A microfabricated optically-pumped magnetic gradiometer
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Bloch Equations with Diffusion Terms
Torrey, H. C. (1956) · Physical Review · doi:10.1103/physrev.104.563 · Cited by 1,216
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
A robust scanning diamond sensor for nanoscale imaging with single nitrogen-vacancy centres
Maletinsky, P., Hong, S., Grinolds, M. S., Hausmann, B., Lukin, M. D., Walsworth, R. L., Loncar, M., & Yacoby, A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.50 · Cited by 726
Chip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481
Self-citationSubfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Self-citationSpin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Research works printed but not linked: 3
- D. Budker and D. F. J. Kimball, Optical Magnetometry (Cambridge University Press, 2013).
- J. Preusser, S. Knappe, J. Kitching, and V. Gerginov, in 2009 IEEE International Frequency Control Symposium Joint with the 22nd European Frequency and Time Forum (IEEE, 2009), pp. 1180-1182.
- S. J. Seltzer, Ph.D. thesis, Princeton University (2008).
Cited by
Items 101–181 of 181
Qin, J., Zhou, Y., & Wang, Y. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3137161 · Cited by 8
Du, P., Li, J., Yang, S., Wang, X.-T., Zhuo, Y., Wang, F., & Wang, R. (2019) · Chinese Physics B · doi:10.1088/1674-1056/28/4/040702 · Cited by 8
Collimated versatile atomic beam source with alkali dispensers
Wei, B., Crawford, A., Andeweg, Y., Zhuo, L., Li, C., & Raman, C. (2022) · Applied Physics Letters · doi:10.1063/5.0087155 · Cited by 7
Zheng, F., Li, C., Li, D., Xu, W., Ru, X., Cheng, H., Liu, Z., Na, S., Qin, L., Lyu, B., et al. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3435882 · Cited by 8
“Spin-exchange relaxation-free (SERF) magnetometers, a type of OPM, have shown unparalleled sensitivity [15], [16], [17].”
BackgroundHigh-Sensitivity, Microfabricated Quantum Magnetometers With an Intelligent Solar Heating System
Ma, Y., Chen, Y., Yu, M., Yanbin, W., Guo, J., Zhao, M., Yang, P., Lin, Q., & Zhao, L. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3519377 · Cited by 10
“The power required to run the quantum sensors for a well vacuum-encapsulated atomic vaporcellismainlygovernedbytheradiativeheatloss[16],[17].”
Modulation crosstalk effect analysis on single-beam SERF atomic magnetic gradiometer
Chen, T., Zheng, Z., Zhang, J., Chen, Z., Chen, W., Ou, Z., Yue, H., & Liu, Y. (2025) · Measurement · doi:10.1016/j.measurement.2025.117782 · Cited by 8
Spin-amplification SERF atomic magnetometer based on direct feedback
Ma, Y., Yuan, Z., Lin, S., Zhai, Y., & Tang, J. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00378-7 · Cited by 7
Kim, M. M., Lee, S., Yim, S. H., & Yoon, J.-H. (2023) · Journal of Applied Physics · doi:10.1063/5.0141434 · Cited by 7
Quantum magnetometry for space
Deans, C., Valenzuela, T., & Bason, M. G. (2023) · International Conference on Space Optics (ICSO) · doi:10.1117/12.2691360 · Cited by 6
“The maximum rejection of magnetic field noise is 1000 at 10Hz.(27)”
BackgroundEnhanced fully optically pumped magnetic resonance with optical sideband auxiliary pumping
Jiang, Z., Liu, X., Lin, P., Qu, J., & Liu, H. (2019) · Optics Letters · doi:10.1364/ol.45.000105 · Cited by 6
SERF-like magnetometry in room-temperature environment
Bao, G., Chen, J., Wang, R., Chen, L. Q., & Zhang, W. (2023) · Optics Express · doi:10.1364/oe.500875 · Cited by 6
Magnetic field sensing based on multi-order resonances of atomic spins
Yang, H., Wang, Q., Zhao, B., Li, L., Zhai, Y., Han, B., & Tang, F. (2021) · Optics Express · doi:10.1364/oe.443679 · Cited by 6
Optically Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_49 · Cited by 7
Self-citationQuantum locking of intrinsic spin squeezed state in Earth-field-range magnetometry
Yang, P., Bao, G., Chen, J., Du, W., Guo, J., & Zhang, W. (2025) · npj Quantum Information · doi:10.1038/s41534-025-00971-9 · Cited by 7
“Similar closed-loop schemes have been achieved in conventional optically pumped magnetometry by self-oscillating 64 or phase lock loop 65 which lock the frequency of driving fi eld to the Larmor frequency.”
