Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Peptide sequence analysis using a combination of gas-phase ion/ion chemistry and tandem mass spectrometry (MS/MS) is demonstrated. Singly charged anthracene anions transfer an electron to multiply protonated peptides in a radio frequency quadrupole linear ion trap (QLT) and induce fragmentation of the peptide backbone along pathways that are analogous to those observed in electron capture dissociation. Modifications to the QLT that enable this ion/ion chemistry are presented, and automated acquisition of high-quality, single-scan electron transfer dissociation MS/MS spectra of phosphopeptides separated by nanoflow HPLC is described.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electron capture dissociation (ECD) [114] and electron transfer dissociation (ETD) [115], on the other hand, are nonergodic techniques for protein fragmentation.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [115]
Citations
Cites
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Proteomic analysis of post-translational modifications
Mann, M., & Jensen, O. N. (2003) · Nature Biotechnology · doi:10.1038/nbt0303-255 · Cited by 2,134
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Phosphoproteome analysis by mass spectrometry and its application to Saccharomyces cerevisiae
Ficarro, S. B., McCleland, M. L., Stukenberg, P. T., Burke, D. J., Ross, M. M., Shabanowitz, J., Hunt, D. F., & White, F. M. (2002) · Nature Biotechnology · doi:10.1038/nbt0302-301 · Cited by 1,636
Self-citationElectron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
A two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Self-citationZubarev, R. A., Kruger, N. A., Fridriksson, E. K., Lewis, M. A., Horn, D. M., Carpenter, B. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja981948k · Cited by 557
Reactions of polypeptide ions with electrons in the gas phase
Zubarev, R. A. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10042 · Cited by 431
Mirgorodskaya, E., Roepstorff, P., & Zubarev, R. A. (1999) · Analytical Chemistry · doi:10.1021/ac990578v · Cited by 381
Probability-Based Validation of Protein Identifications Using a Modified SEQUEST Algorithm
MacCoss, M. J., Wu, C. C., & Yates, J. R. (2002) · Analytical Chemistry · doi:10.1021/ac025826t · Cited by 377
Kelleher, N. L., Zubarev, R. A., Bush, K., Furie, B., Furie, B. C., McLafferty, F. W., & Walsh, C. T. (1999) · Analytical Chemistry · doi:10.1021/ac990684x · Cited by 368
Stensballe, A., Andersen, S., & Jensen, O. N. (2001) · PROTEOMICS · doi:10.1002/1615-9861(200102)1:2<207::aid-prot207>3.0.co;2-3 · Cited by 362
Håkansson, K., Cooper, H. J., Emmett, M. R., Costello, C. E., Marshall, A. G., & Nilsson, C. L. (2001) · Analytical Chemistry · doi:10.1021/ac0103470 · Cited by 359
Ge, Y., Lawhorn, B. G., ElNaggar, M., Strauss, E., Park, J.-H., Begley, T. P., & McLafferty, F. W. (2002) · Journal of the American Chemical Society · doi:10.1021/ja011335z · Cited by 353
Phosphopeptide/Phosphoprotein Mapping by Electron Capture Dissociation Mass Spectrometry
Shi, S. D.-H., Hemling, M. E., Carr, S. A., Horn, D. M., Lindh, I., & McLafferty, F. W. (2001) · Analytical Chemistry · doi:10.1021/ac000703z · Cited by 316
Metabotropic glutamate receptors: novel targets for pain relief
Neugebauer, V. (2001) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.1.2.207 · Cited by 298
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Pulsed positive negative ion chemical ionization mass spectrometry
Hunt, D. F., Stafford, G. C., Crow, F. W., & Russell, J. W. (1976) · Analytical Chemistry · doi:10.1021/ac50008a014 · Cited by 279
Self-citationMartin, S. E., Shabanowitz, J., Hunt, D. F., & Marto, J. A. (2000) · Analytical Chemistry · doi:10.1021/ac000497v · Cited by 276
Self-citationSze, S. K., Ge, Y., Oh, H., & McLafferty, F. W. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.251691898 · Cited by 250
Zubarev, R. A., Haselmann, K. F., Budnik, B., Kjeldsen, F., & Jensen, F. (2002) · European Journal of Mass Spectrometry · doi:10.1255/ejms.517 · Cited by 248
