Biomimetic tissue-engineered anterior cruciate ligament replacement
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
There are >200,000 anterior cruciate ligament (ACL) ruptures each year in the United States, and, due to the poor healing properties of the ACL, surgical reconstruction with autograft or allograft tissue is the current treatment of these injuries. To regenerate the ACL, the ideal matrix should be biodegradable, porous, and exhibit sufficient mechanical strength to allow formation of neoligament tissue. Researchers have developed ACL scaffolds with collagen fibers, silk, biodegradable polymers, and composites with limited success. Our group has developed a biomimetic ligament replacement by using 3D braiding technology. In this preliminary in vivo rabbit model study for ACL reconstruction, the histological and mechanical evaluation demonstrated excellent healing and regeneration with our cell-seeded, tissue-engineered ligament replacement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Culture of Animal Cells: A Manual of Basic Technique and Specialized Applications
Freshney, R. I. (2010) · Wiley eBooks · doi:10.1002/9780470649367 · Cited by 3,870
Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions.
Noyes, F. R., Butler, D. L., Grood, E. S., Zernicke, R. F., & Hefzy, M. S. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00005 · Cited by 1,524
Laboratory methods in histotechnology
Prophet, E. B. (1992) · Medical Entomology and Zoology · Cited by 915
Basic Biomechanics of the Musculoskeletal System
Nordin, E. B. M., & Frankel, V. H. (1989) · Medical Entomology and Zoology · Cited by 871
Silk matrix for tissue engineered anterior cruciate ligaments
Altman, G. H., Horan, R. L., Lu, H. H., Moreau, J., Martin, I., Richmond, J. C., & Kaplan, D. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00156-4 · Cited by 863
Tissue Engineering: Orthopedic Applications
Laurencin, C. T., Ambrosio, A. M. A., Borden, M. D., & Cooper, J. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.19 · Cited by 752
Self-citationHandbook of Biomaterial Properties
Black, J. T. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5801-9 · Cited by 734
Encyclopedic handbook of biomaterials and bioengineering
Wise, D. L. (1995) · Cited by 584
Culture of animal cells: A manual of basic technique
Borek, F. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(95)90024-1 · Cited by 501
Cooper, J. A., Lu, H. H., Ko, F. K., Freeman, J. W., & Laurencin, C. T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.014 · Cited by 481
Self-citationBasic Biomechanics of the Musculoskeletal System
Ranu, H. S. (1989) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-198912000-00011 · Cited by 438
Biological Performance Of Materials - Fundamentals Of Biocompatibility
Black, J. (1992) · Cited by 388
Lu, H. H., Cooper, J. A., Manuel, S., Freeman, J. W., Attawia, M. A., Ko, F. K., & Laurencin, C. T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.050 · Cited by 380
Self-citationArnoczky, S. P., Warren, R. F., & Ashlock, M. A. (1986) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198668030-00010 · Cited by 308
Biomechanics of Knee Ligaments
Woo, S. L.-Y., Debski, R. E., Withrow, J. D., & Janaushek, M. A. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270042301 · Cited by 293
Ballock, R. T., Woo, S. L., Lyon, R. M., Hollis, J. M., & Akeson, W. H. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070404 · Cited by 230
Nagineni, C. N., Amiel, D., Green, M. H., Berchuck, M., & Akeson, W. H. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100402 · Cited by 198
Analysis of Retrieved Polymer Fiber Based Replacements for the ACL
Guidoin, M.-F., Marois, Y., Bejui, J., Poddevin, N., King, M. W., & Guidoin, R. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00114-9 · Cited by 197
Danto, M. I., & Woo, S. L. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110108 · Cited by 193
Biological performance of materials: fundamentals of biocompatibility
Bozentka, D. J. (1993) · The Journal of Hand Surgery · doi:10.1016/0363-5023(93)90416-z · Cited by 185
Biology and Biomechanics of the Anterior Cruciate Ligament
Smith, B. A., Livesay, G. A., & Woo, S. L. (1993) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(20)30380-x · Cited by 152
Dunn, M. G., Tria, A. J., Kato, Y. P., Bechler, J. R., Ochner, R. S., Zawadsky, J. P., & Silver, F. H. (1992) · The American Journal of Sports Medicine · doi:10.1177/036354659202000504 · Cited by 134
COOPERJR, J., Bailey, L. O., Carter, J. N., Castiglioni, C., Kofron, M. D., Ko, F. K., & Laurencin, C. T. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.013 · Cited by 110
Self-citationImplantation biology : the host response and biomedical devices
Greco, R. S. (1994) · CRC Press eBooks · Cited by 86
Laitinen, O., Törmälä, P., Taurio, R., Skutnabb, K., Saarelainen, K., Iivonen, T., & Vainionpää, S. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90152-e · Cited by 77
Hart, R. A., Woo, S. L., & Newton, P. O. (1992) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100100112 · Cited by 75
Ligaments and ligamentoplasties
Yahia, H. (1997) · Springer eBooks · Cited by 55
Engle, C. P., Noguchi, M., Ohland, K. J., Shelley, F. J., & Woo, S. L. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120308 · Cited by 33
Laitinen, O., Pohjonen, T., T�rm�l�, P., Saarelainen, K., Vasenius, J., Rokkanen, P., & Vainionp��, S. (1993) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00452963 · Cited by 33
Biomechanical and histological changes in the patellar tendon after in situ freezing
Ohno, K., Yasuda, K., Yamamoto, N., Kaneda, K., & Hayashi, K. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00075-5 · Cited by 21
Espregueira‐Mendes, J., Lopes, J. M., Castro, C., & Oliveira, J. P. (1998) · The Knee · doi:10.1016/s0968-0160(97)00018-5 · Cited by 7
Cited by
Complexity in biomaterials for tissue engineering
Place, E. S., Evans, N. D., & Stevens, M. M. (2009) · Nature Materials · doi:10.1038/nmat2441 · Cited by 1,728
Poly (lactic acid)-based biomaterials for orthopaedic regenerative engineering
Narayanan, G., Vernekar, V. N., Kuyinu, E. L., & Laurencin, C. T. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.015 · Cited by 484
Self-citationFiber-based tissue engineering: progress, challenges, and opportunities
Tamayol, A., Akbari, M., Annabi, N., Paul, A., Khademhosseini, A., & Juncker, D. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.11.007 · Cited by 458
“(Cooper et al., 2007) − The stress–strain curve was similar to the values for natural ligament tissue − The 3D circular fibrous scaffold could withstand the tensile load applied on”
BackgroundMethodResultInfluentialFunctional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering
Lu, H. H., & Thomopoulos, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124656 · Cited by 447
Engineering Orthopedic Tissue Interfaces
Yang, P. J., & Temenoff, J. S. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0371 · Cited by 294
Metadata
- Authors
- Cooper, J. A., Sahota, J. S., Gorum, W. J., Carter, J., Doty, S. B., & Laurencin, C. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-02-27
- Volume
- 104
- Issue
- 9
- Pages
- 3049-3054
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2167689517
- Cited by
- 186
- References
- 31
- FWCI
- 12.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.