Light-noise suppression method for the single-beam optically-pumped magnetometer arrays
Suo, Y., Song, X., Wu, Z., Yuan, Z., Jia, L., & Long, T. (2023) · Optics Express · doi:10.1364/oe.489172 · Cited by 5
Duan, Z., Long, T., Wu, Z., Jia, L., Qi, S., Song, X., & Han, B. (2024) · Measurement · doi:10.1016/j.measurement.2024.116376 · Cited by 6
Atomic Josephson parametric amplifier
Singh, V. P., Amico, L., & Mathey, L. (2026) · Physical Review Research · doi:10.1103/7s1n-ddp9 · Cited by 5
Liu, J., Jiang, L., Xu, J., Chen, Y., Li, X., & Wang, Z. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3614826 · Cited by 7
“OPMs operating in the spin-exchange relaxation-free (SERF) regime achieve sensitivity comparable to superconducting quantum interference devices (SQUIDs) and have been widely applied in near-zero-field conditions [11], [12], [13].”
Sargsyan, A. D., Vartanyan, T. A., & Sarkisyan, D. G. (2020) · Optics and Spectroscopy · doi:10.1134/s0030400x20050112 · Cited by 5
Ma, Y., Qiao, Z., Chen, Y., Luo, G., Yu, M., Wang, Y., Lu, D., Zhao, L., Yang, P., Lin, Q., et al. (2023) · Optics Express · doi:10.1364/oe.483108 · Cited by 6
Compact Mz atomic magnetometer with a thick silicon core MEMS vapor cell
Li, Q., Qin, J., Jiang, Y., Jia, S., & Jiang, Z. (2024) · Optics Communications · doi:10.1016/j.optcom.2024.130866 · Cited by 5
Microfabricated optically-pumped magnetometers for imaging applications
Knappe, S. A., Hughes, J. V., & Alem, O. (2023) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.2657353 · Cited by 6
“The operation under negative feedback [60, 61], where the magnetic resonance signal is used to feed back onto a set of compensation coils to keep the sensors in a zerofield environment can drastically improve scale factor stability, linearity, and bandwidth [62].”
BackgroundSelf-citationSERF Comagnetometer Based on Self-Differential Mode
Zhou, S., Wei, K., Huang, X., Rui, Y., Heng, X., Zheng, J., & Quan, W. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3568999 · Cited by 9
“Heilman et al. [26], Sheng et al. [27], and Wu et al. [28] designed a dual-cell gradiometer to suppress the common-mode noise by di ff erential.”
A compact unshielded optically pumped magnetic gradiometer
Ye, H., Xu, C., Hu, M., & Dong, H. (2025) · Review of Scientific Instruments · doi:10.1063/5.0233804 · Cited by 4
“In the voltage differential mode, the voltage outputs of two separate atomic magnetometers with appreciate baseline are subtracted to obtain the magnetic field gradient information [6-12].”
