Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Peptide sequence analysis using a combination of gas-phase ion/ion chemistry and tandem mass spectrometry (MS/MS) is demonstrated. Singly charged anthracene anions transfer an electron to multiply protonated peptides in a radio frequency quadrupole linear ion trap (QLT) and induce fragmentation of the peptide backbone along pathways that are analogous to those observed in electron capture dissociation. Modifications to the QLT that enable this ion/ion chemistry are presented, and automated acquisition of high-quality, single-scan electron transfer dissociation MS/MS spectra of phosphopeptides separated by nanoflow HPLC is described.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electron capture dissociation (ECD) [114] and electron transfer dissociation (ETD) [115], on the other hand, are nonergodic techniques for protein fragmentation.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [115]
Citations
Cites
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Proteomic analysis of post-translational modifications
Mann, M., & Jensen, O. N. (2003) · Nature Biotechnology · doi:10.1038/nbt0303-255 · Cited by 2,134
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Phosphoproteome analysis by mass spectrometry and its application to Saccharomyces cerevisiae
Ficarro, S. B., McCleland, M. L., Stukenberg, P. T., Burke, D. J., Ross, M. M., Shabanowitz, J., Hunt, D. F., & White, F. M. (2002) · Nature Biotechnology · doi:10.1038/nbt0302-301 · Cited by 1,636
Self-citationElectron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
A two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Self-citationZubarev, R. A., Kruger, N. A., Fridriksson, E. K., Lewis, M. A., Horn, D. M., Carpenter, B. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja981948k · Cited by 557
Reactions of polypeptide ions with electrons in the gas phase
Zubarev, R. A. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10042 · Cited by 431
Mirgorodskaya, E., Roepstorff, P., & Zubarev, R. A. (1999) · Analytical Chemistry · doi:10.1021/ac990578v · Cited by 381
Probability-Based Validation of Protein Identifications Using a Modified SEQUEST Algorithm
MacCoss, M. J., Wu, C. C., & Yates, J. R. (2002) · Analytical Chemistry · doi:10.1021/ac025826t · Cited by 377
Cited by
Items 601–700 of 1,005
Bioprospecting the American Alligator (Alligator mississippiensis) Host Defense Peptidome
Bishop, B., Juba, M. L., Devine, M., Barksdale, S. M., Rodriguez, C. A., Chung, M. C., Russo, P. S., Vliet, K. A., Schnur, J. M., & van Hoek, M. L. (2015) · PLoS ONE · doi:10.1371/journal.pone.0117394 · Cited by 57
“The sequences of captured native intact peptides, including potential CAMPs, were elucidated using an Orbitrap Elite mass spectrometer equipped with ETD fragmentation, which has been shown to be ideally suited for fragmenting large, highly charged peptides [14, 15].”
MethodGas-phase regiocontrolled generation of charged amino acid and peptide radicals
Wee, S., Mortimer, A., Moran, D., Wright, A., Barlow, C. K., O’Hair, R. A. J., Radom, L., & Easton, C. J. (2006) · Chemical Communications · doi:10.1039/b608724h · Cited by 55
Zhang, L., & Reilly, J. P. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.026 · Cited by 59
“Many techniques and reactions have been developed to generate biomolecular radicals in the gas phase, including ion–ion (electron) interactions [11, 12], dissociation of peptide–metal complexes [13–16], and chemical modification with peroxycarbamate, azo, iodo, and nitroso functional groups along with ultraviolet (UV)…”
BackgroundBarlow, C. K., & O’Hair, R. A. J. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1469 · Cited by 54
Hersberger, K. E., & Håkansson, K. (2012) · Analytical Chemistry · doi:10.1021/ac301536r · Cited by 54
Urinary proteome pattern in children with renal Fanconi syndrome
Drube, J., Schiffer, E., Mischak, H., Kemper, M. J., Neuhaus, T. J., Pape, L., Lichtinghagen, R., & Ehrich, J. H. H. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp063 · Cited by 54
Neuropeptidomics Strategies for Specific and Sensitive Identification of Endogenous Peptides
Fälth, M., Sköld, K., Svensson, M., Nilsson, A., Fenyö, D., & Andrén, P. E. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700016-mcp200 · Cited by 58
“The described methodology will benefit from using high mass accuracy instruments like orbitrap (51– 53), FTMS (54), and time of flight (55) and will benefit greatly from the use of complementary fragmentation techniques such as electron capture dissociation (56, 57) and electron transfer dissociation ( 58 ).”
