The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A rare-cell detector for cancer
Open accessAbstract
Although a reliable method for detection of cancer cells in blood would be an important tool for diagnosis and monitoring of solid tumors in early stages, current technologies cannot reliably detect the extremely low concentrations of these rare cells. The preferred method of detection, automated digital microscopy (ADM), is too slow to scan the large substrate areas. Here we report an approach that uses fiber-optic array scanning technology (FAST), which applies laser-printing techniques to the rare-cell detection problem. With FAST cytometry, laser-printing optics are used to excite 300,000 cells per sec, and emission is collected in an extremely wide field of view, enabling a 500-fold speed-up over ADM with comparable sensitivity and superior specificity. The combination of FAST enrichment and ADM imaging has the performance required for reliable detection of early-stage cancer in blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection and characterization of carcinoma cells in the blood
Racila, E., Euhus, D., Weiss, A. J., Rao, C., McConnell, J., Terstappen, L. W. M. M., & Uhr, J. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4589 · Cited by 712
Schmidt-Kittler, O., Ragg, T., Daskalakis, A., Granzow, M., Ahr, A., Blankenstein, T. J. F., Kaufmann, M., Diebold, J., Arnholdt, H., Müller, P., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1331931100 · Cited by 631
Quantitation of cell shedding into efferent blood of mammary adenocarcinoma.
Butler, T. P., & Gullino, P. M. (1975) · PubMed · Cited by 528
Combined transcriptome and genome analysis of single micrometastatic cells
Klein, C. A., Seidl, S., Petat-Dutter, K., Offner, S., Geigl, J. B., Schmidt-Kittler, O., Wendler, N., Passlick, B., Huber, R. M., Schlimok, G., et al. (2002) · Nature Biotechnology · doi:10.1038/nbt0402-387 · Cited by 303
Witzig, T. E., Bossy, B., Kimlinger, T. K., Roche, P. C., Ingle, J. N., Grant, C. S., Donohue, J. H., Suman, V. J., Harrington, D. S., de la Torre-Bueno, J., et al. (2002) · PubMed · Cited by 156
Immunomagnetic enrichment of disseminated epithelial tumor cells from peripheral blood by MACS.
Martin, V. M., Siewert, C., Scharl, A. J., Harms, T., Heinze, R., Ohl, S., Radbruch, A., Miltenyi, S., & Schmitz, J. (1998) · PubMed · Cited by 141
Bajaj, S., Welsh, J. B., Leif, R. C., & Price, J. H. (2000) · Cytometry · Cited by 53
Wong, I. H. N., Yeo, W., Chan, A. T., et al. (2001) · Cancer Letters · doi:10.1016/s0304-3835(00)00630-3 · Cited by 44
Cited by
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Isolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Detection, clinical relevance and specific biological properties of disseminating tumour cells
Pantel, K., Brakenhoff, R. H., & Brandt, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2375 · Cited by 1,118
Circulating tumor cells: approaches to isolation and characterization
Yu, M., Stott, S., Toner, M., Maheswaran, S., & Haber, D. A. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201010021 · Cited by 1,089
Ozkumur, E., Shah, A. M., Ciciliano, J. C., Emmink, B. L., Miyamoto, D. T., Brachtel, E., Yu, M., Chen, P.-I., Morgan, B., Trautwein, J., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005616 · Cited by 1,086
Circulating tumour cells in cancer patients: challenges and perspectives
Pantel, K., & Alix-Panabières, C. (2010) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2010.07.001 · Cited by 815
Microfluidic, marker-free isolation of circulating tumor cells from blood samples
Karabacak, N. M., Spuhler, P. S., Fachin, F., Lim, E. J., Pai, V., Ozkumur, E., Martel, J. M., Kojic, N., Smith, K., Chen, P.-I., et al. (2014) · Nature Protocols · doi:10.1038/nprot.2014.044 · Cited by 760
Miller, M. C., Doyle, G. V., & Terstappen, L. W. M. M. (2010) · Journal of Oncology · doi:10.1155/2010/617421 · Cited by 750
Blood-Based Analyses of Cancer: Circulating Tumor Cells and Circulating Tumor DNA
