A microfabricated optically-pumped magnetic gradiometer
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Bloch Equations with Diffusion Terms
Torrey, H. C. (1956) · Physical Review · doi:10.1103/physrev.104.563 · Cited by 1,216
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
A robust scanning diamond sensor for nanoscale imaging with single nitrogen-vacancy centres
Maletinsky, P., Hong, S., Grinolds, M. S., Hausmann, B., Lukin, M. D., Walsworth, R. L., Loncar, M., & Yacoby, A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.50 · Cited by 726
Chip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481
Self-citationSubfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Self-citationSpin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Research works printed but not linked: 3
- D. Budker and D. F. J. Kimball, Optical Magnetometry (Cambridge University Press, 2013).
- J. Preusser, S. Knappe, J. Kitching, and V. Gerginov, in 2009 IEEE International Frequency Control Symposium Joint with the 22nd European Frequency and Time Forum (IEEE, 2009), pp. 1180-1182.
- S. J. Seltzer, Ph.D. thesis, Princeton University (2008).
Cited by
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
“…C. Johnson, Schwindt and Weisend, 2010; Kim et al., 2014; Labyt et al., 2018; Osborne et al., 2018; Sander et al., 2012a; Shah and Wakai, 2013; J. Sheng et al., 2017b; Xia et al., 2006), somatosensory evoked responses (Borna et al., 2017a; Boto et al., 2016b; C. Johnson et al., 2010; Kamada et…”
BackgroundMethodUltrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers
Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba8792 · Cited by 222
Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system
Brookes, M. J., Boto, E., Rea, M., Shah, V., Osborne, J., Holmes, N., Hill, R. M., Leggett, J., Rhodes, N., & Bowtell, R. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118025 · Cited by 151
Precision Magnetometers for Aerospace Applications: A Review
Bennett, J. S., Vyhnalek, B. E., Greenall, H., Bridge, E. M., Gotardo, F., Forstner, S., Harris, G. I., Miranda, F. A., & Bowen, W. P. (2021) · Sensors · doi:10.3390/s21165568 · Cited by 161
Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136
“…have seen vast progress in miniaturisation of OPM sensors (Borna et al., 2017; Jiménez-Martínez and Knappe, 2017; Kamada et al., 2015; Osborne et al., 2018; Sheng et al., 2017) and this work has ultimately led to the recent (2018) commercialisation of a new generation of smaller and lighter OPMs.”
BackgroundInterference suppression techniques for OPM-based MEG: Opportunities and challenges
Seymour, R. A., Alexander, N., Mellor, S., O’Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118834 · Cited by 138
“As these devices are not superconducting, there is no option (as in SQUID systems) for a flux transformer to couple flux to a single sensor, but rather two or more active elements are required to create a gradiometer (Sheng et al., 2017).”
Precision magnetic field modelling and control for wearable magnetoencephalography
Rea, M., Holmes, N., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Woolger, D., Dawson, E., Shah, V., Osborne, J., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118401 · Cited by 118
“, 2012)) and sensor miniaturisation and commercialisation (Allred et al., 2002; Johnson et al., 2013; Kamada et al., 2015; Kominis et al., 2003; Mhaskar et al., 2012; Sander et al., 2012; Schwindt et al., 2007; Shah and Wakai, 2013; Sheng et al., 2017) means that robust, small, and lightweight OPMs can now be mounted…”
BackgroundTierney, T. M., Alexander, N., Mellor, S., Holmes, N., Seymour, R. A., O’Neill, G. C., Maguire, E. A., & Barnes, G. R. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118484 · Cited by 135
Tang, J., Zhai, Y., Li, C., Zhang, Y., Li, L., Zhao, B., Zhou, B., Han, B., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.425851 · Cited by 128
An integrated full-head OPM-MEG system based on 128 zero-field sensors
Alem, O., Hughes, K. J., Buard, I., Cheung, T., Maydew, T., Griesshammer, A., Holloway, K., Park, A., Lechuga, V., Coolidge, C., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1190310 · Cited by 114
“Finally, our sensor operate in a closed-loop feedback configuration in their sensitive axis (Lee et al., 2014; Sheng et al., 2017), where the demodulated photodiode signal is fed back to the sensor coils to continually keep the atoms on the zerocrossing of the resonance.”