MethodNishikaze, T., Kawabata, S.-I., & Tanaka, K. (2014) · Analytical Chemistry · doi:10.1021/ac500340t · Cited by 55
Origins, Technological Development, and Applications of Peptidomics
Schrader, M. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-7537-2_1 · Cited by 60
Lodge, J. M., Schauer, K. L., Brademan, D. R., Riley, N. M., Shishkova, E., Westphall, M. S., & Coon, J. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00705 · Cited by 55
Self-citationThe Hitchhiker's guide to glycoproteomics
Oliveira, T., Thaysen‐Andersen, M., Packer, N. H., & Kolarich, D. (2021) · Biochemical Society Transactions · doi:10.1042/bst20200879 · Cited by 54
Madsen, J. A., & Brodbelt, J. S. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.10.018 · Cited by 58
“MS/MS has recently been used for the analysis of these supercharged ions, revealing interesting fragmentation trends such as enhanced formation of diagnostic ions upon CID of the highest supercharged state of proteins [38] and increased sequence coverage upon ETD of the highest supercharged state of tryptic peptides […”
BackgroundRecent advances in the MS analysis of glycoproteins: Theoretical considerations
Lazar, I. M., Lazar, A. C., Cortes, D. F., & Kabulski, J. L. (2010) · Electrophoresis · doi:10.1002/elps.201000393 · Cited by 53
Kandasamy, K., Pandey, A., & Molina, H. (2009) · Analytical Chemistry · doi:10.1021/ac9006107 · Cited by 54
Shotgun Proteomics in Neuroscience
Liao, L., McClatchy, D. B., & Yates, J. R. (2009) · Neuron · doi:10.1016/j.neuron.2009.06.011 · Cited by 60
Proteomic Analyses of Host and Pathogen Responses during Bovine Mastitis
Boehmer, J. L. (2011) · Journal of Mammary Gland Biology and Neoplasia · doi:10.1007/s10911-011-9229-x · Cited by 61
“Electron-transfer dissociation (ETD), which is a superior fragmentation strategy for the analysis of PTMs, however, was recently introduced, and shows promise as a strategy for the characterization of protein modification during disease [48].”
BackgroundAsakawa, D., & Takayama, M. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0131-y · Cited by 53
“MALDI-ISD shares some similarities with radicalinduced fragmentation, electron capture dissociation (ECD) [15], and electron transfer dissociation (ETD) [ 16 ].”
BackgroundSelective Covalent Bond Formation in Polypeptide Ions via Gas-Phase Ion/Ion Reaction Chemistry
Han, H., & McLuckey, S. A. (2009) · Journal of the American Chemical Society · doi:10.1021/ja904812d · Cited by 53
Comparative glycoproteomics: approaches and applications
Wei, X. L., & Li, L. (2008) · Briefings in Functional Genomics and Proteomics · doi:10.1093/bfgp/eln053 · Cited by 58
“One of the unique strengths of the QUIC-Tag strategy is the use of electron-transfer dissociation (ETD), a relatively new fragmentation method based on radical initiated backbone cleavage [27].”
MethodTrnka, M. J., & Burlingame, A. L. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.003764 · Cited by 53
Venomics-Accelerated Cone Snail Venom Peptide Discovery
Himaya, S. W. A., & Lewis, R. J. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19030788 · Cited by 53
“However, alternative methods such as electron transfer dissociation [62] are becoming more widely available and promise improved fragmentation of larger and modified peptides.”
