Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Peptide sequence analysis using a combination of gas-phase ion/ion chemistry and tandem mass spectrometry (MS/MS) is demonstrated. Singly charged anthracene anions transfer an electron to multiply protonated peptides in a radio frequency quadrupole linear ion trap (QLT) and induce fragmentation of the peptide backbone along pathways that are analogous to those observed in electron capture dissociation. Modifications to the QLT that enable this ion/ion chemistry are presented, and automated acquisition of high-quality, single-scan electron transfer dissociation MS/MS spectra of phosphopeptides separated by nanoflow HPLC is described.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electron capture dissociation (ECD) [114] and electron transfer dissociation (ETD) [115], on the other hand, are nonergodic techniques for protein fragmentation.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [115]
Citations
Cites
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Proteomic analysis of post-translational modifications
Mann, M., & Jensen, O. N. (2003) · Nature Biotechnology · doi:10.1038/nbt0303-255 · Cited by 2,134
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Phosphoproteome analysis by mass spectrometry and its application to Saccharomyces cerevisiae
Ficarro, S. B., McCleland, M. L., Stukenberg, P. T., Burke, D. J., Ross, M. M., Shabanowitz, J., Hunt, D. F., & White, F. M. (2002) · Nature Biotechnology · doi:10.1038/nbt0302-301 · Cited by 1,636
Self-citationElectron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
A two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Self-citationZubarev, R. A., Kruger, N. A., Fridriksson, E. K., Lewis, M. A., Horn, D. M., Carpenter, B. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja981948k · Cited by 557
Reactions of polypeptide ions with electrons in the gas phase
Zubarev, R. A. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10042 · Cited by 431
Mirgorodskaya, E., Roepstorff, P., & Zubarev, R. A. (1999) · Analytical Chemistry · doi:10.1021/ac990578v · Cited by 381
Probability-Based Validation of Protein Identifications Using a Modified SEQUEST Algorithm
MacCoss, M. J., Wu, C. C., & Yates, J. R. (2002) · Analytical Chemistry · doi:10.1021/ac025826t · Cited by 377
Cited by
Items 501–600 of 1,005
Covalent Modification of Gaseous Peptide Ions with N-Hydroxysuccinimide Ester Reagent Ions
Mentinova, M., & McLuckey, S. A. (2010) · Journal of the American Chemical Society · doi:10.1021/ja107286p · Cited by 65
Ly, T., & Julian, R. R. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.02.009 · Cited by 72
“Both electron capture dissociation (ECD) and electron transfer dissociation (ETD) are now conventional methods in proteomic analyses [2, 3].”
MethodGSK3- and PRMT-1–dependent modifications of desmoplakin control desmoplakin–cytoskeleton dynamics
Albrecht, L. V., Zhang, L., Shabanowitz, J., Purevjav, E., Towbin, J. A., Hunt, D. F., & Green, K. J. (2015) · The Journal of Cell Biology · doi:10.1083/jcb.201406020 · Cited by 70
“To address these challenges, we applied tandem mass spectrometry (MS/MS) using front-end electron transfer dissociation (FETD) to map DP phosphorylation at the putative GSK3 sites (Syka et al., 2004; Earley et al., 2013).”
Self-citationJones, J. W., Thompson, C. J., Carter, C. L., & Kane, M. A. (2015) · Journal of Mass Spectrometry · doi:10.1002/jms.3499 · Cited by 66
“A range of electron-based dissociation techniques, including electron-capture dissociation (ECD),([17]) hot ECD,([18]) electron-transfer dissociation,([19]) electrondetachment dissociation,([20]) electronic-excitation dissociation([21]) and electron-induced dissociation (EID),([22]) have been used to provide confident…”
Methods for combining peptide intensities to estimate relative protein abundance
Carrillo, B., Yanofsky, C. M., LaBoissière, S., Nadon, R., & Kearney, R. E. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp610 · Cited by 70
Kaplan, D. A., Hartmer, R., Speir, J. P., Stoermer, C., Gumerov, D. R., Easterling, M. L., Brekenfeld, A., Kim, T., Laukien, F. H., & Park, M. A. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3356 · Cited by 68
Mass Spectrometric Analysis of Histone Proteoforms
Yuan, Z.-F., Arnaudo, A. M., & Garcia, B. A. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-015959 · Cited by 64
“For example, collision induced dissociation (CID) produces b and y ions from the N-terminal and C-terminal parts, respectively, and electron transfer dissociation (ETD) and electron capture dissociation (ECD) produce c and z ions from the N-terminal and C-terminal parts, respectively (10, 11).”