MethodSelf-citationQuantum‐Based Magnetic Field Sensors for Biosensing
Bao, B., Hua, Y., Wang, R., & Li, D. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202200146 · Cited by 108
Potential of on‐scalp MEG: Robust detection of human visual gamma‐band responses
Iivanainen, J., Zetter, R., & Parkkonen, L. (2020) · Human Brain Mapping · doi:10.1002/hbm.24795 · Cited by 99
“Recent advances in the development of optically-pumped magnetometers (OPMs) (Budker & Romalis, 2007; Budker & Kimball, 2013) has enabled their use in MEG (e.g. Borna et al., 2017; Sheng et al., 2017; Boto et al., 2018; Iivanainen et al., 2019).”
Nardelli, N. V., Perry, A. R., Krzyzewski, S. P., & Knappe, S. A. (2020) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-020-00086-4 · Cited by 85
Self-citationReducing crosstalk in optically-pumped magnetometer arrays
Nardelli, N. V., Krzyzewski, S. P., & Knappe, S. A. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab4c06 · Cited by 80
“A detailed description of the sensor geometry can be found in Sheng et al (2017).”
MethodSelf-citationClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Magnetoencephalography with a Cs-based high-sensitivity compact atomic magnetometer
Sheng, J., Wan, S., Sun, Y., Dou, R., Guo, Y., Wei, K., He, K., Qin, J., & Gao, J.-H. (2017) · Review of Scientific Instruments · doi:10.1063/1.5001730 · Cited by 80
Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Sulai, I. A., DeLand, Z. J., Bulatowicz, M. D., Wahl, C. P., Wakai, R. T., & Walker, T. G. (2019) · Review of Scientific Instruments · doi:10.1063/1.5091007 · Cited by 79
Wang, J., Fan, W., Yin, K., Yan, Y., Zhou, B., & Song, X. (2020) · Physical Review A · doi:10.1103/physreva.101.053427 · Cited by 77
Femtotesla Direct Magnetic Gradiometer Using a Single Multipass Cell
Lucivero, V. G., Lee, W., Dural, N., & Romalis, M. V. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.014004 · Cited by 77
Optically Pumped Magnetometers for Magneto-Myography to Study the Innervation of the Hand
Broser, P. J., Knappe, S. A., Kajal, D. S., Noury, N., Alem, O., Shah, V., & Braun, C. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2871947 · Cited by 77
“The OPM system (QuSpin QZFM, [18]–[20]) was used to measure the magnetic field.”
Self-citationKrzyzewski, S., Perry, A. R., Gerginov, V. P., & Knappe, S. A. (2019) · Journal of Applied Physics · doi:10.1063/1.5098088 · Cited by 72
Self-citationRecent Progress of Biomimetic Tactile Sensing Technology Based on Magnetic Sensors
Man, J., Chen, G., & Chen, J. (2022) · Biosensors · doi:10.3390/bios12111054 · Cited by 70
“Although it can be miniaturized with the help of MEMS technology, it is often difficult to achieve both miniaturization and sensitivity [93,94].”
BackgroundEntanglement-Based dc Magnetometry with Separated Ions
Ruster, T., Kaufmann, H., Luda, M. A., Kaushal, V., Schmiegelow, C. T., Schmidt-Kaler, F., & Poschinger, U. G. (2017) · Physical Review X · doi:10.1103/physrevx.7.031050 · Cited by 69
He, K., Wan, S., Sheng, J., Liu, D., Wang, C., Li, D., Qin, L., Luo, S., Qin, J., & Gao, J. (2019) · Review of Scientific Instruments · doi:10.1063/1.5066250 · Cited by 71
Fourcault, W., Romain, R., Le Gal, G., Bertrand, F., Josselin, V., Le Prado, M., Labyt, E., & Palacios-Laloy, A. (2021) · Optics Express · doi:10.1364/oe.420031 · Cited by 65
Single-Beam Atomic Magnetometer Based on the Transverse Magnetic-Modulation or DC-Offset
Liu, G., Tang, J., Yin, Y., Wang, Y., Zhou, B., & Han, B. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2973201 · Cited by 64
“SERF magnetometers operate with a net spin polarization, and the spin undergoes Larmor precession in the external magnetic field [19], [20].”