A Calibration Routine for Efficient ETD in Large-Scale Proteomics
Rose, C. M., Rush, M. J. P., Riley, N. M., Merrill, A. E., Kwiecien, N. W., Holden, D. D., Mullen, C., Westphall, M. S., & Coon, J. J. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1183-1 · Cited by 53
“Now, one decade since its first description, ETD is commercially available on multiple MS platforms by a variety of vendors including: rf 3D quadrupole ion traps [4, 5], radial ejection rf linear (2D) quadrupole ion traps (QLT) [2, 3], hybrid QLT-Orbitraps [6, 7], quadrupole mass filter Fourier transform ion cyclotron…”
InfluentialSelf-citationHan, H., Xia, Y., Yang, M., & McLuckey, S. A. (2008) · Analytical Chemistry · doi:10.1021/ac7022734 · Cited by 57
Signal processing by protein tyrosine phosphorylation in plants
Ghélis, T. (2011) · Plant Signaling & Behavior · doi:10.4161/psb.6.7.15261 · Cited by 61
Neutral Fragment Mass Spectra via Ambient Thermal Dissociation of Peptide and Protein Ions
Chen, H., Eberlin, L. S., & Cooks, R. G. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067712v · Cited by 54
Lima, V. V., Rigsby, C. S., Hardy, D. M., Webb, R. C., & Tostes, R. C. (2009) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2009.09.004 · Cited by 62
“Because direct observation of the O-GlcNAc moiety by mass spectrometry during collision-induced dissociation is difficult, as the glycosidic linkage is labile and readily cleaved,(75) alternative and newer approaches, such as b-elimination followed by Michael addition with dithiothreitol, electron transfer dissociatio…”
MethodRadical‐driven peptide backbone dissociation tandem mass spectrometry
Oh, H. B., & Moon, B. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21426 · Cited by 55
Wöhlbrand, L., Trautwein, K., & Rabus, R. (2013) · PROTEOMICS · doi:10.1002/pmic.201300175 · Cited by 53
“ETD utilizes ion/ion chemistry to transfer an electron from a radical anion (commonly derived from fluoranthene) to a protonated peptide [119].”
BackgroundPerspectives of Comprehensive Phosphoproteome Analysis Using Shotgun Strategy
Wang, F., Song, C., Cheng, K., Jiang, X., Ye, M., & Zou, H. (2011) · Analytical Chemistry · doi:10.1021/ac201833j · Cited by 54
Khakinejad, M., Kondalaji, S. G., Maleki, H., Arndt, J. R., Donohoe, G. C., & Valentine, S. J. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0990-0 · Cited by 55
Lam, A. K. Y., Ryzhov, V., & O’Hair, R. A. J. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.01.027 · Cited by 55
“The former are formed via electron capture dissociation (ECD) [27] and electron-transfer dissociation (ETD) [ 28 ] and their mechanism of fragmentation has been the subject of intense scrutiny over the past decade [29 –33].”
BackgroundFragmentation ofα-radical cations of arginine-containing peptides
Laskin, J., Yang, Z., Ng, C. M. D., & Chu, I. K. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.12.021 · Cited by 55
“electron-transfer processes [1–5, 9], hydrogen deficient radical anions [M nH] generated by electron”
BackgroundBaker, P. R., Medzihradszky, K. F., & Chalkley, R. J. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.000422 · Cited by 52
“ETD (4) and the related fragmentation process electron capture dissociation (ECD) (5) have been demonstrated to have particular advantages for the analysis of large peptides and small proteins (6–8) as well as the analysis of peptides bearing labile post-translational modifications (9–11).”