BackgroundRecent developments in quantitative proteomics
Becker, C. H., & Bern, M. W. (2010) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2010.06.016 · Cited by 72
“A ignificant recent development has been the advent of electronransfer dissociation (ETD) for ion-trapmass spectrometers [23,24] nd electron capture dissociation (ECD) under high vacuum such s for FTMS instruments [25].”
BackgroundLiu, R., Xia, S., & Li, H. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21793 · Cited by 66
Post-acquisition ETD spectral processing for increased peptide identifications
Good, D. M., Wenger, C. D., McAlister, G. C., Bai, D. L., Hunt, D. F., & Coon, J. J. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.006 · Cited by 67
“In electron-transfer dissociation (ETD), the ability to produce ECD-like spectra was achieved within an ion trap mass spectrometer through reaction of analyte cations with radical anion molecules [2, 3].”
BackgroundSelf-citationTureček, F., Jones, J. W., Towle, T. R., Panja, S., Nielsen, S. B., Hvelplund, P., & Paizs, B. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8036367 · Cited by 67
Identification of membrane proteins by tandem mass spectrometry of protein ions
Carroll, J., Altman, M. C., Fearnley, I. M., & Walker, J. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706817104 · Cited by 65
Identification of CaMKII Phosphorylation Sites in Connexin43 by High-Resolution Mass Spectrometry
Huang, R. Y. ‐., Laing, J. G., Kanter, E. M., Berthoud, V. M., Bao, M., Rohrs, H. W., Townsend, R. R., & Yamada, K. A. (2010) · Journal of Proteome Research · doi:10.1021/pr1008702 · Cited by 64
Thompson, N., Rosati, S., Rose, R., & Heck, A. J. R. (2012) · Chemical Communications · doi:10.1039/c2cc36755f · Cited by 69
The application of MALDI TOF MS in biopharmaceutical research
Kafka, A. P., Kleffmann, T., Rades, T., & McDowell, A. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.010 · Cited by 76
Wada, Y., Tajiri, M., & Ohshima, S. (2010) · Journal of Proteome Research · doi:10.1021/pr900913k · Cited by 66
Systems-wide proteomic characterization of combinatorial post-translational modification patterns
Young, N. L., Plazas-Mayorca, M. D., & Garcia, B. A. (2010) · Expert Review of Proteomics · doi:10.1586/epr.09.100 · Cited by 72
Wolschin, F., & Weckwerth, W. (2005) · Plant Methods · doi:10.1186/1746-4811-1-9 · Cited by 64
“Another promising method is the analysis of peptide sequences by electron transfer dissociation [24] but this requires sophisticated modification of the mass spectrometer not yet widely available.”
MethodAdvancements in plant proteomics using quantitative mass spectrometry
Oeljeklaus, S., Meyer, H. E., & Warscheid, B. (2008) · Journal of Proteomics · doi:10.1016/j.jprot.2008.11.008 · Cited by 64
Takahashi, H., Shimabukuro, Y., Asakawa, D., Yamauchi, S., Sekiya, S., Iwamoto, S., Wada, M., & Tanaka, K. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00322 · Cited by 65
Háda, V., Bagdi, A., Bihari, Z., Timári, S. B., Fizil, Á., & Szántay, C. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2018.08.024 · Cited by 66
Mass spectrometry in nutrition: Understanding dietary health effects at the molecular level
Kussmann, M., Affolter, M., Nagy, K., Holst, B., & Fay, L. B. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20147 · Cited by 70
“…fragmentation complexity of peptides, a novel technique called electron-transfer dissociation (ETD) was introduced, which can be combined with conventional Paul traps (Syka et al., 2004; Hartmer & Lubeck, 2005) and hence by-passes the necessity of an investment into an expensive ECD-FT-ICR system.”