Gu, W., Li, D., & Gao, J. (2023) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2023.110010 · Cited by 4
Advances in laser heating of alkali vapor cells in magnetometers: a review
Wang, K., Zhou, B., Tang, J., Zhang, S., & Wang, Y. (2020) · Applied Optics and Photonics China (AOPC) · doi:10.1117/12.2574588 · Cited by 5
OPM Gradiometer for Magnetorelaxometry
Prospero, A. G., Miranda, J. R. D. A., & Baffa, O. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_12 · Cited by 4
Quantum Sensing of Magnetic Fields Using Global Optimization Algorithms
Xiao, W., Ding, Y., Wu, T., Peng, X., & Guo, H. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024042 · Cited by 4
Frequency-dependent gradient error suppression method for optically pumped magnetic gradiometers
Lin, S., Yuan, Z., Ma, Y., Zhai, Y., & Tang, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.118138 · Cited by 3
Dual-resonance single-beam triaxial spin-exchange relaxation-free magnetometer
Zhang, G., Yu, W., Gao, Y., Wang, F., Zhang, Q., & Lin, Q. (2025) · Optics Express · doi:10.1364/oe.568707 · Cited by 3
Shipborne Experimental Demonstration of an Atomic Spin Comagnetometer for Dual-Axis Rotation Sensing
Gao, H., Cai, Z. Y., Fan, W., Zhang, K., Li, X., & Quan, W. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3655955 · Cited by 3
“…to the spin-polarization direction, one may adopt a scheme analogous to a spatial di ff erential gradiometer in atomic magnetometry: two vapor cells measure the local fields at separated positions, and signal di ff erencing suppresses common-mode magnetic noise and improves sensitivity [20], [21].”
Microfabricated Optically Pumped Gradiometer with Uniform Buffer Gases
Parrish, A. R., Noor, R. M., & Shkel, A. M. (2021) · IEEE International Symposium on Inertial Sensors and Systems (INERTIAL) · doi:10.1109/inertial51137.2021.9430474 · Cited by 3
“This reduces the common mode noise rejection in the gradiometer [3].”
BackgroundOptically Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_49-1 · Cited by 3
Self-citationAdult Magnetocardiography: Principles and Clinical Practice
Erasala, V., Senagore, A. J., Shrivastava, P., Malhotra, R., Setegn, E., & Sokolowski, R. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_14 · Cited by 3
Quantum States Imaging of Magnetic Field Contours Based on Autler-Townes Effect in Ytterbium Atoms
Narong, T. N., Li, H., Tong, J., Dueñas, M., & Hollberg, L. W. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.193201 · Cited by 3
Schneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_78-1 · Cited by 4
Jiang, M., Wang, J., Zhai, H., Chen, C., Zhang, Q., Wu, D., Zhang, B., Zeng, Z., Lin, J., Wang, Y., et al. (2024) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad43ce · Cited by 3
Monolithically Integrated 3D Atomic Chip for Quantum Optical Magnetometry
Wang, Z., Wu, J., Sun, G., & Shang, J. (2023) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2023.3337513 · Cited by 2
“Additionally, temperature variations will induce changes of in-cell atomic density and buffer gas has proposed diverse temperature control methods, which are mainly divided into air flow [16], [17], light [8], [18] and conductive electrical heating [19], [20], [21].”
BackgroundInfluence of laser heating temperature characteristics on SERF atomic magnetometer
Zheng, Z., Chen, F., Zhou, Z., Chen, W., Ou, Z., Yue, H., & Liu, Y. (2025) · Optics Express · doi:10.1364/oe.573866 · Cited by 2
Light shift cross-sectional distribution measurement and suppression in SERF atomic magnetometers
Wang, Y., Yuan, Z., Lin, S., Xu, Y., Tang, J., Zhai, Y., & Liu, Y. (2025) · Measurement · doi:10.1016/j.measurement.2025.119325 · Cited by 3
Fenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2026) · Sensors · doi:10.3390/s26041369 · Cited by 6
“Although experimental evidence has been reported that SERF-OPM gradiometers could be improved to operate even in unshielded environments [69], efforts have focused on improving the sensitivity achievable with scalar OPMs arranged in gradiometric configurations.”
Matsubara, T., Sohrabpour, A., Ahlfors, S. P., Jas, M., Samuelsson, J. G., Sundaram, P., & Stufflebeam, S. M. (2026) · NeuroImage · doi:10.1016/j.neuroimage.2026.121930 · Cited by 2
“OPMs can be positioned directly on the scalp, eliminating the constrains of traditional cryogenic SQUID helmets and reducing the source-to-sensor distance (Alem et al., 2023; Bagic et al., 2023; Boto et al., 2018; Jas et al., 2021; Pedersen et al., 2022; Sheng et al., 2017).”