BackgroundCristobal, A., Hennrich, M. L., Giansanti, P., Goerdayal, S. S., Heck, A. J. R., & Mohammed, S. (2012) · The Analyst · doi:10.1039/c2an35445d · Cited by 52
Mischerikow, N., Altelaar, M. A. F., Navarro, J. D., Mohammed, S., & Heck, A. J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900619-mcp200 · Cited by 53
“If rearrangement had taken place, in all three peptide groups (identical position, different position, and ambiguous position), it would only have affected the CID spectra but not the ETcaD spectra because ETD has limited intramolecular energy dissipation (47).”
BackgroundSasaki, K., Osaki, T., & Minamino, N. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.017400 · Cited by 52
Weichman, M. L., DeVine, J. A., Levine, D. S., Kim, J. B., & Neumark, D. M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1520862113 · Cited by 52
“Anionic anthracene derivatives in various protonation states are also used in electron transfer dissociation mass spectrometry as an electron source to induce fragmentation of peptide backbones (27).”
BackgroundRiley, N. M., Westphall, M. S., Hebert, A. S., & Coon, J. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00213 · Cited by 52
Self-citationWeisbrod, C. R., Kaiser, N. K., Syka, J. E. P., Early, L., Mullen, C., Dunyach, J.-J., English, A. M., Anderson, L. C., Blakney, G. T., Shabanowitz, J., et al. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1702-3 · Cited by 49
“[9] by use of an axial rf pseudopotential for charge signindependent trapping.”
Self-citationIdentification of Posttranslational Modifications (PTMs) of Proteins by Mass Spectrometry
Aslebagh, R., Wormwood, K. L., Channaveerappa, D., Wetie, A. G. N., Woods, A. G., & Darie, C. C. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-15950-4_11 · Cited by 52
Fundamentals of Ion Mobility-Mass Spectrometry for the Analysis of Biomolecules
Morris, C. B., Poland, J. C., May, J. C., & MCLEAN, J. A. J. (2019) · Methods in molecular biology · doi:10.1007/978-1-0716-0030-6_1 · Cited by 57
“Multiply charged ions have also improved detection limits for Fourier transform MS (FTMS) techniques [66, 67], improved the ion fragment yields for traditional collisional activation experiments (collision-induced dissociation, CID) [68], and have enabled electron-induced fragmentation techniques such as electron capt…”
BackgroundExploring the structure and dynamics of macromolecular complexes by native mass spectrometry
Boeri Erba, E., Signor, L., & Petosa, C. (2020) · Journal of Proteomics · doi:10.1016/j.jprot.2020.103799 · Cited by 51
“ETD is a fragmentation method based on the transfer of electrons originating from radical anions [96, 118, 119].”
Chakraborty, T., Holm, A. I. S., Hvelplund, P., Nielsen, S. B., Poully, J., Worm, E. S., & Williams, E. R. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.07.018 · Cited by 57
“EC can occur via interactions with thermally generated free electrons [1], collisions with anions [2], or with atoms [3].”
BackgroundAchieving In-Depth Proteomics Profiling by Mass Spectrometry
Ahn, N. G., Shabb, J. B., Old, W. M., & Resing, K. A. (2007) · ACS Chemical Biology · doi:10.1021/cb600357d · Cited by 51
Warnke, S., von Helden, G., & Pagel, K. (2015) · PROTEOMICS · doi:10.1002/pmic.201400480 · Cited by 60
“and therefore greatly increased sequence information can be obtained [2, 3].”
BackgroundChallenges of Determining O-Glycopeptide Heterogeneity: A Fungal Glucanase Model System
Christiansen, M. N., Kolarich, D., Nevalainen, H. K. M., Packer, N. H., & Jensen, P. H. (2010) · Analytical Chemistry · doi:10.1021/ac901717n · Cited by 54
Snovida, S. I., Bodnar, E. D., Viner, R., Saba, J. A., & Perreault, H. (2010) · Carbohydrate Research · doi:10.1016/j.carres.2010.01.006 · Cited by 51
Mirza, S. P., & Olivier, M. (2007) · Physiological Genomics · doi:10.1152/physiolgenomics.00292.2007 · Cited by 51
“The dissociation techniques in top-down proteomics are favored toward electron-capture dissociation (ECD) as implemented on FT-ICR-MS or electron-transfer dissociation (ETD) used in orbitrap instruments.”