MethodWang, D., Baudys, J., Bundy, J. L., Solano, M. I., Keppel, T. R., & Barr, J. R. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03301 · Cited by 63
Advanced proteomic technologies for cancer biomarker discovery
Wong, S. C. C., Chan, C. M. L., Ma, B. B. Y., Lam, M. Y. Y., Choi, G. C. G., Au, T. C. C., Chan, A. S. K., & Chan, A. T. �. (2009) · Expert Review of Proteomics · doi:10.1586/epr.09.1 · Cited by 70
Peng, I. X., Shiea, J., Loo, R. R. O., & Loo, J. A. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3154 · Cited by 68
Roy, S., Davydova, M. P., Pal, R., Gilmore, K. M., Tolstikov, G. A., Vasilevsky, S. F., & Alabugin, I. V. (2011) · The Journal of Organic Chemistry · doi:10.1021/jo201259j · Cited by 66
Specific UV photodissociation of tyrosyl‐containing peptides in multistage mass spectrometry
Joly, L., Antoine, R., Broyer, M., Dugourd, P., & Lemoine, J. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1222 · Cited by 70
Enhanced Dissociation of Intact Proteins with High Capacity Electron Transfer Dissociation
Riley, N. M., Mullen, C., Weisbrod, C. R., Sharma, S., Senko, M. W., Zabrouskov, V., Westphall, M. S., Syka, J. E. P., & Coon, J. J. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1306-8 · Cited by 59
Self-citationDeciphering plant-microbe crosstalk through proteomics studies
Jain, A., Singh, H. B., & Das, S. (2020) · Microbiological Research · doi:10.1016/j.micres.2020.126590 · Cited by 64
Leurs, U., Mistarz, U. H., & Rand, K. D. (2015) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2015.03.012 · Cited by 65
N-glycoproteomics in plants: Perspectives and challenges
Song, W., Henquet, M., Mentink, R. A., van Dijk, A. D. J., Cordewener, J. H. G., Bosch, D., America, A. H. P., & van der Krol, A. R. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.05.007 · Cited by 63
“[84] Syka JEP, Coon JJ, Schroeder MJ, Shabanowitz J, Hunt DF.”
BackgroundPatriksson, A., Adams, C. M., Kjeldsen, F., Raber, J., van der Spoel, D., & Zubarev, R. A. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2005.11.018 · Cited by 67
Shotguns in the Front Line: Phosphoproteomics in Plants
Nakagami, H., Sugiyama, N., Ishihama, Y., & Shirasu, K. (2011) · Plant and Cell Physiology · doi:10.1093/pcp/pcr148 · Cited by 63
Precision genome editing: A small revolution for glycobiology
Steentoft, C., Bennett, E. P., Schjoldager, K. T.-B. G., Vakhrushev, S. Y., Wandall, H. H., & Clausen, H. (2014) · Glycobiology · doi:10.1093/glycob/cwu046 · Cited by 59
“…becoming addressable by improved mass spectrometry (MS) fragmentation strategies, particularly utilizing electron transfer dissociation (ETD) technology to enable sequencing of the protein backbone with minimal loss or fragmentation of the glycan entity (Syka et al. 2004; Hogan et al. 2005).”
BackgroundO-GlcNAc: A Sweetheart of the Cell Cycle and DNA Damage Response
Liu, C., & Li, J. (2018) · Frontiers in Endocrinology · doi:10.3389/fendo.2018.00415 · Cited by 64
“Mass Spectrometry (MS) Last three decades have witnessed significant strides in developing MS instruments, especially electron transfer dissociation (ETD) MS (47, 48) and higher energy collisional dissociation (HCD)MS (49).”