Баранцев, К. А., Litvinov, A. N., Pazgalev, A. S., & Vershovskii, A. K. (2022) · Journal of Experimental and Theoretical Physics · doi:10.1134/s1063776122050089 · Cited by 2
Duan, L., Ma, L., Hu, Z., Cai, Z. Y., & Gao, H. (2024) · Optics Express · doi:10.1364/oe.527556 · Cited by 2
Yi, G., Li, Y., Li, Y., Liu, X., Dong, X., & Gao, X. (2025) · Sensors · doi:10.3390/s25010234 · Cited by 3
Yin, K., Wang, J., Liu, Z., Yan, Y., Shang, H., & Zhou, B. (2020) · Applied Optics and Photonics China (AOPC): Optoelectronics and Nanophotonics · doi:10.1117/12.2579712 · Cited by 2
Dynamic range and linearity improvement for zero-field single-beam atomic magnetometer
Yin, K., Lu, J., Lu, F., Li, B., Zhou, B., & Ye, M. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac6010 · Cited by 2
Fiber-Coupled OPM in Purely Coil-Shielded Environment
Wu, T., Peng, X., Chen, J., & Guo, H. M. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_9 · Cited by 2
Virtual Gradiometer-Based Noise Reduction Method for Wearable Magnetoencephalography
Xu, J.-Y., Chen, C.-Q., Zhang, X., Fu, F.-Y., Yang, X., Hu, T., & Chang, Y. (2022) · International Conference on Computer Science, Electronic Information Engineering and Intelligent Control Technology (CEI) · doi:10.1109/cei57409.2022.9950167 · Cited by 2
“designed a gradiometer consisting of two micro fabricated vapor cells with a baseline of 20 mm [13].”
MethodNonzero-Order Resonances in Single-Beam Spin-Exchange Relaxation-Free Magnetometers
Wang, K., Zhang, K., Xu, N., Yan, Y., Li, X., & Zhou, B. (2023) · Photonics · doi:10.3390/photonics10040458 · Cited by 2
Single-Beam, Dual-Channel Self-Oscillating Optically Pumped Magnetometer
Wang, X., Fu, Y., Yu, H., Zhang, X., Wang, H., & Zheng, W. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3637032 · Cited by 1
“Compared with the typical magnetic gradiometer structure that employs at least two laser beams to illuminate two separate cells [14], [15], [16], [17], this single-beam configuration enables a more compact sensor probe.”
Faraday–Ramsey Rotation in Ultrathin Alkali Vapor Cells as an Analogy to Atomic‐Beam Systems
Dikopoltsev, M., Talker, E., Barash, Y., Mazurski, N., & Levy, U. (2026) · Laser & Photonics Review · doi:10.1002/lpor.202502129 · Cited by 1
“The thin-cell geometry enables 2D, millimeter-scale magnetic gradiometry, which is usually achieved with separate cells [ 24 ].”
A Single-Cell Optically Pumped Intrinsic Gradiometer
Zilinski, N., Parameswaran, A. M., Gray, B. L., & Cheung, T. P. L. (2026) · Sensors · doi:10.3390/s26051678 · Cited by 1
“Magnetic gradiometers can be used to mitigate noise by attenuating common-mode fields; however, constructing well-matched sensors with separate cells and electronics can be complex, while also increasing sensor noise levels [23–25].”
Microwave-optical double-resonance vector magnetometry with warm Rb atoms
Babaei, B., Smith, B. D., Tretiakov, A., Narayanan, A., & LeBlanc, L. J. (2026) · Applied Physics Letters · doi:10.1063/5.0323832 · Cited by 1
Spin-Feedback-Enhanced Atomic Magnetic Gradiometer
Ma, Y., Lin, S., Yuan, Z., Zhai, Y., & Tang, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3704257 · Cited by 1
“Various approaches have been explored to improve CMRR [29], [30], [31], [32], such as implementing proportional-integral-derivative closed-loop control [33], [34] and adjusting operating parameters to optimize phase consistency at specific frequencies [35].”
