The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Abstract
A modified version of the atomic force microscope is introduced that enables a precise measurement of the force between a tip and a sample over a tip-sample distance range of 30–150 Å. As an application, the force signal is used to maintain the tip-sample spacing constant, so that profiling can be achieved with a spatial resolution of 50 Å. A second scheme allows the simultaneous measurement of force and surface profile; this scheme has been used to obtain material-dependent information from surfaces of electronic materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Williams, C. C., & Wickramasinghe, H. K. (1986) · Applied Physics Letters · doi:10.1063/1.97288 · Cited by 413
Self-citation
Cited by
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Nonnenmacher, M., O’Boyle, M. P., & Wickramasinghe, H. K. (1991) · Applied Physics Letters · doi:10.1063/1.105227 · Cited by 2,343
Self-citationAdvances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Direct measurement of colloidal forces using an atomic force microscope
Ducker, W. A., Senden, T. J., & Pashley, R. M. (1991) · Nature · doi:10.1038/353239a0 · Cited by 2,075
Force-distance curves by atomic force microscopy
Cappella, B., & Dietler, G. (1999) · Surface Science Reports · doi:10.1016/s0167-5729(99)00003-5 · Cited by 1,694
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
Magnetic imaging by ‘‘force microscopy’’ with 1000 Å resolution
Martin, Y., & Wickramasinghe, H. K. (1987) · Applied Physics Letters · doi:10.1063/1.97800 · Cited by 1,151
Self-citationScratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Nanostructured Oxides in Chemistry: Characterization and Properties
Fernández-García, M., Martínez-Arias, A., Hanson, J. C., & Rodriguez, J. A. (2004) · Chemical Reviews · doi:10.1021/cr030032f · Cited by 1,035
Phase imaging and stiffness in tapping-mode atomic force microscopy
Magonov, S. N., Elings, V., & Whangbo, M.-H. (1997) · Surface Science · doi:10.1016/s0039-6028(96)01591-9 · Cited by 1,020
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Scanning Tunneling Microscopy and Atomic Force Microscopy: Application to Biology and Technology
Hansma, P. K., Elings, V. B., Marti, O., & Bracker, C. E. (1988) · Science · doi:10.1126/science.3051380 · Cited by 716
Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems
Ekinci, K. L., Yang, Y. T., & Roukes, M. L. (2004) · Journal of Applied Physics · doi:10.1063/1.1642738 · Cited by 695
Scanning Interferometric Apertureless Microscopy: Optical Imaging at 10 Angstrom Resolution
Zenhausern, F., Martin, Y., & Wickramasinghe, H. K. (1995) · Science · doi:10.1126/science.269.5227.1083 · Cited by 692
Self-citationForces in atomic force microscopy in air and water
Weisenhorn, A. L., Hansma, P. K., Albrecht, T. R., & Quate, C. F. (1989) · Applied Physics Letters · doi:10.1063/1.101024 · Cited by 632
Improved fiber-optic interferometer for atomic force microscopy
Rugar, D., Mamin, H. J., & Guethner, P. (1989) · Applied Physics Letters · doi:10.1063/1.101987 · Cited by 629
Magnetic force microscopy: General principles and application to longitudinal recording media
Rugar, D., Mamin, H. J., Guethner, P., Lambert, S. E., Stern, J. E., McFadyen, I., & Yogi, T. (1990) · Journal of Applied Physics · doi:10.1063/1.346713 · Cited by 624
Jalili, N., & Laxminarayana, K. (2004) · Mechatronics · doi:10.1016/j.mechatronics.2004.04.005 · Cited by 610
Rugar, D., & Hansma, P. (1990) · Physics Today · doi:10.1063/1.881238 · Cited by 589
Attractive and repulsive tip-sample interaction regimes in tapping-mode atomic force microscopy
García, R., & San Paulo, A. (1999) · Physical Review B · doi:10.1103/physrevb.60.4961 · Cited by 570
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
Contact electrification using force microscopy
Terris, B. D., Stern, J. E., Rugar, D., & Mamin, H. J. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.2669 · Cited by 531
IMAGING AND CONTROL OF DOMAIN STRUCTURES IN FERROELECTRIC THIN FILMS VIA SCANNING FORCE MICROSCOPY
Gruverman, A., Auciello, O., & Tokumoto, H. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.101 · Cited by 495
Theories of scanning probe microscopes at the atomic scale
Hofer, W. A., Foster, A. S., & Shluger, A. L. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.1287 · Cited by 480
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Biological applications of atomic force microscopy
Lal, R., & John, S. A. (1994) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1994.266.1.c1 · Cited by 402
Fukuma, T., Kimura, M., Kobayashi, K., Matsushige, K., & Yamada, H. (2005) · Review of Scientific Instruments · doi:10.1063/1.1896938 · Cited by 387
Scanning Tunneling Microscopy and Atomic Force Microscopy in Organic Chemistry
Frommer, J. (1992) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199212981 · Cited by 383
Single molecule force spectroscopy in biology using the atomic force microscope
Zlatanova, J., Lindsay, S. M., & Leuba, S. H. (2000) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(00)00014-6 · Cited by 375
True atomic resolution in liquid by frequency-modulation atomic force microscopy
Fukuma, T., Kobayashi, K., Matsushige, K., & Yamada, H. (2005) · Applied Physics Letters · doi:10.1063/1.1999856 · Cited by 375
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
Bar, G., Thomann, Y., Brandsch, R., Cantow, H.-J., & Whangbo, M.-H. (1997) · Langmuir · doi:10.1021/la970091m · Cited by 324
Bian, K., Gerber, C., Heinrich, A. J., Müller, D. J., Scheuring, S., & Jiang, Y. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00033-2 · Cited by 314
Tamayo, J., & Garcı́a, R. (1997) · Applied Physics Letters · doi:10.1063/1.120039 · Cited by 292
San Paulo, A., & García, R. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76712-9 · Cited by 286
Noninductive detection of single-proton magnetic resonance
Sidles, J. A. (1991) · Applied Physics Letters · doi:10.1063/1.104757 · Cited by 267
Nonlinear Dependence of the Contact Angle of Nanodroplets on Contact Line Curvature
Checco, A., Guenoun, P., & Daillant, J. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.186101 · Cited by 267
Regulation of a microcantilever response by force feedback
Mertz, J., Marti, O., & Mlynek, J. (1993) · Applied Physics Letters · doi:10.1063/1.109413 · Cited by 265
Atomic scale friction between the muscovite mica cleavage plane and a tungsten tip
Erlandsson, R., Hadziioannou, G., Mate, C. M., McClelland, G. M., & Chiang, S. (1988) · The Journal of Chemical Physics · doi:10.1063/1.455608 · Cited by 263
Techniques for measuring surface forces
Claesson, P. M., Ederth, T., Bergeron, V., & Rutland, M. W. (1996) · Advances in Colloid and Interface Science · doi:10.1016/0001-8686(96)00302-8 · Cited by 260
Chemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Preparation of DNA and nucleoprotein samples for AFM imaging
Lyubchenko, Y. L. (2011) · Micron · doi:10.1016/j.micron.2010.08.011 · Cited by 93
Metadata
- Authors
- Martin, Y., Williams, C. C., & Wickramasinghe, H. K.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1987-05-15
- Volume
- 61
- Issue
- 10
- Pages
- 4723-4729
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2074398939
- Cited by
- 1,428
- References
- 3
- FWCI
- 20.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.