BackgroundThe Negative Mode Proteome with Activated Ion Negative Electron Transfer Dissociation (AI-NETD)
Riley, N. M., Rush, M. J. P., Rose, C. M., Richards, A., Kwiecien, N. W., Bailey, D. J., Hebert, A. S., Westphall, M. S., & Coon, J. J. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m115.049726 · Cited by 61
“mode analog of electron transfer dissociation (ETD) (26), pep-”
BackgroundSelf-citationAdvances in high‐resolution mass spectrometry techniques for analysis of high mass‐to‐charge ions
Lai, Y., & Wang, Y. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21790 · Cited by 64
Papanastasiou, D. K., Kounadis, D., Lekkas, A., Orfanopoulos, I., Mpozatzidis, A., Smyrnakis, A., Panagiotopoulos, E., Kosmopoulou, M., Reinhardt-Szyba, M., Fort, K. L., et al. (2022) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.2c00214 · Cited by 66
Role of Oxylipins in the Inflammatory-Related Diseases NAFLD, Obesity, and Type 2 Diabetes
Misheva, M., Johnson, J. S., & McCullagh, J. (2022) · Metabolites · doi:10.3390/metabo12121238 · Cited by 61
Differentiation of isomeric amino acid residues in proteins and peptides using mass spectrometry
Perez‐Hurtado, P., & O’Connor, P. B. (2012) · Mass Spectrometry Reviews · doi:10.1002/mas.20357 · Cited by 63
Kus, J. V., Kelly, J. F., Tessier, L., Harvey, H., Cvitkovitch, D. G., & Burrows, L. L. (2008) · Journal of Bacteriology · doi:10.1128/jb.01075-08 · Cited by 61
“ETD-MS involves a novel method of peptide fragmentation that cleaves the bond between the amide nitrogen and the alpha carbon of the peptide, while delicate posttranslational modifications, such as O-linked phosphorylation and glycosylation, remain unaltered (16, 29, 56, 63).”
MethodLutz, E., Wieser, H., & Koehler, P. (2012) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf204973u · Cited by 61
Introduction to Mass Spectrometry-Based Proteomics
Matthiesen, R., & Bunkenborg, J. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-392-3_1 · Cited by 70
Anderson, L. C., Karch, K. R., Ugrin, S. A., Coradin, M., English, A. M., Sidoli, S., Shabanowitz, J., Garcia, B. A., & Hunt, D. F. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o115.053843 · Cited by 60
“With the advent of electron transfer dissociation (ETD) and more efficient electron capture dissociation fragmentation methods, which are better suited for larger, more highly charged peptides (12, 13), several studies utilizing other endoproteases to generate longer peptides have emerged (14– 16).”
BackgroundSelf-citationPrecursor ion independent algorithm for top-down shotgun proteomics
Tsai, Y. S., Scherl, A., Shaw, J. L., MacKay, C. L., Shaffer, S. A., Langridge-Smith, P. R. R., & Goodlett, D. R. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.07.024 · Cited by 59
“Third, while ETD may be used on inexpensive ion traps, these mass analyzers do not offer the resolution required for interpretation of protein tandem mass spectra, and conversely ECD is mainly used in combination with expensive Fouriertransform ion cyclotron resonance (FT-ICR) mass analyzers that do provide this capab…”
MethodInfluentialQuantitative phosphoproteomics to characterize signaling networks
Rigbolt, K. T. G., & Blagoev, B. (2012) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2012.05.006 · Cited by 62
“[40] Syka JE, Coon JJ, Schroeder MJ, Shabanowitz J, Hunt DF.”