Magnetic Field Imaging with Microfabricated Optically-Pumped Magnetometer Arrays
Nardelli, N. V., Krzyzewski, S., Korenko, B., Romanov, G., Hughes, J. V., Alem, O., & Knappem, S. (2019) · Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC) · doi:10.1109/cleoe-eqec.2019.8872678 · Cited by 1
Self-citationDeveloping Gradiometer to Reduce the Low Frequency Noise of Magnetic Sensor with Amorphous Wire
He, D. (2021) · Journal of Electrical and Electronic Engineering · doi:10.11648/j.jeee.20210902.11 · Cited by 1
“Different from normal electrical gradiometer [20-22] with independent driving circuits for two sensors, the two sensors of this gradiometer shared the DC bias current and the AC bias current.”
BackgroundSupine OPM-MEG in Multilayer Cylindrical Shield
Sheng, J., Li, D., Wan, S., Qin, J., & Gao, J. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_4 · Cited by 1
All-Optical Faraday-Rotation-Modulated SERF Magnetometer With Enhanced Sensitivity
Yan, Y., Zhou, C., Liu, Z., Wu, Y., Ding, X., Zhou, Y., & Lu, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3581661 · Cited by 1
YANG, 杨. S.-R., WANG, 王. Q.-W., FU, 伏. J.-Q., & KONG, 孔. J. (2024) · Acta Sinica Quantum Optica · doi:10.3788/jqo20243003.0202 · Cited by 1
A single beam Cs-Ne SERF magnetometer with differential laser power noise suppression methodPreprint
Chen, Y., Ma, Y., Yu, M., Zhang, N., Zhao, L., Han, X., & Jiang, Z. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2101.01811 · Cited by 2
“The theory and optimization method of the modulation could be found in several references [16,17].”
MethodCorrection Method of The Cross-type Tensor Based on DA-LM
Li, C., & Zhang, S. (2023) · Academic Journal of Science and Technology · doi:10.54097/ajst.v5i1.5636 · Cited by 1
Coget, G. (2018) · theses.fr (ABES) · doi:10.70675/82d4fa79z8606z471ez8106zb280b9e7474d · Cited by 1
A Magnetic Field Gradiometer based on the Laser Helium Optically Pumped Magnetic Field Sensors
(2020) · International Journal of Circuits Systems and Signal Processing · doi:10.46300/9106.2020.14.44
Chip-Scale SERF Atomic Magnetometer Realized by Virtual Lock-in Amplifier
Sun, G., Shang, J., Wu, J., Zhang, J., Li, W., & Zhang, J. (2022) · International Conference on Electronic Packaging Technology (ICEPT) · doi:10.1109/icept56209.2022.9872617
“2022 23rd International Conference on Electronic Packaging Technology (ICEPT) During the measurement, vapor cell and heating module are placed in the magnetic shielding cylinder, and the cell is heated to 150°C to increase atomic density[12].”
Optically Pumped Magnetometers Compatible with Large Transient Magnetic Fields
Nardelli, N. V., Krzyzewski, S., & Knappe, S. A. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_2
Self-citationHeating opaque material sheets by a blue laser
Sibsiri, K., Kijamnajsuk, P., Sutthiopad, M., & Luengviriya, C. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2793/1/012006
Miniature Quantum Gradiometer Using 3D Interconnected Atomic Vapor Cells
Zhang, J., & Shang, J. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917793
“The MEMS atomic vapor cell is the core component of the MQG [5], [6].”