MethodOxidative protein labeling in mass-spectrometry-based proteomics
Roeser, J., Bischoff, R., Bruins, A. P., & Permentier, H. P. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3471-8 · Cited by 51
Linear and Differential Ion Mobility Separations of Middle-Down Proteoforms
Garabedian, A., Baird, M. A., Porter, J. E., Fouque, K. J. D., Shliaha, P. V., Jensen, O. N., Williams, T. D., Fernandez-Lima, F. A., & Shvartsburg, A. A. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05224 · Cited by 56
Electron-Based Dissociation Is Needed for O-Glycopeptides Derived from OpeRATOR Proteolysis
Riley, N. M., Malaker, S. A., & Bertozzi, C. R. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02950 · Cited by 52
Campuzano, I. D. G., & Sandoval, W. N. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00036 · Cited by 54
Gross, J. H. (2017) · Springer eBooks · doi:10.1007/978-3-319-54398-7_9 · Cited by 60
Cullen, T. W., Madsen, J. A., Ivanov, P. L., Brodbelt, J. S., & Trent, M. S. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.321737 · Cited by 57
“ETD has proven to be particularly well suited for the identification of post-translational modifications because these labile modifications are often retained on the amino acid side chain during ion dissociation, allowing them to be readily tracked (25, 26).”
BackgroundPhospho‐proteomic analysis of cellular signaling
de Graauw, M., Hensbergen, P. J., & van de Water, B. (2006) · Electrophoresis · doi:10.1002/elps.200600018 · Cited by 51
Na, S., Jeong, J., Park, H., Lee, K., & Paek, E. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800101-mcp200 · Cited by 51
“This is mainly because of peaks related to different types of ions (24) or prompt loss of modification from modified residues (26) during collision-activated dissociation.”
BackgroundHydrogen/Deuterium Exchange Mass Spectrometry: Fundamentals, Limitations, and Opportunities
Konermann, L., & Scrosati, P. M. (2024) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2024.100853 · Cited by 51
“Also, ECD/ETD fragmentation ef fi - ciencies tend to be quite low, necessitating extensive signal averaging.”
Huang, Y., & Dodds, E. D. (2015) · The Analyst · doi:10.1039/c5an01093d · Cited by 50
Mohammed, S., Lorenzen, K., Kerkhoven, R., van Breukelen, B., Vannini, A., Cramer, P., & Heck, A. J. R. (2008) · Analytical Chemistry · doi:10.1021/ac7024283 · Cited by 51
Does Electron Capture Dissociation Cleave Protein Disulfide Bonds?
Ganisl, B., & Breuker, K. (2012) · ChemistryOpen · doi:10.1002/open.201200038 · Cited by 55
Hamidane, H. B., He, H., Tsybin, O. Y., Emmett, M. R., Hendrickson, C. L., Marshall, A. G., & Tsybin, Y. O. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.02.015 · Cited by 54
“Therefore, we selected the class of amphipathic peptides and proteins to probe ECD characteristics, to improve both fundamental and practical aspects of ECD in MS/MS. Projection of ECD Fourier transform ion cyclotron resonance (FT-ICR) MS results to ETD in ion trap MS is considered as a second step and will require es…”
BackgroundInfluentialSobczyk, M. A., & Simons, J. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.05.003 · Cited by 54
Siu, C., Ke, Y., Orlova, G., Hopkinson, A. C., & Siu, K. W. M. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.09.026 · Cited by 53
“C bonds, giving c- and z-type ions, is common in other types of dissociation techniques, namely electroncapture dissociation (ECD) [15] and electron-transfer dissociation (ETD) [16], that produce radical cations as a result of, respectively, electron-capture by or electrontransfer to multiply protonated peptide ions […”
BackgroundLeach, F. E., Ly, M., Laremore, T. N., Wolff, J. J., Perlow, J., Linhardt, R. J., & Amster, I. J. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0428-5 · Cited by 52
“NETD experiments were performed on a 12.0 T Bruker solariX FTMS instrument (Bruker Daltonics, Billerica, MA, USA) fitted with an ESI/MALDI dual source.”