BackgroundXia, Y., & Cooks, R. G. (2010) · Analytical Chemistry · doi:10.1021/ac9028328 · Cited by 63
Lima, V. V., Spitler, K. M., Choi, H., Webb, R. C., & Tostes, R. C. (2012) · Clinical Science · doi:10.1042/cs20110638 · Cited by 68
Leib, R. D., Donald, W. A., Bush, M. F., O'Brie, J. T., & Williams, E. R. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0666607 · Cited by 63
Wang, H., Straubinger, R. M., Aletta, J. M., Cao, J., Duan, X., Yu, H., & Qu, J. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.11.008 · Cited by 59
“A recent study by Coon and coworkers suggested that the fragmentation efficiency and resulting sequence coverage by ETD is approximately proportional to the charge density (i.e., number of charges/number of residues) of the precursor peptide ions [28].”
BackgroundMethodInfluentialIdentification of mammalian cell lines using MALDI-TOF and LC-ESI-MS/MS mass spectrometry
Zhang, X., Scalf, M., Berggren, W. T., Westphall, M. S., & Smith, L. M. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.12.007 · Cited by 59
“several years, such as electron capture dissociation (ECD) [79 – 82] and electron-transfer dissociation (ETD) [83, 84], have significantly increased the ability of FT instruments to obtain high-quality fragmentation results.”
BackgroundQuantitative phosphoproteomics – an emerging key technology in signal‐transduction research
Schreiber, T. B., Mäusbacher, N., Breitkopf, S. B., Grundner‐Culemann, K., & Daub, H. (2008) · PROTEOMICS · doi:10.1002/pmic.200800132 · Cited by 60
“[31], which has been implemented on IT instruments and is commercially available with the HCTultra II (Bruker Daltonics) or the LTQOrbitrap XL ETD (Thermo Scientific).”
MethodZhang, L., & Reilly, J. P. (2008) · Journal of Proteome Research · doi:10.1021/pr800766f · Cited by 64
Advantages of Extended Bottom-Up Proteomics Using Sap9 for Analysis of Monoclonal Antibodies
Srzentić, K., Fornelli, L., Laskay, Ü. A., Monod, M., Beck, A., Ayoub, D., & Tsybin, Y. O. (2014) · Analytical Chemistry · doi:10.1021/ac502766n · Cited by 64
Insights into the study and origin of the citrullinome in rheumatoid arthritis
Fert‐Bober, J., Darrah, E., & Andrade, F. (2019) · Immunological Reviews · doi:10.1111/imr.12834 · Cited by 60
TUTORIAL: ION ACTIVATION IN TANDEM MASS SPECTROMETRY USING ULTRA‐HIGH RESOLUTION INSTRUMENTATION
Bayat, P., Lesage, D., & Cole, R. B. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21623 · Cited by 69
Sulfopeptide fragmentation in electron-capture and electron-transfer dissociation
Medzihradszky, K. F., Guan, S., Maltby, D. A., & Burlingame, A. L. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.06.002 · Cited by 59
“Electron-transfer dissociation [8, 9] was also employed to analyze synthetic phospho- and sulfopeptides.”
MethodThe Role of Excited Rydberg States in Electron Transfer Dissociation
Sobczyk, M. A., & Simons, J. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp0604701 · Cited by 62
Paxillin phosphorylation sites mapped by mass spectrometry
Webb, D. J., Schroeder, M. J., Brame, C. J., Whitmore, L. A., Shabanowitz, J., Hunt, D. F., & Horwitz, A. R. (2005) · Journal of Cell Science · doi:10.1242/jcs.02563 · Cited by 59
“ETD spectra were recorded on an in-lab modified LTQ mass spectrometer described in (Syka et al., 2004) with fluoranthene as the electron transfer reagent.”
MethodSelf-citationSoftware eyes for protein post‐translational modifications
Na, S., & Paek, E. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21425 · Cited by 61
Urinary Collagen Fragments Are Significantly Altered in Diabetes: A Link to Pathophysiology
Maahs, D. M., Siwy, J., Argilés, À., Černá, M., Delles, C., Dominiczak, A. F., Gayrard, N., Iphöfer, A., Jänsch, L., Jerums, G., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013051 · Cited by 63
“In order to identify the defined biomarkers, we applied MS/MS peptide sequencing using CE- or liquid chromatography (LC)MS/MS analysis including either collision-induced dissociation (CID) [8,54] or electron transfer dissociation (ETD) [38,55,56].”