Response of comagnetometers to exotic spin-dependent couplings
Zhao, Y., Peng, X., Wu, T., & Guo, H. (2025) · Physical review. D/Physical review. D. · doi:10.1103/824f-v3w5
Chip-scale atomic birefringent diffractive-optical-elements
Nefesh, O., Krelman, H., Levi, K., & Stern, L. (2025) · APL Photonics · doi:10.1063/5.0284054
Towards naturalistic scanning environments for wearable magnetoencephalography
Rea, M. (2023) · Nottingham ePrints (University of Nottingham)
Analysis and Application of Multi-Pass Reflection Schemes in a K–Rb– 21 Ne atomic comagnetometer
Ge, X., Pang, H., Ma, L., & Fan, W. (2025) · International Symposium on Sensor Technology and Control (ISSTC) · doi:10.1109/isstc67929.2025.11308490
“…progress has been achieved in areas such as symmetry tests (including CPT and Lorentz invariance) [1]–[3], electric dipole moment (EDM) experiments [4], [5], searches for anomalous spin-dependent interactions [6], [7], as well as high-sensitivity magnetic field and inertial measurements [8]–[10].”
Probe-assisted depopulation pumping in low-pressure alkali-metal vapor cells for magnetometry
Limes, M. E., Smoot, J., Perez, J., Freeman, J., Amano-Dolan, C., Peters, D., & Lee, W. (2026) · Physical Review A · doi:10.1103/pbrt-m6q3
“Here, calibration is provided by the gyromagnetic ratio γ = ω/B [12–15], rather than the voltage/field measurements of SERF and RF [16] sensors that require frequent calibration.”
Yin, Y., Xu, A., Liu, B., & Deng, L. (2026) · Optics Letters · doi:10.1364/ol.579150
Gal, G. L. (2022) · theses.fr (ABES) · doi:10.70675/087f6445zef80z4bbfz837ez1374c2977052
Identification and Analysis of Thermal–Magnetic Coupling Noise in SERF Comagnetometer
Huang, X., Heng, X., Gong, D., Zhu, H., Gong, D., Liu, Y., Quan, W., & Wei, K. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3682821 · Cited by 1
“In high-atomic number density sensors, common heating methods include hot air flow [2], [15], nonmagnetic electrical heating [16], [17], and laser heating [18], [19].”
Jiang, L., Yang, J., Chen, J., Zhang, C., Peng, Z., Bei, S., & Liu, J. (2026) · Measurement · doi:10.1016/j.measurement.2026.122636
Zhu, Y., Sun, J., Huang, K., & Chai, Z. (2026) · Review of Scientific Instruments · doi:10.1063/5.0305055
Intrinsic Vectorial Gradiometry via Quantum Control of a Spin-based SensorPreprint
Oliván, J. G., Acedo, P., Whaites, O. T., & Casanova, J. (2026) · Research Square · doi:10.21203/rs.3.rs-11204203/v1
Ultra-high-fidelity reactor pressure vessel monitoring using SERF magnetometer arrays
Mahomane, R. R., Pokaha, M. T., & Mathuthu, M. (2026) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2026.112853
Auditory evoked responses during ambulatory OP-MEG
Mellor, S., Tierney, T. M., Osborne, J., Spedden, M. E., Seymour, R. A., Alexander, N., Doyle, C., Bobela, D., O’Neill, G. C., Rudzka, K., et al. (2026) · Imaging Neuroscience · doi:10.1162/imag.a.1424
Metadata
- Authors
- Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2017-01-16
- Volume
- 110
- Issue
- 3
- Pages
- 031106-031106
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- PMC
- PMC5250637
- OpenAlex
- W2572181495
- Cited by
- 179
- References
- 27
- Citations by year
- 2026: 13 · 2025: 26 · 2024: 15 · 2023: 30 · 2022: 25 · 2021: 25 · 2020: 17 · 2019: 23 · 2018: 2 · 2017: 3
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Applied Physics Letters (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Institutes of Health (1R01EB019440,1R44NS090894,R01NS094604)
- National Institute of Standards and Technology (Embedded Standards/NIST on a Chip initiative (EBS14))
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- magnetic gradiometer, atomic magnetometer, microfabrication, spin-exchange relaxation-free, alkali metal vapors, optical pumping, chip-scale sensors, magnetic field gradient measurement, common-mode noise suppression, compensation coils, intensity inhomogeneity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.