BackgroundMagnetic Field Mapping and Correction for Moving OP-MEG
Mellor, S., Tierney, T. M., O'Neill, G. C., Alexander, N., Seymour, R. A., Holmes, N., Lopez, J. D., Hill, R. M., Boto, E., Rea, M., et al. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3100770 · Cited by 54
Spherical harmonic based noise rejection and neuronal sampling with multi-axis OPMs
Tierney, T. M., Mellor, S., O’Neill, G. C., Timms, R. C., & Barnes, G. R. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119338 · Cited by 62
Magnetic Measurement of Electrically Evoked Muscle Responses With Optically Pumped Magnetometers
Elzenheimer, E., Laufs, H., Schulte‐Mattler, W., & Schmidt, G. U. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2968148 · Cited by 60
“A detailed description of the fundamental sensor principle and the commercial system used here can be found in [9]–[12].”
Femtotesla Nearly-Quantum-Noise-Limited Pulsed Gradiometer at Earth-Scale Fields
Lucivero, V. G., Lee, W., Limes, M. E., Foley, E. L., Kornack, T. W., & Romalis, M. V. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.l021001 · Cited by 60
Prospects for magnetic field communications and location using quantum sensors
Gerginov, V. P., da Silva, F. C. S., & Howe, D. A. (2017) · Review of Scientific Instruments · doi:10.1063/1.5003821 · Cited by 54
Magnetic Gradiometer for the Detection of Zero- to Ultralow-Field Nuclear Magnetic Resonance
Jiang, M., Picazo‐Frutos, R., Wu, T., Blanchard, J. W., Peng, X., & Budker, D. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.024005 · Cited by 53
Magnetic field modeling with surface currents. Part II. Implementation and usage of bfieldtools
Zetter, R., J. Mäkinen, A., Iivanainen, J., Zevenhoven, K. C. J., Ilmoniemi, R. J., & Parkkonen, L. (2020) · Journal of Applied Physics · doi:10.1063/5.0016087 · Cited by 45
Quantum magnetic gradiometer with entangled twin light beams
Wu, S., Bao, G., Guo, J., Chen, J., Du, W., Shi, M., Yang, P., Chen, L. Q., & Zhang, W. (2023) · Science Advances · doi:10.1126/sciadv.adg1760 · Cited by 60
Miniature Biplanar Coils for Alkali-Metal-Vapor Magnetometry
Tayler, M. C. D., Mouloudakis, K., Zetter, R., Hunter, D., Lucivero, V. G., Bodenstedt, S., Parkkonen, L. T., & Mitchell, M. W. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.014036 · Cited by 51
Early seizure detection for closed loop direct neurostimulation devices in epilepsy
Dümpelmann, M. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab094a · Cited by 51
Compact multi-channel optically pumped magnetometer for bio-magnetic field imaging
Yuan, Z., Liu, Y., Xiang, M., Gao, Y., Suo, Y., Ye, M., & Zhai, Y. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.109534 · Cited by 45
Vector Magnetometry Exploiting Phase-Geometry Effects in a Double-Resonance Alignment Magnetometer
Ingleby, S. J., O’Dwyer, C., Griffin, P. F., Arnold, A. S., & Riis, E. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.034035 · Cited by 45
Application of VCSEL in Bio-Sensing Atomic Magnetometers
Zhou, P., Quan, W., Wei, K., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12121098 · Cited by 42
Synergies between Hyperpolarized NMR and Microfluidics: A Review
Eills, J., Hale, W. G., & Utz, M. (2021) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2021.09.001 · Cited by 46
Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method
Chen, Y., Zhao, L., Zhang, N., Yu, M., Ma, Y., Han, X., Zhao, M., Lin, Q., Yang, P., & Jiang, Z. (2022) · Optics Express · doi:10.1364/oe.450571 · Cited by 42
Perry, A. R., Bulatowicz, M. D., Larsen, M., Walker, T. G., & Wyllie, R. (2020) · Optics Express · doi:10.1364/oe.408486 · Cited by 39
Self-citationIn-Situ Measurement of Electrical-Heating-Induced Magnetic Field for an Atomic Magnetometer
Lu, J., Wang, J., Yang, K., Zhao, J., Quan, W., Han, B., & Ding, M. (2020) · Sensors · doi:10.3390/s20071826 · Cited by 43
Wang, J., Song, X., Le, Y., Wu, W., Zhou, B., & Ning, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3015562 · Cited by 37
“Especially with the development towards miniaturization [7], [8], the coil structure becomes one of the essential factors that limit the physical package of the whole sensor.”