MethodCook, S. L., Collin, O. L., & Jackson, G. P. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1598 · Cited by 62
“[28,29] Electron transfer dissociation (ETD) has been proven to work very effectively for small to medium size polycationic peptides.”
BackgroundCanon, F., Milosavljević, A. R., van der Rest, G., Réfrégiers, M., Nahon, L., Sarni‐Manchado, P., Cheynier, V., & Giuliani, A. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201304046 · Cited by 62
Peptide and protein quantification using iTRAQ with electron transfer dissociation
Phanstiel, D., Zhang, Y., Marto, J. A., & Coon, J. J. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.05.023 · Cited by 57
Self-citationIon–molecule reactions reveal facile radical migration in peptides
Moore, B. N., Blanksby, S. J., & Julian, R. R. (2009) · Chemical Communications · doi:10.1039/b907833a · Cited by 65
Leach, F. E., Riley, N. M., Westphall, M. S., Coon, J. J., & Amster, I. J. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1709-9 · Cited by 59
“The technique that satisfies these two requirements for anion tandem mass spectrometry is negative electron transfer dissociation (NETD) [29, 30], the negative-ion complement of electron transfer dissociation (ETD) [31].”
Self-citationRyan, D. J., Patterson, N. H., Putnam, N. E., Wilde, A. D., Weiss, A., Perry, W. J., Cassat, J. E., Skaar, E. P., Caprioli, R. M., & Spraggins, J. M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05889 · Cited by 56
Jebanathirajah, J. A., Pittman, J. L., Thomson, B. A., Budnik, B., Kaur, P., Rapé, M., Kirschner, M. W., Costello, C. E., & O’Connor, P. B. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.08.008 · Cited by 59
“Electron transfer dissociation (ETD) has been introduced in linear ion traps [6].”
BackgroundStrategies for proteomic analysis of non‐enzymatically glycated proteins
Priego‐Capote, F., & Sanchez, J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20187 · Cited by 58
Verification of automated peptide identifications from proteomic tandem mass spectra
Tabb, D. L., Friedman, D. B., & Ham, A. L. (2006) · Nature Protocols · doi:10.1038/nprot.2006.330 · Cited by 57
“The complexity of this chemistry is inherent to CID; more regular fragmentation may be possible by techniques such as electron-capture dissociation or electron-transfer dissociation 10 .”
BackgroundADP‐ribosylation of histones by ARTD1: An additional module of the histone code?
Hottiger, M. O. (2011) · FEBS Letters · doi:10.1016/j.febslet.2011.03.031 · Cited by 70
“ADP-riboses or phosphate groups) than conventional collision-induced dissociation (CID) mass spectrometry [26,39,40].”
