Numerical investigation of aerosol transport in a classroom with relevance to COVID-19
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The present study investigates aerosol transport and surface deposition in a realistic classroom environment using computational fluid-particle dynamics simulations. Effects of particle size, aerosol source location, glass barriers, and windows are explored. While aerosol transport in air exhibits some stochasticity, it is found that a significant fraction (24%–50%) of particles smaller than 15 µm exit the system within 15 min through the air conditioning system. Particles larger than 20 µm almost entirely deposit on the ground, desks, and nearby surfaces in the room. Source location strongly influences the trajectory and deposition distribution of the exhaled aerosol particles and affects the effectiveness of mitigation measures such as glass barriers. Glass barriers are found to reduce the aerosol transmission of 1 µm particles from the source individual to others separated by at least 2.4 m by ∼92%. By opening windows, the particle exit fraction can be increased by ∼38% compared to the case with closed windows and reduces aerosol deposition on people in the room. On average, ∼69% of 1 µm particles exit the system when the windows are open.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-equation eddy-viscosity turbulence models for engineering applications
Menter, F. R. (1994) · AIAA Journal · doi:10.2514/3.12149 · Cited by 21,593
The numerical computation of turbulent flows
Launder, B. E., & Spalding, D. B. (1974) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(74)90029-2 · Cited by 12,833
An investigation of particle trajectories in two-phase flow systems
Morsi, S. A., & Alexander, A. J. (1972) · Journal of Fluid Mechanics · doi:10.1017/s0022112072001806 · Cited by 3,089
Development of turbulence models for shear flows by a double expansion technique
Yakhot, V., Orszag, S. A., Thangam, S., Gatski, T. B., & Speziale, C. G. (1992) · Physics of Fluids A: Fluid Dynamics · doi:10.1063/1.858424 · Cited by 2,832
How can airborne transmission of COVID-19 indoors be minimised?
Morawska, L., Tang, J. W., Bahnfleth, W., Bluyssen, P. M., Boerstra, A., Buonanno, G., Cao, J., Dancer, S., Floto, A., Franchimon, F., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105832 · Cited by 1,343
Jayaweera, M., Perera, H., Gunawardana, B., & Manatunge, J. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109819 · Cited by 1,238
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
Stadnytskyi, V., Bax, C. E., Bax, A., & Anfinrud, P. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2006874117 · Cited by 1,077
Ramponi, R., & Blocken, B. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.01.004 · Cited by 555
Slip Correction Measurements of Spherical Solid Aerosol Particles in an Improved Millikan Apparatus
Allen, M. D., & Raabe, O. G. (1985) · Aerosol Science and Technology · doi:10.1080/02786828508959055 · Cited by 504
Mittal, R., Ni, R., & Seo, J.-H. (2020) · Journal of Fluid Mechanics · doi:10.1017/jfm.2020.330 · Cited by 494
Mittal, R., Ni, R., & Seo, J. (2020) · Europe PMC (PubMed Central) · Cited by 483
Vuorinen, V., Aarnio, M., Alava, M., Alopaeus, V., Atanasova, N., Auvinen, M., Balasubramanian, N., Bordbar, H., Erästö, P., Grande, R., et al. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104866 · Cited by 472
Zhao, B., Zhang, Y., Li, X., Yang, X., & Huang, D. (2003) · Building and Environment · doi:10.1016/j.buildenv.2003.08.002 · Cited by 447
Visualizing Speech-Generated Oral Fluid Droplets with Laser Light Scattering
Anfinrud, P., Stadnytskyi, V., Bax, C. E., & Bax, A. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2007800 · Cited by 409
Characterizations of particle size distribution of the droplets exhaled by sneeze
Han, Z. Y., Weng, W. G., & Huang, Q. Y. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0560 · Cited by 383
On respiratory droplets and face masks
Dbouk, T., & Drikakis, D. (2020) · Physics of Fluids · doi:10.1063/5.0015044 · Cited by 350
Lindsley, W. G., Pearce, T. A., Hudnall, J. B., Davis, K. A., Davis, S. M., Fisher, M. A., Khakoo, R., Palmer, J. E., Clark, K. E., Celik, I., et al. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.684582 · Cited by 300
Longest, P. W., & Xi, J. (2007) · Aerosol Science and Technology · doi:10.1080/02786820701203223 · Cited by 245
Sneezing and asymptomatic virus transmission
Busco, G., Yang, S. R., Seo, J., & Hassan, Y. A. (2020) · Physics of Fluids · doi:10.1063/5.0019090 · Cited by 188
Can a toilet promote virus transmission? From a fluid dynamics perspective
Li, Y.-Y., Wang, J.-X., & Chen, X. (2020) · Physics of Fluids · doi:10.1063/5.0013318 · Cited by 180
Review of indoor aerosol generation, transport, and control in the context of COVID‐19
Kohanski, M. A., Lo, L. J., & Waring, M. S. (2020) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22661 · Cited by 176
Qian, H., & Li, Y. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00653.x · Cited by 149
An air distribution optimization of hospital wards for minimizing cross-infection
Wang, J., Cao, X. S., & Chen, Y. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.123431 · Cited by 92
Habilomatis, G., & Chaloulakou, A. (2015) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2015.03.089 · Cited by 65
Talaat, K., Xi, J., Baldez, P., & Hecht, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-54040-1 · Cited by 43
Self-citationTransport and trajectory of cough-induced bimodal aerosol in an air-conditioned space
Zhang, B., Guo, G., Zhu, C., Ji, Z., & Lin, C.-H. (2020) · Indoor and Built Environment · doi:10.1177/1420326x20941166 · Cited by 40
Wurie, F. B., de Waroux, O. L. P., Brande, M., DeHaan, W. H., Holdgate, K., Mannan, R., Milton, D. K., Swerdlow, D. I., & Hayward, A. C. (2013) · F1000Research · doi:10.12688/f1000research.2-14.v1 · Cited by 33
Visualization of local deposition of nebulized aerosols in a human upper respiratory tract model
Xi, J., Yang, T., Talaat, K., Wen, T., Zhang, Y., Klozik, S., & Peters, S. (2017) · Journal of Visualization · doi:10.1007/s12650-017-0456-0 · Cited by 27
Self-citation
Cited by
COVID-19 spread in a classroom equipped with partition – A CFD approach
Mirzaie, M., Lakzian, E., Khan, A., Warkiani, M. E., Mahian, O., & Ahmadi, G. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126587 · Cited by 186
Metadata
- Authors
- Abuhegazy, M., Talaat, K., Anderoglu, O., & Poroseva, S. V.
- Venue
- Physics of Fluids
- Publisher
- AIP Publishing
- Published
- 2020-10-01
- Volume
- 32
- Issue
- 10
- Pages
- 103311-103311
- ISSN
- 1070-6631 (ISSN-L)
- 1089-7666
- OpenAlex
- W3093653593
- Cited by
- 251
- References
- 30
- FWCI
- 21.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.