BackgroundMa, Y., Qiao, Z., Yu, M., Wang, Y., Chen, Y., Luo, G., Yang, P., Lin, Q., Zhao, L., Zhang, Y., et al. (2022) · Applied Physics Letters · doi:10.1063/5.0105945 · Cited by 35
Magnetic field interference suppression for minimized SERF atomic magnetometer
Jia, L., Song, X., Suo, Y., Li, J., Long, T., & Ning, X. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114188 · Cited by 37
Ma, Y., Chen, Y., Zhao, L., Luo, G., Yu, M., Wang, Y., Guo, J., Yang, P., Lin, Q., & Jiang, Z. (2022) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2022.169495 · Cited by 35
Optimal buffer gas pressure in dual-beam spin-exchange relaxation-free magnetometers
Lu, J., Zhang, S., Zhou, Y., Yan, Y., Lu, F., Wang, K., Zhai, Y., & Ye, M. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113928 · Cited by 34
Stable Atomic Magnetometer in Parity-Time Symmetry Broken Phase
Zhang, X., Hu, J., & Zhao, N. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.023201 · Cited by 33
Optical Parameter Decoupling and Optimization for Elliptically Polarized Atomic Magnetometer
Yan, Y., Zhang, S., Liu, Z., Zhan, D., Liu, Z., Li, X., Zhou, Y., & Lu, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3343783 · Cited by 35
“Although the elliptically polarized AM scheme has shown considerable promise in various applications, its sensitivity has not shown obvious advantages compared with the sensitivity of the optical absorption-based scheme (10–20 fT/Hz 1 / 2 ) [32], [33], [34], [35], [36], [37].”
BackgroundHigh-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer
Yao, H., Maddox, B., & Renzoni, F. (2022) · Optics Express · doi:10.1364/oe.476016 · Cited by 34
Probe noise characteristics of the spin-exchange relaxation-free (SERF) magnetometer
Xing, B., Sun, C., Liu, Z., Zhao, J., Lu, J., Han, B., & Ding, M. (2021) · Optics Express · doi:10.1364/oe.416797 · Cited by 30
Combining video telemetry and wearable MEG for naturalistic imaging
O’Neill, G. C., Seymour, R. A., Mellor, S., Alexander, N., Tierney, T. M., Bernachot, L., Hnazaee, M. F., Spedden, M. E., Timms, R. C., Bush, D., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00495 · Cited by 30
“…of cryogen-free sensors, particularly optically pumped magnetometers (OPMs; Knappe et al., 2016; Osborne et al., 2018; Shah and Wakai, 2013; Sheng et al., 2017), have led to the rapid development of a new generation of optically pumped (OP) MEG systems ( Borna et al., 2017; Boto et al.,…”
Ge, X., Liu, G., Fan, W., Duan, L., Ma, L., Quan, J., Liu, J., & Quan, W. (2025) · Measurement · doi:10.1016/j.measurement.2025.117123 · Cited by 29
Design and Analysis of a High-Sensitivity Atomic Magnetic Gradiometer With Adjustable Baseline
Zhang, Y., Tang, J., Xu, X., Wang, Z., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3544375 · Cited by 27
“Sheng et al. [28] designed a gradiometer that consisted of two chip-scale magnetometers with a baseline length of 20 mm.”
Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography
Li, J., Du, P., Fu, J., Wang, X.-T., Zhou, Q., & Wang, R. (2019) · Chinese Physics B · doi:10.1088/1674-1056/28/4/040703 · Cited by 27
Synchronous measurement of inertial rotation and magnetic field using a K−Rb−Ne21 comagnetometer
Quan, W., Wei, K., Zhao, T., Li, H., & Zhai, Y. (2019) · Physical Review A · doi:10.1103/physreva.100.012118 · Cited by 27
100 pT/cm single-point MEMS magnetic gradiometer from a commercial accelerometer
Javor, J., Stange, A., Pollock, C., Fuhr, N. E., & Bishop, D. J. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0173-z · Cited by 28
Analysis and suppression of magnetic field interference for SERF atomic magnetometer
Jia, L., Li, J., Song, X., Qi, S., Suo, Y., Long, T., Dai, Y., & Ning, X. (2024) · Measurement · doi:10.1016/j.measurement.2024.114266 · Cited by 27
Zhang, G., Zeng, H., Tan, G., & Lin, Q. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3156814 · Cited by 26
Optical pumping enhancement of a free-induction-decay magnetometer
Hunter, D., Mrozowski, M. S., McWilliam, A., Ingleby, S. J., Dyer, T., Griffin, P. F., & Riis, E. (2023) · Journal of the Optical Society of America B · doi:10.1364/josab.501086 · Cited by 27
Automatic coregistration of MRI and on-scalp MEG
Gu, W., Ru, X., Li, D., He, K., Cui, Y., Sheng, J., & Gao, J. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109181 · Cited by 26
Noninvasive magnetocardiography of a living rat based on a diamond quantum sensor
Yu, Z., Xie, Y., Jin, G., Zhu, Y., Zhang, Q., Shi, F., Wan, F.-Y., Luo, H., Tang, A., & Rong, X. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.064028 · Cited by 29
Gradient phase and amplitude errors in atomic magnetic gradiometers for biomagnetic imaging systems
Yuan, Z., Lin, S., Liu, Y., Tang, J., Long, T., & Zhai, Y. (2024) · iScience · doi:10.1016/j.isci.2024.109250 · Cited by 24
Hardware-Based Interference Suppression Techniques for OPM-MEG: A Review
Jia, L., Li, J., Song, X., Ning, X., Yang, J., Qi, S., Long, T., Wu, Z., & Wang, R. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3509679 · Cited by 29
An optically pumped magnetic gradiometer for the detection of human biomagnetism
Cook, H., Bezsudnova, Y., Koponen, L. M., Jensen, O. B., Barontini, G., & Kowalczyk, A. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad3d81 · Cited by 25
“Semi-intrinsic OPMGs ∗ a.u.kowalczyk@bham.ac.uk use a single laser beam split into either two [33] or multiple measurement channels [34].”
BackgroundGal, G. L., Rouve, L.-L., & Palacios-Laloy, A. (2021) · Applied Physics Letters · doi:10.1063/5.0047124 · Cited by 24
Indium Tin Oxide Non-Magnetic Heating Film for Miniaturized SERF Gradient Magnetometer
Liu, Z., Zhang, C., Yuan, H., Yin, K., Yang, Y., Yan, Y., Wang, Y., Zhou, B., Ning, X., & Han, B. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3076133 · Cited by 22
Gradiometer Using Separated Diamond Quantum Magnetometers
MASUYAMA, Y., Suzuki, K., Hekizono, A., Iwanami, M., Hatano, M., Iwasaki, T., & Ohshima, T. (2021) · Sensors · doi:10.3390/s21030977 · Cited by 23
Jia, L., Li, J., Song, X., Qi, S., Long, T., Wu, Z., Wang, R., & Ning, X. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3522373 · Cited by 37
“…xM t ) is applied to the x -axis only, and LIA demodulates the first harmonic of ω xM only; the output signal changes caused by the x -axis target field are fed back to controller; and the output of controller is applied to the x -axis magnetic field coil only to track and cancel target field [37].”