Håkansson, K., Chalmers, M. J., Quinn, J. P., McFarland, M. A., Hendrickson, C. L., & Marshall, A. G. (2003) · Analytical Chemistry · doi:10.1021/ac030015q · Cited by 245
McLafferty, F. W., Horn, D. M., Breuker, K., Ge, Y., Lewis, M. A., Cerda, B., Zubarev, R. A., & Carpenter, B. K. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00223-3 · Cited by 243
Ion/ion chemistry of high-mass multiply charged ions
McLuckey, S. A., & Stephenson, J. L. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:6<369::aid-mas1>3.0.co;2-j · Cited by 233
Electron capture negative ion chemical ionization mass spectrometry
Hunt, D. F., & Crow, F. W. (1978) · Analytical Chemistry · doi:10.1021/ac50035a017 · Cited by 202
Self-citationTsybin, Y. O., Witt, M., Baykut, G., Kjeldsen, F., & Håkansson, P. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1118 · Cited by 141
Stephenson, J. L., & McLuckey, S. A. (1998) · Analytical Chemistry · doi:10.1021/ac9802832 · Cited by 141
Tsybin, Y. O., Håkansson, P., Budnik, B., Haselmann, K. F., Kjeldsen, F., Gorshkov, M. V., & Zubarev, R. A. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.448 · Cited by 123
Ion Parking during Ion/Ion Reactions in Electrodynamic Ion Traps
McLuckey, S. A., Reid, G. E., & Wells, J. M. (2002) · Analytical Chemistry · doi:10.1021/ac0109671 · Cited by 115
Haselmann, K. F., Budnik, B., Olsen, J. V., Nielsen, M. L., Reis, C. A., Clausen, H., Johnsen, A. H., & Zubarev, R. A. (2001) · Analytical Chemistry · doi:10.1021/ac0015523 · Cited by 107
Chrisman, P. A., & McLuckey, S. A. (2002) · Journal of Proteome Research · doi:10.1021/pr025561z · Cited by 99
Budnik, B., Haselmann, K. F., El’kin, Y. N., Иванович, Г. В., & Zubarev, R. A. (2003) · Analytical Chemistry · doi:10.1021/ac034477f · Cited by 95
Gas-Phase Concentration, Purification, and Identification of Whole Proteins from Complex Mixtures
Reid, G. E., Shang, H., Hogan, J. M., Lee, G. U., & McLuckey, S. A. (2002) · Journal of the American Chemical Society · doi:10.1021/ja025966k · Cited by 94
Håkansson, K., Hudgins, R. R., Marshall, A. G., & O’Hair, R. A. J. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00708-0 · Cited by 92
McLuckey, S. A., Stephenson, J. L., & Asano, K. G. (1998) · Analytical Chemistry · doi:10.1021/ac9710137 · Cited by 88
Stephenson, J. L., & McLuckey, S. A. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04510-7 · Cited by 84
Ge, Y., ElNaggar, M., Sze, S. K., Oh, H. B., Begley, T. P., McLafferty, F. W., Boshoff, H., & Barry, C. E. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00913-3 · Cited by 79
Taniguchi, N., Ekuni, A., Ko, J. H., Miyoshi, E., Ikeda, Y., Ihara, Y., Nishikawa, A., Honke, K., & Takahashi, M. (2001) · PROTEOMICS · doi:10.1002/1615-9861(200102)1:2<239::aid-prot239>3.0.co;2-k · Cited by 79
A New Approach for Plant Proteomics
Zabrouskov, V., Giacomelli, L., van Wijk, K. J., & McLafferty, F. W. (2003) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300069-mcp200 · Cited by 74
Håkansson, K., Emmett, M. R., Hendrickson, C. L., & Marshall, A. G. (2001) · Analytical Chemistry · doi:10.1021/ac010141z · Cited by 72
Charge state dependent collision‐induced dissociation of native and reduced porcine elastase
Hogan, J. M., & McLuckey, S. A. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.458 · Cited by 69
Amunugama, R., Hogan, J. M., Newton, K. A., & McLuckey, S. A. (2004) · Analytical Chemistry · doi:10.1021/ac034900k · Cited by 56
Mirgorodskaya, E. E., Hassan, H., Clausen, H., & Roepstorff, P. (2001) · Analytical Chemistry · doi:10.1021/ac001288d · Cited by 55
Engel, B. J., Pan, P., Reid, G. E., Wells, J. M., & McLuckey, S. A. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00562-6 · Cited by 55
Electron capture dissociation of multiply-charged oxygenated cations. A nonergodic process
Cerda, B. A., Horn, D. M., Breuker, K., Carpenter, B. K., & McLafferty, F. W. (1999) · European Journal of Mass Spectrometry · doi:10.1255/ejms.293 · Cited by 55
Detection of four oxidation sites in viral prolyl‐4‐hydroxylase by top‐down mass spectrometry
