Macromolecular-scale resolution in biological fluorescence microscopy
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
We demonstrate far-field fluorescence microscopy with a focal-plane resolution of 15–20 nm in biological samples. The 10- to 12-fold multilateral increase in resolution below the diffraction barrier has been enabled by the elimination of molecular triplet state excitation as a major source of photobleaching of a number of dyes in stimulated emission depletion microscopy. Allowing for relaxation of the triplet state between subsequent excitation–depletion cycles yields an up to 30-fold increase in total fluorescence signal as compared with reported stimulated emission depletion illumination schemes. Moreover, it enables the reduction of the effective focal spot area by up to ≈140-fold below that given by diffraction. Triplet-state relaxation can be realized either by reducing the repetition rate of pulsed lasers or by increasing the scanning speed such that the build-up of the triplet state is effectively prevented. This resolution in immunofluorescence imaging is evidenced by revealing nanoscale protein patterns on endosomes, the punctuated structures of intermediate filaments in neurons, and nuclear protein speckles in mammalian cells with conventional optics. The reported performance of diffraction-unlimited fluorescence microscopy opens up a pathway for addressing fundamental problems in the life sciences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Self-citationBeiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Self-citationSTED microscopy reveals that synaptotagmin remains clustered after synaptic vesicle exocytosis
Willig, K. I., Rizzoli, S. O., Westphal, V., Jahn, R., & Hell, S. W. (2006) · Nature · doi:10.1038/nature04592 · Cited by 1,225
Self-citationCell Biology: a Laboratory Handbook
Harris, A. (1995) · Journal of Medical Genetics · doi:10.1136/jmg.32.9.759 · Cited by 1,225
Cell biology :a laboratory handbook.
Celis, J. E. (1994) · Cited by 1,209
Hell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Self-citation
Cited by
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
“Applying this resolution in immunofluorescence imaging has initially been hampered by photobleaching, but allowing long-lived fluorophore dark states to relax, enabled Δr = 20–30 nm also in cells [85,86].”
BackgroundSelf-citationSuper-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
“STED has been applied to biological samples either immunostained with fluorophorelabeled antibodies (26) or genetically tagged with fluorescent proteins (FPs) (27).”
BackgroundMethodFluorescent probes for super-resolution imaging in living cells
Fernández-Suárez, M., & Ting, A. Y. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2531 · Cited by 1,306
A guide to super-resolution fluorescence microscopy
Schermelleh, L., Heintzmann, R., & Leonhardt, H. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201002018 · Cited by 1,255
Schermelleh, L., Carlton, P. M., Haase, S., Shao, L., Winoto, L., Kner, P., Burke, B., Cardoso, M. C., Agard, D. A., Gustafsson, M. G. L., et al. (2008) · Science · doi:10.1126/science.1156947 · Cited by 1,123
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Self-citationSingle-molecule localization microscopy
Lelek, M., Gyparaki, M. T., Beliu, G., Schueder, F., Griffié, J., Manley, S., Jungmann, R., Sauer, M., Lakadamyali, M., & Zimmer, C. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00038-x · Cited by 954
The interaction of cells and bacteria with surfaces structured at the nanometre scale
