The DOI matches its Crossref record.
Chemical cytometry on a picoliter-scale integrated microfluidic chip
Open accessAbstract
An integrated microfluidic device has been fabricated for analyzing the chemical contents of a single cell (chemical cytometry). The device is designed to accomplish four different functions: ( i ) cell handling, ( ii ) metering and delivering of chemical reagents, ( iii ) cell lysis and chemical derivatization, and ( iv ) separating derivatized compounds and detecting them by laser-induced fluorescence. These functions are accomplished with only two valves, formed by multilayer soft lithography. A new kind of three-state valve and a picopipette are described; these elements are crucial for minimizing the reaction volume and ensuring optimal shape of the channel for electrophoresis injection. By using these valves, a reaction volume of ≈70 pl is achieved for the lysis and derivitization of the contents of a single Jurkat T cell (≈10 μm diameter). As a demonstration of the use of this integrated microfluidic device, electropherograms of amino acids from individual Jurkat T cells are recorded and compared with those collected from a multiple-cell homogenate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Stochastic protein expression in individual cells at the single molecule level
Cai, L., Friedman, N., & Xie, X. S. (2006) · Nature · doi:10.1038/nature04599 · Cited by 1,145
Single cell analysis: the new frontier in ‘omics’
Wang, D., & Bodovitz, S. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.03.002 · Cited by 673
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Applications of microfluidics in chemical biology
Weibel, D. B., & Whitesides, G. M. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.10.016 · Cited by 443
Mechanical properties of silicones for MEMS
Schneider, F., Fellner, T., Wilde, J., & Wallrabe, U. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/065008 · Cited by 435
Analysis of single mammalian cells on-chip
Sims, C. E., & Allbritton, N. L. (2007) · Lab on a Chip · doi:10.1039/b615235j · Cited by 400
Counting Low-Copy Number Proteins in a Single Cell
Huang, B., Wu, H., Bhaya, D., Grossman, A., Granier, S., Kobilka, B. K., & Zare, R. N. (2007) · Science · doi:10.1126/science.1133992 · Cited by 387
Self-citationKang, L., Chung, B. G., Langer, R., & Khademhosseini, A. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.10.003 · Cited by 325
Microfluidic Platforms for Single-Cell Analysis
Zare, R. N., & Kim, S. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105238 · Cited by 318
Self-citationSingle Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Overview of single-cell analyses: microdevices and applications
Lindström, S., & Andersson-Svahn, H. (2010) · Lab on a Chip · doi:10.1039/c0lc00150c · Cited by 260
Metadata
- Authors
- Wu, H., Wheeler, A., & Zare, R. N.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-08-24
- Volume
- 101
- Issue
- 35
- Pages
- 12809-12813
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2035059163
- Cited by
- 241
- References
- 0
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.