The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Mechanotransduction and strain amplification in osteocyte cell processes
Open accessAbstract
A paradox in bone tissue is that tissue-level strains due to animal and human locomotion are too small to initiate intracellular chemical responses directly. A model recently was proposed to resolve this paradox, which predicts that the fluid flow through the pericellular matrix in the lacunar-canalicular porosity due to mechanical loading can induce strains in the actin filament bundles of the cytoskeleton that are more than an order of magnitude larger than tissue level strains. In this study, we greatly refine this model by using the latest ultrastructural data for the cell process cytoskeleton, the tethering elements that attach the process to the canalicular wall and their finite flexural rigidity EI. We construct a much more realistic 3D model for the osteocyte process and then use large-deformation “elastica” theory for finite EI to predict the deformed shape of the tethering elements and the hoop strain on the central actin bundle. Our model predicts a cell process that is 3 times stiffer than in a previous study but hoop strain of >0.5% for tissue-level strains of >1,000 microstrain at 1 Hz and >250 microstrain at frequencies >10 Hz. We propose that this strain-amplification model provides a more likely hypothesis for the excitation of osteocytes than the previously proposed fluid-shear hypothesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regulation of bone formation by applied dynamic loads.
Rubin, C. T., & Lanyon, L. E. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00012 · Cited by 1,558
A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses
Weinbaum, S., Cowin, S. C., & Zeng, Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90010-8 · Cited by 1,277
Self-citationMooseker, M. S., & Tilney, L. G. (1975) · The Journal of cell biology · doi:10.1083/jcb.67.3.725 · Cited by 622
Mechanotransduction and flow across the endothelial glycocalyx
Weinbaum, S., Zhang, X., Han, Y., Vink, H., & Cowin, S. C. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1332808100 · Cited by 579
Self-citationChondrocyte deformation and local tissue strain in articular cartilage: A confocal microscopy study
Guilak, F., Ratcliffe, A., & Mow, V. C. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130315 · Cited by 475
Mechanotransduction in bone: osteoblasts are more responsive to fluid forces than mechanical strain
Owan, I., Burr, D. B., Turner, C. H., Qiu, J., Tu, Y., Onyia, J. E., & Duncan, R. L. (1997) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1997.273.3.c810 · Cited by 467
You, L., Cowin, S. C., Schaffler, M. B., & Weinbaum, S. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00107-5 · Cited by 418
Self-citationFritton, S. P., J. McLeod, K., & Rubin, C. T. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00210-9 · Cited by 401
You, J., Yellowley, C. E., Donahue, H. J., Zhang, Y., Chen, Q., & Jacobs, C. R. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1287161 · Cited by 357
Ultrastructure of the osteocyte process and its pericellular matrix
You, L., Weinbaum, S., Cowin, S. C., & Schaffler, M. B. (2004) · The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology · doi:10.1002/ar.a.20050 · Cited by 326
Self-citationEffect of flow on prostaglandin E2 and inositol trisphosphate levels in osteoblasts
Reich, K. M., & Frangos, J. A. (1991) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1991.261.3.c428 · Cited by 255
Induction of NO and prostaglandin E2in osteoblasts by wall-shear stress but not mechanical strain
Smalt, R., Mitchell, F. T., Howard, R. L., & Chambers, T. J. (1997) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1997.273.4.e751 · Cited by 220
Michel, C. (1997) · Experimental Physiology · doi:10.1113/expphysiol.1997.sp004000 · Cited by 218
Tanaka-Kamioka, K., Kamioka, H., Ris, H., & Lim, S.-S. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.10.1555 · Cited by 203
Volkmann, N., DeRosier, D., Matsudaira, P., & Hanein, D. (2001) · The Journal of Cell Biology · doi:10.1083/jcb.153.5.947 · Cited by 170
Effects of repetitive motion on human fibroblasts
Almekinders, L. C., Banes, A. J., & Ballenger, C. A. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199305000-00012 · Cited by 155
Delineating bone's interstitial fluid pathway in vivo
Wang, L., Ciani, C., Doty, S. B., & Fritton, S. P. (2003) · Bone · doi:10.1016/j.bone.2003.11.022 · Cited by 132
A fiber matrix model for fluid flow and streaming potentials in the canaliculi of an osteon
Zeng, Y., Cowin, S. C., & Weinbaum, S. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368235 · Cited by 129
Self-citationWeinbaum, S. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.134 · Cited by 128
Self-citationActin in the inner ear: the remarkable structure of the stereocilium
DeRosier, D. J., Tilney, L. G., & Egelman, E. H. (1980) · Nature · doi:10.1038/287291a0 · Cited by 108
Reilly, G. C., Haut, T. R., Yellowley, C. E., Donahue, H. J., & Jacobs, C. R. (2003) · Biorheology · doi:10.1177/0006355x2003040006005 · Cited by 106
Jiang, J. X., & Cherian, P. P. (2003) · Cell Communication & Adhesion · doi:10.1080/cac.10.4-6.259.264 · Cited by 98
Weinbaum, S., Guo, P., & You, L. (2001) · Biorheology · doi:10.1177/0006355x2001038002003017 · Cited by 72
Self-citationMixing Mechanisms and Net Solute Transport in Bone
Tate, M. L. K. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1397788 · Cited by 25
Cited by
Bonewald, L. F. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.320 · Cited by 2,287
Bone Quality — The Material and Structural Basis of Bone Strength and Fragility
Seeman, E., & Delmas, P. D. (2006) · New England Journal of Medicine · doi:10.1056/nejmra053077 · Cited by 2,080
Osteocytes, mechanosensing and Wnt signaling
Bonewald, L. F., & Johnson, M. L. (2008) · Bone · doi:10.1016/j.bone.2007.12.224 · Cited by 1,076
“Several research groups have developed both analytical and numerical models in an attempt to predict fluid flow derived shear stresses in bone (124)(123)(122) (110)(44)(5).”
BackgroundSkeletal remodeling in health and disease
Zaidi, M. (2007) · Nature Medicine · doi:10.1038/nm1593 · Cited by 1,069
The Osteocyte: An Endocrine Cell … and More
Dallas, S. L., Prideaux, M., & Bonewald, L. F. (2013) · Endocrine Reviews · doi:10.1210/er.2012-1026 · Cited by 1,042
Metadata
- Authors
- Han, Y., Cowin, S. C., Schaffler, M. B., & Weinbaum, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-11-11
- Volume
- 101
- Issue
- 47
- Pages
- 16689-16694
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2093930926
- Cited by
- 496
- References
- 24
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.