Anselme, K., Davidson, P., Popa, A. M., Giazzon, M., Liley, M., & Ploux, L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.04.001 · Cited by 827
STED microscopy reveals crystal colour centres with nanometric resolution
Rittweger, E., Han, K. Y., Irvine, S. E., Eggeling, C., & Hell, S. W. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.2 · Cited by 818
Self-citationVideo-Rate Far-Field Optical Nanoscopy Dissects Synaptic Vesicle Movement
Westphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., Jahn, R., & Hell, S. W. (2008) · Science · doi:10.1126/science.1154228 · Cited by 788
Self-citationSTED super-resolved microscopy
Vicidomini, G., Bianchini, P., & Diaspro, A. (2018) · Nature Methods · doi:10.1038/nmeth.4593 · Cited by 717
Diamond-based single-photon emitters
Aharonovich, I., Castelletto, S., Simpson, D. A., Su, C.-H., Greentree, A. D., & Prawer, S. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/7/076501 · Cited by 590
Tunable nanowire nonlinear optical probe
Nakayama, Y., Pauzauskie, P. J., Radenovic, A., Onorato, R. M., Saykally, R. J., Liphardt, J., & Yang, P. (2007) · Nature · doi:10.1038/nature05921 · Cited by 586
Emerging views of the nucleus as a cellular mechanosensor
Kirby, T. J., & Lammerding, J. (2018) · Nature Cell Biology · doi:10.1038/s41556-018-0038-y · Cited by 564
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
STED microscopy with continuous wave beams
Willig, K. I., Harke, B., Medda, R., & Hell, S. W. (2007) · Nature Methods · doi:10.1038/nmeth1108 · Cited by 523
Self-citationYork, A. G., Parekh, S. H., Nogare, D. D., Fischer, R. S., Temprine, K., Mione, M., Chitnis, A. B., Combs, C. A., & Shroff, H. (2012) · Nature Methods · doi:10.1038/nmeth.2025 · Cited by 472
Anatomy and Dynamics of a Supramolecular Membrane Protein Cluster
Sieber, J. J., Willig, K. I., Kutzner, C., Gerding-Reimers, C., Harke, B., Donnert, G., Rammner, B., Eggeling, C., Hell, S. W., Grubmüller, H., et al. (2007) · Science · doi:10.1126/science.1141727 · Cited by 461
Self-citationNew directions in single-molecule imaging and analysis
Moerner, W. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610081104 · Cited by 440
Cell-cell communication: New insights and clinical implications
Su, J., Song, Y., Zhu, Z., Huang, X., Fan, J., Qiao, J., & Mao, F. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01888-z · Cited by 433
Sharper low-power STED nanoscopy by time gating
Vicidomini, G., Moneron, G., Han, K. Y., Westphal, V., Ta, H., Reuss, M., Engelhardt, J., Eggeling, C., & Hell, S. W. (2011) · Nature Methods · doi:10.1038/nmeth.1624 · Cited by 423
Self-citationTwo-Color Single-Photon Photoinitiation and Photoinhibition for Subdiffraction Photolithography
Scott, T. F., Kowalski, B. A., Sullivan, A. C., Bowman, C. N., & McLeod, R. R. (2009) · Science · doi:10.1126/science.1167610 · Cited by 421
Lanthanide-doped up-converting nanoparticles: Merits and challenges
Gnach, A., & Bednarkiewicz, A. (2012) · Nano Today · doi:10.1016/j.nantod.2012.10.006 · Cited by 393
Separation, characterization and identification of microplastics and nanoplastics in the environment
Fu, W., Min, J., Jiang, W., Li, Y., & Zhang, W. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.137561 · Cited by 361
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
Synaptic vesicle recycling: steps and principles
Rizzoli, S. O. (2014) · The EMBO Journal · doi:10.1002/embj.201386357 · Cited by 317
“In neuroendocrine cells most of the SV proteins can be found in endosomes (Donnert et al , 2006, 2007), although it is unclear whether the proteins have reached the endosomes directly from the Golgi or after endocytosis from the plasma membrane (see below steps 23 – 25).”
