles, flow velocity sensing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.