InfluentialMass Spectrometry of Membrane Proteins: A Focus on Aquaporins
Schey, K. L., Grey, A. C., & Nicklay, J. J. (2013) · Biochemistry · doi:10.1021/bi301604j · Cited by 57
Analysis of environmental stress response on the proteome level
Nesatyy, V. J., & Suter, M. J. ‐. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20177 · Cited by 57
Trabjerg, E., Jakobsen, R. U., Mysling, S., Christensen, S., Jørgensen, T. J. D., & Rand, K. D. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01996 · Cited by 53
Advancing Proteomics with ion/ion Chemistry: Mass Spectrometry For Proteomics Analysis
Good, D. M., & Coon, J. J. (2006) · BioTechniques · doi:10.2144/000112194 · Cited by 54
“Initiation and termination of the ion/ion reaction is also controlled by adjustment of these DC bias potentials ( 14 ).”
BackgroundSelf-citationCharacterization of Site-specific N-Glycosylation
Medzihradszky, K. F. (2008) · Humana Press eBooks · doi:10.1007/978-1-60327-084-7_21 · Cited by 50
Tucholski, T., Knott, S. J., Chen, B., Pistono, P., Lin, Z., & Ge, Y. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04082 · Cited by 49
Phosphoproteomics: Searching for a needle in a haystack
Tichý, A., Šalovská, B., Řehulka, P., Klimentová, J., Vávrová, J., Stulík, J., & Hernychová, L. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.07.018 · Cited by 58
“Syka and co-workers [72] invented ETD, which induces fragmentation of peptides by transferring electrons to them.”
BackgroundWongkongkathep, P., Li, H., Zhang, X., Loo, R. R. O., Julian, R. R., & Loo, J. A. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2015.07.008 · Cited by 53
“Electron transfer dissociation (ETD) [19] has also shown some capabilities for disulfide bond cleavage [20, 21].”
BackgroundInfluentialTu, C., Li, J., Young, R. F., Page, B. J., Engler, F. A., Halfon, M. S., Canty, J. M., & Qu, J. (2011) · Analytical Chemistry · doi:10.1021/ac200376m · Cited by 49
Yang, C., Zhong, X., & Li, L. (2014) · Electrophoresis · doi:10.1002/elps.201400017 · Cited by 50
Song, E., & Mechref, Y. S. (2013) · Journal of Proteome Research · doi:10.1021/pr400101t · Cited by 51
Baliban, R. C., DiMaggio, P. A., Plazas-Mayorca, M. D., Young, N. L., Garcia, B. A., & Floudas, C. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900487-mcp200 · Cited by 54
“This process induces large amounts of backbone cleavage to yield c-ions and z -ions (32, 35) that are analogous to the b-ions”
BackgroundCannon, J. R., Holden, D. D., & Brodbelt, J. S. (2014) · Analytical Chemistry · doi:10.1021/ac5036082 · Cited by 46
Chouinard, C. D., Nagy, G., Webb, I., Shi, T., Baker, E. S., Prost, S. A., Liu, T., Ibrahim, Y., & Smith, R. D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02397 · Cited by 49
Mass Spectrometry: m/z 1983–2008
Zhou, M., & Veenstra, T. D. (2008) · BioTechniques · doi:10.2144/000112791 · Cited by 61
Gardner, M. W., Smith, S. I., Ledvina, A. R., Madsen, J. A., Coon, J. J., Schwartz, J. C., Stafford, G. C., & Brodbelt, J. S. (2009) · Analytical Chemistry · doi:10.1021/ac901313m · Cited by 54
Self-citationCobb, J. S., Easterling, M. L., & Agar, J. N. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.02.009 · Cited by 46
“Methods of protein fragmentation include CAD in a multipole [22], sustained off-resonance irradiation (SORI)-CAD [23], infrared multiphoton dissociation (IRMPD) [24], ECD [25], electron-transfer dissociation (ETD) [ 26 ], and the in-source fragmentation methods of prefolding dissociation (PFD) [27], nozzle-skimmer dis…”