Self-citationAdaptive optics enables 3D STED microscopy in aberrating specimens
Gould, T. J., Burke, D., Bewersdorf, J., & Booth, M. J. (2012) · Optics Express · doi:10.1364/oe.20.020998 · Cited by 315
Major signal increase in fluorescence microscopy through dark-state relaxation
Donnert, G., Eggeling, C., & Hell, S. W. (2007) · Nature Methods · doi:10.1038/nmeth986 · Cited by 291
Self-citationAdvances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
STED microscopy with a supercontinuum laser source
Wildanger, D., Rittweger, E., Kastrup, L., & Hell, S. W. (2008) · Optics Express · doi:10.1364/oe.16.009614 · Cited by 277
Self-citationHigh-speed AFM and nano-visualization of biomolecular processes
Ando, T., Uchihashi, T., Kodera, N., Yamamoto, D., Miyagi, A., Taniguchi, M., & Yamashita, H. (2008) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0406-0 · Cited by 262
Two-Color Far-Field Fluorescence Nanoscopy
Donnert, G., Keller, J., Wurm, C. A., Rizzoli, S. O., Westphal, V., Schönle, A., Jahn, R., Jakobs, S., Eggeling, C., & Hell, S. W. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104497 · Cited by 256
Self-citationMulticolor Far-Field Fluorescence Nanoscopy through Isolated Detection of Distinct Molecular Species
Bossi, M., Fölling, J., Belov, V. N., Boyarskiy, V. P., Medda, R., Egner, A., Eggeling, C., Schönle, A., & Hell, S. W. (2008) · Nano Letters · doi:10.1021/nl801471d · Cited by 253
Self-citationTwo-photon excitation STED microscopy
Moneron, G., & Hell, S. W. (2009) · Optics Express · doi:10.1364/oe.17.014567 · Cited by 238
Self-citationSchneider, A., Rajendran, L., Honsho, M., Gralle, M., Donnert, G., Wouters, F., Hell, S. W., & Simons, M. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.5345-07.2008 · Cited by 210
Self-citationAn introduction to optical super-resolution microscopy for the adventurous biologist
Vangindertael, J., Camacho, R., Sempels, W., Mizuno, H., Dedecker, P., & Janssen, K. P. F. (2018) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/aaae0c · Cited by 208
“Moreover, due to the long lifetime of the T1 state, there is a significant risk of ‘pile up’ or saturation of this state, further increasing the risk of T1-Tn transitions [72].”
BackgroundInfluentialNishiyama, H., Suga, M., Ogura, T., Maruyama, Y., Koizumi, M., Mio, K., Kitamura, S., & Sato, C. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.01.005 · Cited by 195
Multilayer three-dimensional super resolution imaging of thick biological samples
Vaziri, A., Tang, J., Shroff, H., & Shank, C. V. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810636105 · Cited by 180
Lin, W., Margolskee, R., Donnert, G., Hell, S. W., & Restrepo, D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610201104 · Cited by 173
Self-citationYork, A. G., Ghitani, A., Vaziri, A., Davidson, M. W., & Shroff, H. (2011) · Nature Methods · doi:10.1038/nmeth.1571 · Cited by 172
“, whereas 3D stimulated emission depletion microscop”
Laser-Stimulated Fluorescence in Paleontology
Kaye, T. G., Falk, A. R., Pittman, M., Sereno, P. C., Martin, L. D., Burnham, D. A., Gong, E., Xu, X., & Wang, Y. (2015) · PLOS ONE · doi:10.1371/journal.pone.0125923 · Cited by 76
Chiral and nematic phases of flexible active filaments
Dunajova, Z., Mateu, B. P., Radler, P., Lim, K., Brandis, D., Velicky, P., Danzl, J. G., Wong, R. W., Elgeti, J., Hannezo, E., et al. (2023) · Nature Physics · doi:10.1038/s41567-023-02218-w · Cited by 23
Chiral and nematic phases of flexible active filaments
Dunajova, Z., Mateu, B. P., Radler, P., Lim, K., Velicky, P., Danzl, J. G., Wong, R. W., Elgeti, J., Hannezo, E., & Loose, M. (2022) · doi:10.1101/2022.12.15.520425 · Cited by 2
Metadata
- Authors
- Donnert, G., Keller, J., Medda, R., Andrei, M. A., Rizzoli, S. O., Lührmann, R., Jahn, R., Eggeling, C., & Hell, S. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-08
- Volume
- 103
- Issue
- 31
- Pages
- 11440-11445
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2109168096
- Cited by
- 527
- References
- 35
- FWCI
- 24.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.