Signal-enhanced spin-exchange relaxation-free atomic magnetometer
Li, C., Tang, J., Zhang, Y., Yuan, Z., Li, J., Zhai, Y., & Liu, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114247 · Cited by 22
Four-channel optically pumped magnetometer for a magnetoencephalography sensor array
Iivanainen, J., Carter, T. R., Dhombridge, J. E., Read, T. S., Campbell, K., Abate, Q., Ridley, D. M., Borna, A., & Schwindt, P. D. D. (2024) · Optics Express · doi:10.1364/oe.517961 · Cited by 18
Xing, B., Lu, J., Sun, C., Yu, T., Wu, Y., Gao, Y., & Han, B. (2022) · Optics Express · doi:10.1364/oe.449951 · Cited by 18
Xiang, J., Yu, X., Bonnette, S., Anand, M., Riehm, C. D., Schlink, B. R., Diekfuss, J. A., Myer, G. D., & Jiang, Y. (2023) · Brain Sciences · doi:10.3390/brainsci13040663 · Cited by 17
“Since this approach does not need to physically construct gradiometers with two OPMs (or vapor cells) [14,15], it avoids the potential cross-talk and interference between two closely placed OPMs.”
BackgroundMethodInfluentialOptically pumped magnetometer with dynamic common mode magnetic field compensation
Wang, Y., Niu, Y., & Ye, C. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.113195 · Cited by 18
Zhang, S., Zhou, Y., Chai, Z., Liu, Q., Yin, K., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3232658 · Cited by 17
“Typical AMs usually use distributed feedback (DFB) laser or distributed Bragg reflector (DBR) laser as the pump light source [23], [24].”
BackgroundSelf-powered elementary hybrid magnetoelectric sensor
Gerhardt, M., Zimoch, L., Dorn, C., Elzenheimer, E., Bald, C., Lerg, T., Hoffmann, J., Kaps, S., Höft, M., Schmidt, G. U., et al. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108720 · Cited by 15
A high performance active noise control system for magnetic fields
Pyragius, T., & Jensen, K. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062650 · Cited by 19
Yu, Q.-Q., Liu, S.-Q., Wang, X.-K., & Sheng, D. (2023) · Physical Review A · doi:10.1103/physreva.107.043110 · Cited by 15
Self-citationDong, H., Ye, H., Hu, M., & Ma, Z. (2023) · Micromachines · doi:10.3390/mi15010059 · Cited by 15
“In 2017, D. Sheng et al. designed an atomic magnetic gradiometer using two micro-fabricated vapor cells, vacuum thermal isolation and laser heating [38].”
BackgroundMethodInfluentialLiu, S.-Q., Yu, Q.-Q., Zhou, H., & Sheng, D. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.044062 · Cited by 15
Self-citationLaser Heating Method for an Alkali Metal Atomic Cell with Heat Transfer Enhancement
Li, Y., Zhou, G., Tian, S., Liu, X., Dong, X., & Gao, X. (2023) · Photonics · doi:10.3390/photonics10060637 · Cited by 15
“Mhaskar et al. [24] and Sheng [25] installed colored filters on both sides of the vapor cell to improve the laser absorption efficiency, but there is still residual energy that has not been utilized.”
Interactions between nonresonant rf fields and atoms with strong spin-exchange collisions
Hao, C., Qiu, Z., Sun, Q., Zhu, Y., & Sheng, D. (2019) · Physical Review A · doi:10.1103/physreva.99.053417 · Cited by 14
Self-citationIn-Situ Relaxation Rate Measurement in Magnetic Modulated Atomic Magnetometers
Yin, K., Zhou, B., Lu, J., Lu, F., Zhang, S., Yan, Y., & Ye, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3131734 · Cited by 15
Atom-based quantum sensing of electromagnetic fields
Kitching, J. E., Shaffer, J. P., & Budker, D. (2025) · Optica · doi:10.1364/optica.569334 · Cited by 18
Self-citationChai, C., Yang, X. M., Zheng, Y., Heyat, M. B. B., Li, Y., Yang, D.-B., Chen, Y.-H., & Sawan, M. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117321 · Cited by 15
Coherent population trapping in optically thin 133Cs atomic vapor in a finite-size cell
Баранцев, К. А., Bozhokin, S. V., Kuraptsev, A. S., Litvinov, A. N., & Sokolov, I. M. (2021) · Journal of the Optical Society of America B · doi:10.1364/josab.412513 · Cited by 13
Temperature characteristics of Rb-N2 single-beam magnetometer with different buffer gas pressures
Zhang, S., Zhou, Y., Lu, F., Yan, Y., Wang, W., Zhou, B., Zhai, Y., Lu, J., & Ye, M. (2023) · Measurement · doi:10.1016/j.measurement.2023.112860 · Cited by 13
Magnetic Gradient Measurement Using Micro-Fabricated Shaped Rubidium Vapor Cell
Ji, Y., Shang, J., Zhang, J., & Li, G. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2916311 · Cited by 13
“For better target field spatial information in these applications, magnetic gradient measurement is of great importance [9].”