MethodChemical and Pathway Proteomics
Kruse, U., Bantscheff, M., Drewes, G., & Hopf, C. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r800006-mcp200 · Cited by 56
Phosphoproteomics for the discovery of kinases as cancer biomarkers and drug targets
Yu, L., Issaq, H. J., & Veenstra, T. D. (2007) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.200700102 · Cited by 56
Backbone and side-chain specific dissociations of z ions from non-tryptic peptides
Chung, T. W., & Tureček, F. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.02.018 · Cited by 48
Neuhaus, J., Schiffer, E., von Wilcke, P., Bauer, H. W., Leung, H. Y., Siwy, J., Ulrici, W., Paasch, U., Horn, L., & Stolzenburg, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067514 · Cited by 52
“Tandem mass spectrometry [12-14] identified 141 native seminal peptides representing 47 different parental proteins (Table S3).”
BackgroundBetter score function for peptide identification with ETD MS/MS spectra
Liu, X., Shan, B., Xin, L., & Ma, B. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-s1-s4 · Cited by 48
“Recently, more fragmentation mechanisms such as infrared multiphoton dissociation (IRMPD) [19], electron capture dissociation (ECD) [20], and electron transfer dissociation (ETD) [21] have been developed.”
BackgroundAmon, S., Trelle, M. B., Jensen, O. N., & Jørgensen, T. J. D. (2012) · Analytical Chemistry · doi:10.1021/ac300268r · Cited by 49
Theisen, A., Black, R., Corinti, D., Brown, J. M., Bellina, B., & Barran, P. E. (2018) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-018-1992-0 · Cited by 53
“Electron-transfer dissociation (ETD) is also used for protein structure analysis although some of the caveats for ECD also apply [34].”
MethodMethods for Enrichment and Assignment of N-Acetylglucosamine Modification Sites
Maynard, J. C., & Chalkley, R. J. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r120.002206 · Cited by 49
Bodenmiller, B., & Aebersold, R. H. (2010) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(10)70013-6 · Cited by 52
Ropartz, D., Lemoine, J., Giuliani, A., Bittebière, Y., Enjalbert, Q., Antoine, R., Dugourd, P., Ralet, M., & Rogniaux, H. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.11.018 · Cited by 47
Taking aim at shotgun phosphoproteomics
Hoffert, J. D., & Knepper, M. A. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.11.023 · Cited by 47
“Combining this technique with “top-down” MS analysis of intact proteins has the potential to expand the capabilities of this method [5-7].”
MethodHigh‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics
Mohr, J., Swart, R., Samonig, M., Böhm, G., & Huber, C. G. (2010) · PROTEOMICS · doi:10.1002/pmic.201000341 · Cited by 46
“been pushed forward in the past years by the development of protein fragmentation methods based on CID [13], infrared multiphoton dissociation [14], electron-capture dissociation [15, 16], and electron-transfer dissociation [17] as well as by gas phase chemistry enabling charge-state manipulation of multiply charged p…”
MethodMass spectrometry-based proteomics and peptidomics for systems biology and biomarker discovery
Cunningham, R., Ma, D., & Li, L. (2012) · Frontiers in Biology · doi:10.1007/s11515-012-1218-y · Cited by 51
“ECD requires the ion of interest to be in contact with near-thermal electrons and for the electron capture event to occur on the millisecond time scale, but the time scale is inadequate for electron trapping in Paul traps or quadrupoles in the majority of mass spectrometers (Syka et al., 2004).”
