The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Photoacoustic imaging and characterization of the microvasculature
Open accessAbstract
Photoacoustic (optoacoustic) tomography, combining optical absorption contrast and highly scalable spatial resolution (from micrometer optical resolution to millimeter acoustic resolution), has broken through the fundamental penetration limit of optical ballistic imaging modalities-including confocal microscopy, two-photon microscopy, and optical coherence tomography-and has achieved high spatial resolution at depths down to the diffusive regime. Optical absorption contrast is highly desirable for microvascular imaging and characterization because of the presence of endogenous strongly light-absorbing hemoglobin. We focus on the current state of microvascular imaging and characterization based on photoacoustics. We first review the three major embodiments of photoacoustic tomography: microscopy, computed tomography, and endoscopy. We then discuss the methods used to characterize important functional parameters, such as total hemoglobin concentration, hemoglobin oxygen saturation, and blood flow. Next, we highlight a few representative applications in microvascular-related physiological and pathophysiological research, including hemodynamic monitoring, chronic imaging, tumor-vascular interaction, and neurovascular coupling. Finally, several potential technical advances toward clinical applications are suggested, and a few technical challenges in contrast enhancement and fluence compensation are summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationWater-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Self-citationMultiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Self-citationBiomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Self-citationMalonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,097
On the production and reproduction of sound by light
Bell, A. G. (1880) · American Journal of Science · doi:10.2475/ajs.s3-20.118.305 · Cited by 1,082
Imaging of angiogenesis: from microscope to clinic
McDonald, D. M., & Choyke, P. L. (2003) · Nature Medicine · doi:10.1038/nm0603-713 · Cited by 1,016
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Cited by
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
The unique role of nanoparticles in nanomedicine: imaging, drug delivery and therapy
Doane, T. L., & Burda, C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15260f · Cited by 1,098
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
Yao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Self-citationTwo-Photon Microscopy as a Tool to Study Blood Flow and Neurovascular Coupling in the Rodent Brain
Shih, A. Y., Driscoll, J. D., Drew, P. J., Nishimura, N., Schaffer, C. B., & Kleinfeld, D. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.196 · Cited by 458
Metadata
- Authors
- Hu, S., & Wang, L. V.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2010
- Volume
- 15
- Issue
- 1
- Pages
- 011101
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2109329707
- Cited by
- 427
- References
- 68
- FWCI
- 19.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoacoustic imaging and characterization of the microvasculature. https://app.cochat.ai/papers/10.1117/1.3281673
- The paper
- Hu, S., & Wang, L. V. (2010). Photoacoustic imaging and characterization of the microvasculature. Journal of Biomedical Optics. https://doi.org/10.1117/1.3281673
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.