Microfluidic immunoassays as rapid saliva-based clinical diagnostics
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
At present, point-of-care (POC) diagnostics typically provide a binary indication of health status (e.g., home pregnancy test strip). Before anticipatory use of diagnostics for assessment of complex diseases becomes widespread, development of sophisticated bioassays capable of quantitatively measuring disease biomarkers is necessary. Successful translation of new bioassays into clinical settings demands the ability to monitor both the onset and progression of disease. Here we report on a clinical POC diagnostic that enables rapid quantitation of an oral disease biomarker in human saliva by using a monolithic disposable cartridge designed to operate in a compact analytical instrument. Our microfluidic method facilitates hands-free saliva analysis by integrating sample pretreatment (filtering, enrichment, mixing) with electrophoretic immunoassays to quickly measure analyte concentrations in minimally pretreated saliva samples. Using 20 μl of saliva, we demonstrate rapid (<10 min) measurement of the collagen-cleaving enzyme matrix metalloproteinase-8 (MMP-8) in saliva from healthy and periodontally diseased subjects. In addition to physiologically measurable indicators of periodontal disease, conventional measurements of salivary MMP-8 were used to validate the microfluidic assays described in this proof-of-principle study. The microchip-based POC diagnostic demonstrated is applicable to rapid, reliable measurement of proteinaceous disease biomarkers in biological fluids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Matrix metalloproteinases (MMPs) in oral diseases
Sorsa, T., Tjäderhane, L., & Salo, T. (2004) · Oral Diseases · doi:10.1111/j.1601-0825.2004.01038.x · Cited by 618
Scannapieco, F. A., Bush, R. B., & Paju, S. (2003) · Annals of Periodontology · doi:10.1902/annals.2003.8.1.54 · Cited by 501
Host Responses in Periodontal Diseases: Current Concepts
Genco, R. J. (1992) · Journal of Periodontology · doi:10.1902/jop.1992.63.4s.338 · Cited by 464
Systemic Effects of Periodontitis: Epidemiology of Periodontal Disease and Cardiovascular Disease
Beck, J. D., & Offenbacher, S. (2005) · Journal of Periodontology · doi:10.1902/jop.2005.76.11-s.2089 · Cited by 447
Analysis of saliva for periodontal diagnosis: A review
Kaufman, E., & Lamster, I. B. (2000) · Journal of Clinical Periodontology · doi:10.1034/j.1600-051x.2000.027007453.x · Cited by 388
Streckfus, C., & Bigler, L. (2002) · Oral Diseases · doi:10.1034/j.1601-0825.2002.1o834.x · Cited by 374
Salivary diagnostics powered by nanotechnologies, proteomics and genomics
Wong, D. T. (2006) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2006.0180 · Cited by 367
Malamud, D. (1992) · BMJ · doi:10.1136/bmj.305.6847.207 · Cited by 362
Cited by
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Innovations in optical microfluidic technologies for point-of-care diagnostics
Myers, F. B., & Lee, L. P. (2008) · Lab on a Chip · doi:10.1039/b812343h · Cited by 474
Saliva diagnostics – Current views and directions
Kaczor-Urbanowicz, K. E., Martin Carreras-Presas, C., Aro, K., Tu, M., Garcia-Godoy, F., & Wong, D. T. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370216681550 · Cited by 472
Saliva as a diagnostic tool for oral and systemic diseases
Javaid, M. A., Ahmed, A. S., Durand, R., & Tran, S. D. (2016) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2015.08.006 · Cited by 431
Microfluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398
Current Developments in Salivary Diagnostics
Miller, C. S., Foley, J. D., Bailey, A. L., Campell, C. L., Humphries, R. L., Christodoulides, N., Floriano, P. N., Simmons, G., Bhagwandin, B., Jacobson, J. W., et al. (2010) · Biomarkers in Medicine · doi:10.2217/bmm.09.68 · Cited by 389
Identification of Pathogen and Host‐Response Markers Correlated With Periodontal Disease