Haber, D. A., & Velculescu, V. E. (2014) · Cancer Discovery · doi:10.1158/2159-8290.cd-13-1014 · Cited by 694
Pantel, K., Alix-Panabières, C., & Riethdorf, S. (2009) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2009.44 · Cited by 643
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Three‐Dimensional Nanostructured Substrates toward Efficient Capture of Circulating Tumor Cells
Wang, S., Wang, H., Jiao, J., Chen, K., Owens, G. E., Kamei, K., Sun, J., Sherman, D. J., Behrenbruch, C. P., Wu, H., et al. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901668 · Cited by 511
Circulating tumor cell technologies
Ferreira, M. M., Ramani, V. C., & Jeffrey, S. S. (2016) · Molecular Oncology · doi:10.1016/j.molonc.2016.01.007 · Cited by 511
Circulating Tumor Cells and Circulating Tumor DNA
Alix-Panabières, C., Schwarzenbach, H., & Pantel, K. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-062310-094219 · Cited by 485
Moon, H.-S., Kwon, K., Kim, S.-I., Han, H., Sohn, J., Lee, S., & Jung, H.-I. (2011) · Lab on a Chip · doi:10.1039/c0lc00345j · Cited by 437
Gleghorn, J. P., Pratt, E. D., Denning, D., Liu, H., Bander, N. H., Tagawa, S. T., Nanus, D. M., Giannakakou, P. A., & Kirby, B. J. (2010) · Lab Chip · doi:10.1039/b917959c · Cited by 396
Microdevice for the isolation and enumeration of cancer cells from blood
Tan, S. J., Yobas, L., Lee, G. Y. H., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9305-9 · Cited by 362
Detecting Circulating Tumor Cells: Current Challenges and New Trends
Hong, B., & Zu, Y. (2013) · Theranostics · doi:10.7150/thno.5195 · Cited by 351
Zhang, N., Deng, Y., Tai, Q., Cheng, B., Zhao, L., Shen, Q., He, R., Hong, L., Liu, W., Guo, S., et al. (2012) · Advanced Materials · doi:10.1002/adma.201200155 · Cited by 330
High-throughput size-based rare cell enrichment using microscale vortices
Hur, S. C., Mach, A. J., & Di Carlo, D. (2011) · Biomicrofluidics · doi:10.1063/1.3576780 · Cited by 317
Circulating tumor cells: a window into cancer biology and metastasis
Maheswaran, S., & Haber, D. A. (2010) · Current Opinion in Genetics & Development · doi:10.1016/j.gde.2009.12.002 · Cited by 316
Review: Biological relevance of disseminated tumor cells in cancer patients
Riethdorf, S., Wikman, H., & Pantel, K. (2008) · International Journal of Cancer · doi:10.1002/ijc.23825 · Cited by 309
Double spiral microchannel for label-free tumor cell separation and enrichment
Sun, J., Li, M., Liu, C., Zhang, Y., Liu, D., Liu, W., Hu, G., & Jiang, X. (2012) · Lab on a Chip · doi:10.1039/c2lc40679a · Cited by 293
Circulating tumor cells (CTCs): Detection methods and their clinical relevance in breast cancer
Mostert, B., Sleijfer, S., Foekens, J. A., & Gratama, J. W. (2009) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2009.03.004 · Cited by 282
Deryugina, E. I., & Quigley, J. P. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0536-2 · Cited by 279
Galanzha, E. I., Shashkov, E. V., Spring, P. M., Suen, J. Y., & Zharov, V. P. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4900 · Cited by 259
Circulating Tumor Cells: Fluid Surrogates of Solid Tumors
Thiele, J.-A., Bethel, K., Králíčková, M., & Kuhn, P. (2017) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-052016-100256 · Cited by 107
Self-citationAdvances in Ultrahigh Throughput Hit Discovery with Tandem Mass Spectrometry Encoded Libraries
Mata, J. M., van der Nol, E., & Pomplun, S. J. (2023) · Journal of the American Chemical Society · doi:10.1021/jacs.3c04899 · Cited by 27
Metadata
- Authors
- Krivacic, R. T., Ladanyi, A., Curry, D. N., Hsieh, H. B., Kuhn, P., Bergsrud, D. E., Kepros, J. F., Barbera, T., Ho, M. Y., Chen, L. B., Lerner, R. A., & Bruce, R. H.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-07-12
- Volume
- 101
- Issue
- 29
- Pages
- 10501-10504
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2057306577
- Cited by
- 340
- References
- 8
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.