BackgroundDe novo peptide sequencing by tandem MS using complementary CID and electron transfer dissociation
Bertsch, A., Leinenbach, A., Pervukhin, A., Lubeck, M., Hartmer, R., Baessmann, C., Elnakady, Y. A., Müller, R., Böcker, S., Huber, C. G., et al. (2009) · Electrophoresis · doi:10.1002/elps.200900332 · Cited by 63
Instant spectral assignment for advanced decision tree-driven mass spectrometry
Bailey, D. J., Rose, C. M., McAlister, G. C., Brumbaugh, J., Yu, P., Wenger, C. D., Westphall, M. S., Thomson, J. A., & Coon, J. J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1205292109 · Cited by 55
Self-citationUV photodissociation of trapped ions following ion mobility separation in a Q-ToF mass spectrometer
Bellina, B., Brown, J. M., Ujma, J., Murray, P., Giles, K., Morris, M. R., Compagnon, I., & Barran, P. E. (2014) · The Analyst · doi:10.1039/c4an01656d · Cited by 61
Azkargorta, M., Soria, J. M., Ojeda, C., Guzmán, F., Acera, A., Iloro, I., Suárez, T., & Elortza, F. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00179 · Cited by 62
Metallomics: An integrated biometal science
Ge, R., & Sun, H. (2009) · Science China Chemistry · doi:10.1007/s11426-009-0144-6 · Cited by 57
Huang, Y., Tseng, G. C., Yuan, S., Paša‐Tolić, L., Lipton, M. S. W., Smith, R. D., & Wysocki, V. H. (2007) · Journal of Proteome Research · doi:10.1021/pr070106u · Cited by 57
Kalli, A., & Håkansson, K. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.01.001 · Cited by 64
Ang, C., Binos, S., Knight, M. I., Moate, P. J., Cocks, B. G., & McDonagh, M. B. (2011) · Journal of Proteome Research · doi:10.1021/pr200516d · Cited by 65
Brinkmalm, A., & Brinkmalm, G. (2008) · Mass Spectrometry · doi:10.1002/9780470395813.ch3 · Cited by 62
Ge, R., & Shan, W. (2011) · Genomics Proteomics & Bioinformatics · doi:10.1016/s1672-0229(11)60015-6 · Cited by 58
Rauniyar, N., Stevens, S. M., Prókai-Tátrai, K., & Prókai, L. (2008) · Analytical Chemistry · doi:10.1021/ac802015m · Cited by 58
Tureček, F., Chung, T. W., Moss, C. L., Wyer, J. A., Ehlerding, A., Holm, A. I. S., Zettergren, H., Nielsen, S. B., Hvelplund, P., Chamot‐Rooke, J., et al. (2010) · Journal of the American Chemical Society · doi:10.1021/ja907808h · Cited by 60
Srikanth, R., Wilson, J. G., Bridgewater, J. D., Numbers, J. R., Lim, J., Olbris, M. R., Kettani, A., & Vachet, R. W. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.05.011 · Cited by 62
“ETD has a unique propensity to randomly cleave N–C bonds of the peptide backbone with relatively little regard to peptide length, amino acid°composition°and°PTMs°[36].”
BackgroundMayya, V., Rezaul, K., Cong, Y., & Han, D. K. M. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t400015-mcp200 · Cited by 56
“It has also been used to explore a novel tandem mass spectrometry approach termed electron transfer dissociation of peptides ( 27 ).”
MethodZhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55
Self-citationSong, Y., Song, Q., Liu, W., Li, J., & Tu, P. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.116982 · Cited by 55
Quantitative phosphoproteomic analysis of signaling network dynamics
White, F. M. (2008) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2008.06.006 · Cited by 55
“Although difficult, especially given the size of the proteins and number of modifications, this task should be feasible, as indicated in Figure 1, by combining lessons learned from top-down analysis of protein post-translational modifications (e.g. histone modifications [14]) with MS-based phosphoproteomics techniques…”
BackgroundCurrent algorithmic solutions for peptide-based proteomics data generation and identification
Hoopmann, M. R., & Moritz, R. L. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2012.10.013 · Cited by 60
“Electron transfer dissociation (ETD): This method is similar to ECD, but uses anions as vehicles for delivering electrons to multiply protonated ions trapped in the gas phase [64].”
