The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Abstract
A modified version of the atomic force microscope is introduced that enables a precise measurement of the force between a tip and a sample over a tip-sample distance range of 30–150 Å. As an application, the force signal is used to maintain the tip-sample spacing constant, so that profiling can be achieved with a spatial resolution of 50 Å. A second scheme allows the simultaneous measurement of force and surface profile; this scheme has been used to obtain material-dependent information from surfaces of electronic materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Williams, C. C., & Wickramasinghe, H. K. (1986) · Applied Physics Letters · doi:10.1063/1.97288 · Cited by 413
Self-citation
Cited by
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Nonnenmacher, M., O’Boyle, M. P., & Wickramasinghe, H. K. (1991) · Applied Physics Letters · doi:10.1063/1.105227 · Cited by 2,343
Self-citationAdvances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Metadata
- Authors
- Martin, Y., Williams, C. C., & Wickramasinghe, H. K.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1987-05-15
- Volume
- 61
- Issue
- 10
- Pages
- 4723-4729
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2074398939
- Cited by
- 1,428
- References
- 3
- FWCI
- 20.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.