BackgroundDisulfide bond cleavage in TEMPO‐free radical initiated peptide sequencing mass spectrometry
Lee, M., Lee, Y.-J., Kang, M., Park, H., Seong, Y.-M., Sung, B. J., Moon, B., & Oh, H. B. (2011) · Journal of Mass Spectrometry · doi:10.1002/jms.1955 · Cited by 53
Peng, I. X., Loo, R. R. O., Margalith, E., Little, M. W., & Loo, J. A. (2010) · The Analyst · doi:10.1039/b923303b · Cited by 47
Yang, C., Park, A. C., Davis, N. A., Russell, J. D., Kim, B., Brand, D. D., Lawrence, M. J., Ge, Y., Westphall, M. S., Coon, J. J., et al. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.406850 · Cited by 47
“The hybrid orbitrap mass spectrometer permitted the use of several dissociation techniques; resonant excitation collisionactivated dissociation, beam-type collision-activated dissociation (higher energy collisional dissociation (HCD)), and ETD (38, 39).”
MethodSelf-citationChen, J., Cui, W., Giblin, D. E., & Gross, M. L. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0403-1 · Cited by 47
“With recently developed MS/MS techniques of electron-transfer dissociation (ETD) [31] and electron-capture dissociation (ECD) [32], the top-down approach has become more efficient and gives better sequence coverage and more tolerance towards labile PTMs.”
Resonance methods in quadrupole ion traps
Snyder, D. T., Peng, W., & Cooks, R. G. (2016) · Chemical Physics Letters · doi:10.1016/j.cplett.2016.11.011 · Cited by 50
Mass spectrometry for serine ADP-ribosylation? Think o-glycosylation!
Bonfiglio, J. J., Colby, T., & Matić, I. (2017) · Nucleic Acids Research · doi:10.1093/nar/gkx446 · Cited by 49
“In contrast, fragmentation techniques that specifically target the bonds in the peptide backbone, like electroncapture dissociation (ECD) (27) or electron-transfer dissociation (ETD) (28), leave the ADP-ribose intact and yield spectra that are rich in information about the peptide sequence as well as the modification’…”
BackgroundInfluential
Metadata
- Authors
- Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F.
- Affiliations
- University of Virginia (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2004-06-21
- Volume
- 101
- Issue
- 26
- Pages
- 9528-9533
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC470779
- OpenAlex
- W2131741443
- Cited by
- 2,370
- References
- 54
- Citations by year
- 2026: 31 · 2025: 38 · 2024: 53 · 2023: 50 · 2022: 56 · 2021: 71 · 2020: 79 · 2019: 85 · 2018: 93 · 2017: 107 · 2016: 118 · 2015: 151 · 2014: 153 · 2013: 169 · 2012: 164
- FWCI
- 36.00
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (0209793)
- National Institutes of Health (AI33993)
- National Institute of General Medical Sciences (GM37537, R01GM037537)
- National Institute of Allergy and Infectious Diseases (R37AI033993, R01AI033993, AI-33993)
- National Center for Research Resources (RR 018688, F32RR018688)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Keywords
- electron transfer dissociation, peptide sequence analysis, linear ion trap, radio frequency quadrupole, tandem mass spectrometry, electron capture dissociation, phosphopeptides, protein sequence analysis
- MeSH terms
- Amino Acid Sequence, Anions, Anthracenes, Chromatography, High Pressure Liquid, Electron Transport, Electrons, Molecular Sequence Data, Peptides, Phosphoproteins, Mass Spectrometry, Sequence Analysis, Protein
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.