Ramseier, C. A., Kinney, J. S., Herr, A. E., Braun, T., Sugai, J. V., Shelburne, C. A., Rayburn, L. A., Tran, H. M., Singh, A. K., & Giannobile, W. V. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.080480 · Cited by 382
Self-citationSaliva as a diagnostic tool for periodontal disease: current state and future directions
Giannobile, W. V., Beikler, T., Kinney, J. S., Ramseier, C. A., Morelli, T., & Wong, D. T. (2009) · Periodontology 2000 · doi:10.1111/j.1600-0757.2008.00288.x · Cited by 381
Self-citationSaliva: diagnostics and therapeutic perspectives
Spielmann, N., & Wong, D. (2011) · Oral Diseases · doi:10.1111/j.1601-0825.2010.01773.x · Cited by 378
Protein immobilization techniques for microfluidic assays
Kim, D., & Herr, A. E. (2013) · Biomicrofluidics · doi:10.1063/1.4816934 · Cited by 376
Self-citationOptical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Nano/Microfluidics for diagnosis of infectious diseases in developing countries
Lee, W. G., Kim, Y.-G., Chung, B. G., Demirci, U., & Khademhosseini, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.016 · Cited by 357
Immunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Pattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., et al. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02502-2 · Cited by 330
Saliva: A potential media for disease diagnostics and monitoring
Liu, J., & Duan, Y. (2012) · Oral Oncology · doi:10.1016/j.oraloncology.2012.01.021 · Cited by 308
Electrochemical Sensor for Multiplex Biomarkers Detection
Wei, F., Patel, P., Liao, W., Chaudhry, K., Zhang, L., Arellano-Garcia, M., Hu, S., Elashoff, D., Zhou, H., Shukla, S., et al. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-09-0050 · Cited by 257
Jokerst, J. V., Raamanathan, A., Christodoulides, N., Floriano, P. N., Pollard, A. A., Simmons, G. W., Wong, J., Gage, C., Furmaga, W. B., Redding, S. W., et al. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.05.026 · Cited by 253
Protein separation by capillary gel electrophoresis: A review
Zhu, Z., Lu, J. J., & Liu, S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.10.022 · Cited by 202
Salivary biomarkers: novel noninvasive tools to diagnose chronic inflammation
Dongiovanni, P., Meroni, M., Casati, S., Goldoni, R., Thomaz, D. V., Kehr, N. S., Galimberti, D., Del Fabbro, M., & Tartaglia, G. M. (2023) · International Journal of Oral Science · doi:10.1038/s41368-023-00231-6 · Cited by 197
Floriano, P. N., Christodoulides, N., Miller, C. S., Ebersole, J. L., Spertus, J., Rose, B. G., Kinane, D. F., Novak, M. J., Steinhubl, S., Acosta, S., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.117713 · Cited by 190
Sorsa, T., Hernández, M., Leppilahti, J., Munjal, S., Netuschil, L., & Mäntylä, P. (2010) · Oral Diseases · doi:10.1111/j.1601-0825.2009.01603.x · Cited by 177
A digital microfluidic system for serological immunoassays in remote settings
Ng, A. H. C., Fobel, R., Fobel, C., Lamanna, J., Rackus, D. G., Summers, A., Dixon, C., Dryden, M. D. M., Lam, C., Ho, M., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aar6076 · Cited by 172
Capillary electrophoresis and isoelectric focusing in peptide and protein analysis
Righetti, P. G., Sebastiano, R., & Citterio, A. (2013) · PROTEOMICS · doi:10.1002/pmic.201200378 · Cited by 166
“[132] recently integrated saliva pretreatment (mixing, incubation, and enrichment) with subsequent quantitative immunoassays and measured the concentration of endogenous MMP-8 in saliva.”
Background
Metadata
- Authors
- Herr, A. E., Hatch, A. V., Throckmorton, D. J., Tran, H. M., Brennan, J. S., Giannobile, W. V., & Singh, A. K.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-03-27
- Volume
- 104
- Issue
- 13
- Pages
- 5268-5273
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1986373434
- Cited by
- 389
- References
- 34
- FWCI
- 25.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.