BackgroundWu, Z., Zhang, J., He, M., Ren, B., Wang, Z., Chen, W., Ou, Z., Yue, H., Zhou, X., & Liu, Y. (2023) · Optics Express · doi:10.1364/oe.484984 · Cited by 13
Free-induction-decay magnetometer based on synchronous optical pumping and RF pulse modulation
Xu, J., Jiang, L., Liu, J., Liu, J., Chen, Y., Zhu, J., Fang, C., Shao, Q., Zou, Y., & Bai, H. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00373-y · Cited by 12
“Optically pumped magnetometers utilizing the spin-exchange relaxation-free (SERF) mechanism provide sensitivity comparable to superconducting quantum interference devices (SQUIDs) and have been developed for applications in near-zero field [5–8].”
Schneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_78 · Cited by 12
Towards non-invasive imaging through spinal-cord generated magnetic fields
Spedden, M. E., O’Neill, G. C., Tierney, T. M., West, T. O., Schmidt, M., Mellor, S., Farmer, S. F., Bestmann, S., & Barnes, G. R. (2024) · Frontiers in Medical Technology · doi:10.3389/fmedt.2024.1470970 · Cited by 12
Ma, Y., Chen, Y., Zhao, L., Yu, M., Wang, Y., Guo, J., Yang, P., Lin, Q., & Jiang, Z. (2022) · Measurement Science and Technology · doi:10.1088/1361-6501/ac72f9 · Cited by 11
“In order to achieve the SERF regime without introducing other stray electromagnetic fields, an optical heating method is adopted for the vapor cell, and this process is accomplished through the absorption of 1550 nm light by a black filter attached to the cell’s side [1].”
Optimizing longitudinal spin relaxation in miniaturized optically pumped magnetometers
McWilliam, A., Dyer, S., Hunter, D., Mrozowski, M. S., Ingleby, S. J., Sharp, O., Burt, D. P., Griffin, P. F., McGilligan, J. P., & Riis, E. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.064024 · Cited by 9
Qi, P.-L., Geng, X., Yang, G., Huang, G., & Li, G. (2020) · Journal of the Optical Society of America B · doi:10.1364/josab.404651 · Cited by 10
Fast measurement of magnetic gradient based on four-channel optically pumped atomic magnetometer
Zhang, Y., Tang, J., Li, C., Zhao, B., Li, L., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114591 · Cited by 9
Ultra-sensitive single-beam atom-optical magnetometer using weak measurement method
Chacko, V. F. T. J., Suna, R. R., Madhu, P. K., Viswanathan, N. K., & Rajalakshmi, G. (2019) · AIP Advances · doi:10.1063/1.5090581 · Cited by 9
Metadata
- Authors
- Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2017-01-16
- Volume
- 110
- Issue
- 3
- Pages
- 031106-031106
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- PMC
- PMC5250637
- OpenAlex
- W2572181495
- Cited by
- 179
- References
- 27
- Citations by year
- 2026: 13 · 2025: 26 · 2024: 15 · 2023: 30 · 2022: 25 · 2021: 25 · 2020: 17 · 2019: 23 · 2018: 2 · 2017: 3
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Applied Physics Letters (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Institutes of Health (1R01EB019440,1R44NS090894,R01NS094604)
- National Institute of Standards and Technology (Embedded Standards/NIST on a Chip initiative (EBS14))
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- magnetic gradiometer, atomic magnetometer, microfabrication, spin-exchange relaxation-free, alkali metal vapors, optical pumping, chip-scale sensors, magnetic field gradient measurement, common-mode noise suppression, compensation coils, intensity inhomogeneity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.