MethodSubstrate Specificity of Mammalian N-Terminal α-Amino Methyltransferase NRMT
Petkowski, J. J., Tooley, C. E. S., Anderson, L. C., Shumilin, I. A., Balsbaugh, J. L., Shabanowitz, J., Hunt, D. F., Minor, W., & Macara, I. G. (2012) · Biochemistry · doi:10.1021/bi300278f · Cited by 55
Self-citationLC-MS for protein characterization: current capabilities and future trends
Chen, G., & Pramanik, B. N. (2008) · Expert Review of Proteomics · doi:10.1586/14789450.5.3.435 · Cited by 64
Sakakura, M., & Takayama, M. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.01.018 · Cited by 60
“Of the mass spectrometric dissociation methods used for identifying proteins, electron capture dissociation (ECD) [8] and electron-transfer dissociation (ETD) [9] coupled to ESI and in-source decay (ISD) coupled to MALDI [10] have been noted from the standpoint of specific cleavage at the N–”
InfluentialCompton, P. D., Strukl, J. V., Bai, D. L., Shabanowitz, J., & Hunt, D. F. (2012) · Analytical Chemistry · doi:10.1021/ac202807h · Cited by 54
Self-citationPhosphoproteomics with Activated Ion Electron Transfer Dissociation
Riley, N. M., Hebert, A. S., Dürnberger, G., Stanek, F., Mechtler, K., Westphall, M. S., & Coon, J. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00212 · Cited by 58
Self-citationSanders, J. D., Mullen, C., Watts, E., Holden, D. D., Syka, J. E. P., Schwartz, J. C., & Brodbelt, J. S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04026 · Cited by 57
Self-citationMass Spectrometry Data Analysis in Proteomics
Matthiesen, R. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-392-3 · Cited by 65
“The spectral complexity of CID/HCD-type MSMS is often increased by the remaining sugar residue but it has the advantage of being direct evidence of glycosylation and having a whole set of diagnostic oxonium fragment ions that can be used for targeted analysis.”
MethodInfluentialProteomic approaches to the analysis of multiprotein signaling complexes
Yang, W., Steen, H., & Freeman, M. R. (2008) · PROTEOMICS · doi:10.1002/pmic.200700650 · Cited by 62
“However, to date, this type of fragmentation is almost exclusively available in combination with FT-ICR [163, 167], the most expensive type of MS instrumentation.”
BackgroundMethodInfluentialUtility of mass spectrometry for proteome ana lysis: part I. Conceptual and experimental approaches
Ahmed, F. E. (2008) · Expert Review of Proteomics · doi:10.1586/14789450.5.6.841 · Cited by 55
Serra, A., Hemu, X., Nguyen, G. K. T., Nguyen, N. T. K., Sze, S. K., & Tam, J. P. (2016) · Scientific Reports · doi:10.1038/srep23005 · Cited by 57
Colzani, M., Aldini, G., & Carini, M. (2013) · Journal of Proteomics · doi:10.1016/j.jprot.2013.03.030 · Cited by 59
“in 2004 [35], also preserves labile PTMs, allowing straightforward identification of the peptide sequence and the site of modification.”
Background
Metadata
- Authors
- Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F.
- Affiliations
- University of Virginia (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2004-06-21
- Volume
- 101
- Issue
- 26
- Pages
- 9528-9533
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC470779
- OpenAlex
- W2131741443
- Cited by
- 2,370
- References
- 54
- Citations by year
- 2026: 31 · 2025: 38 · 2024: 53 · 2023: 50 · 2022: 56 · 2021: 71 · 2020: 79 · 2019: 85 · 2018: 93 · 2017: 107 · 2016: 118 · 2015: 151 · 2014: 153 · 2013: 169 · 2012: 164
- FWCI
- 36.00
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (0209793)
- National Institutes of Health (AI33993)
- National Institute of General Medical Sciences (GM37537, R01GM037537)
- National Institute of Allergy and Infectious Diseases (R37AI033993, R01AI033993, AI-33993)
- National Center for Research Resources (RR 018688, F32RR018688)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Keywords
- electron transfer dissociation, peptide sequence analysis, linear ion trap, radio frequency quadrupole, tandem mass spectrometry, electron capture dissociation, phosphopeptides, protein sequence analysis
- MeSH terms
- Amino Acid Sequence, Anions, Anthracenes, Chromatography, High Pressure Liquid, Electron Transport, Electrons, Molecular Sequence Data, Peptides, Phosphoproteins, Mass Spectrometry, Sequence Analysis, Protein
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.