Ge, Y., Lawhorn, B. G., ElNaggar, M., Sze, S. K., Begley, T. P., & McLafferty, F. W. (2003) · Protein Science · doi:10.1110/ps.03244403 · Cited by 39
High Resolution Tandem Mass Spectrometry for Structural Biochemistry
Håkansson, K., Cooper, H., Hudgins, R. R., & Nilsson, C. L. (2003) · Current Organic Chemistry · doi:10.2174/1385272033486305 · Cited by 37
Hogan, J. M., Pitteri, S. J., & McLuckey, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac034410s · Cited by 37
Cooper, H. J., Case, M. A., McLendon, G. L., & Marshall, A. G. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021138f · Cited by 37
Charlebois, J. P., Patrie, S. M., & Kelleher, N. L. (2003) · Analytical Chemistry · doi:10.1021/ac020690k · Cited by 37
Improvement of electron capture efficiency by resonant excitation
Mormann, M., & Peter‐Katalinić, J. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1163 · Cited by 28
Affecting Proton Mobility in Activated Peptide and Whole Protein Ions via Lysine Guanidination
Pitteri, S. J., Reid, G. E., & McLuckey, S. A. (2003) · Journal of Proteome Research · doi:10.1021/pr034054u · Cited by 26
Fagerquist, C. K., Hudgins, R. R., Emmett, M. R., Håkansson, K., & Marshall, A. G. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00063-1 · Cited by 19
Emmett, M. R. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)01127-0 · Cited by 16
Fagerquist, C. K., Hudgins, R. R., Emmett, M. R., Håkansson, K., & Marshall, A. G. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00331-3 · Cited by 2
Cited by
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334
Mass Spectrometry and Protein Analysis
Domon, B., & Aebersold, R. (2006) · Science · doi:10.1126/science.1124619 · Cited by 2,181
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Cycling of O-linked β-N-acetylglucosamine on nucleocytoplasmic proteins
Hart, G. W., Housley, M. P., & Slawson, C. (2007) · Nature · doi:10.1038/nature05815 · Cited by 1,418
“Furthermore, when new mass-spectrometric methods — such as TMS-ECD (Fourier transform mass spectrometry with electron-capture dissociation) or ETD (ion-trap mass spectrometry with electron-transfer dissociation”
MethodHart, G. W., Slawson, C., Ramirez-Correa, G., & Lagerlof, O. (2011) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-060608-102511 · Cited by 1,317
“A major breakthrough in the detection and site mapping of O-GlcNAc occurred first with the development of Fourier transform mass spectrometers capable of electron capture dissociation (ECD) (111) and subsequently with the development of ion-trap mass spectrometers, which could perform electron transfer dissociation ma…”
BackgroundInfluential
Metadata
- Authors
- Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F.
- Affiliations
- University of Virginia (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2004-06-21
- Volume
- 101
- Issue
- 26
- Pages
- 9528-9533
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC470779
- OpenAlex
- W2131741443
- Cited by
- 2,370
- References
- 54
- Citations by year
- 2026: 31 · 2025: 38 · 2024: 53 · 2023: 50 · 2022: 56 · 2021: 71 · 2020: 79 · 2019: 85 · 2018: 93 · 2017: 107 · 2016: 118 · 2015: 151 · 2014: 153 · 2013: 169 · 2012: 164
- FWCI
- 36.00
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (0209793)
- National Institutes of Health (AI33993)
- National Institute of General Medical Sciences (GM37537, R01GM037537)
- National Institute of Allergy and Infectious Diseases (R37AI033993, R01AI033993, AI-33993)
- National Center for Research Resources (RR 018688, F32RR018688)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Keywords
- electron transfer dissociation, peptide sequence analysis, linear ion trap, radio frequency quadrupole, tandem mass spectrometry, electron capture dissociation, phosphopeptides, protein sequence analysis
- MeSH terms
- Amino Acid Sequence, Anions, Anthracenes, Chromatography, High Pressure Liquid, Electron Transport, Electrons, Molecular Sequence Data, Peptides, Phosphoproteins, Mass Spectrometry, Sequence Analysis, Protein
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.