Label-free and dynamic detection of biomolecular interactions for high-throughput microarray applications
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Direct monitoring of primary molecular-binding interactions without the need for secondary reactants would markedly simplify and expand applications of high-throughput label-free detection methods. A simple interferometric technique is presented that monitors the optical phase difference resulting from accumulated biomolecular mass. As an example, 50 spots for each of four proteins consisting of BSA, human serum albumin, rabbit IgG, and protein G were dynamically monitored as they captured corresponding antibodies. Dynamic measurements were made at 26 pg/mm 2 SD per spot and with a detectable concentration of 19 ng/ml. The presented method is particularly relevant for protein microarray analysis because it is label-free, simple, sensitive, and easily scales to high-throughput.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Schena, M., Shalon, D., Davis, R. W., & Brown, P. O. (1995) · Science · doi:10.1126/science.270.5235.467 · Cited by 9,609 · cited 1×
“The importance of high-throughput platforms has been demonstrated by the success of gene arrays in the analysis of nucleic acids (7, 8).”
BackgroundEnzyme-linked immunosorbent assay (ELISA) quantitative assay of immunoglobulin G
Engvall, E., & Perlmann, P. (1971) · Immunochemistry · doi:10.1016/0019-2791(71)90454-x · Cited by 3,777
Printing Proteins as Microarrays for High-Throughput Function Determination
MacBeath, G., & Schreiber, S. L. (2000) · Science · doi:10.1126/science.289.5485.1760 · Cited by 2,767 · cited 1×
“This success has further provided impetus for the proposal that protein–peptide arrays could achieve similar utility for the analysis of multiple binding events (9, 10).”
BackgroundOptical waves in layered media
(1989) · Choice Reviews Online · doi:10.5860/choice.26-6299 · Cited by 2,173
Microarray data normalization and transformation
Quackenbush, J. (2002) · Nature Genetics · doi:10.1038/ng1032 · Cited by 1,975
Global Analysis of Protein Activities Using Proteome Chips
Zhu, H., Bilgin, M., Bangham, R., Hall, D., Casamayor, A., Bertone, P., Lan, N., Jansen, R., Bidlingmaier, S., Houfek, T., et al. (2001) · Science · doi:10.1126/science.1062191 · Cited by 1,884 · cited 1×
“This success has further provided impetus for the proposal that protein–peptide arrays could achieve similar utility for the analysis of multiple binding events (9, 10).”
BackgroundSelf-Assembled Organic Monolayers: Model Systems for Studying Adsorption of Proteins at Aurfaces
Prime, K. L., & Whitesides, G. M. (1991) · Science · doi:10.1126/science.252.5009.1164 · Cited by 1,831 · cited 1×
“45, commonly used as the refractive index of a monolayer of protein (15, 16).”
BackgroundDe Feijter, J. A., Benjamins, J., & Veer, F. A. (1978) · Biopolymers · doi:10.1002/bip.1978.360170711 · Cited by 1,289
Proteomic applications for the early detection of cancer
Wulfkuhle, J. D., Liotta, L. A., & Petricoin, E. F. (2003) · Nature Reviews Cancer · doi:10.1038/nrc1043 · Cited by 907
Protein blotting: Principles and applications
Gershoni, J. M., & Palade, G. E. (1983) · Analytical Biochemistry · doi:10.1016/0003-2697(83)90128-8 · Cited by 853 · cited 1×
“Antigen–antibody, receptor–ligand, virus–cell and protein– DNA binding interactions are monitored and quantified in biological and medical research by long established and extensively used solid-phase immunoassays such as enzyme-linked immunosorbent assays (ELISA) (1) and Western blotting (2).”
BackgroundSelf-citationSURVEY AND SUMMARY: From DNA biosensors to gene chips
Wang, J. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.16.3011 · Cited by 753
Enzyme-linked Immunosorbent Assay, ELISA
ENGVALL, E., & PERLMANN, P. (1972) · Protides of the Biological Fluids · doi:10.1016/b978-0-08-016876-0.50102-x · Cited by 585
Rapid analysis of the DNA-binding specificities of transcription factors with DNA microarrays
Mukherjee, S., Berger, M. F., Jona, G., Wang, X. S., Muzzey, D., Snyder, M., Young, R. A., & Bulyk, M. L. (2004) · Nature Genetics · doi:10.1038/ng1473 · Cited by 373 · cited 1×
“Proteomic microarrays have a wide range of applications, varying from parallel detection of antibodies for diagnosis of allergies and infectious diseases (26), to early detection of cancer (27), peptide analysis (28), identifying promoter sequences recognized by various transcription factors (29), and even to the dete…”
BackgroundColorimetric resonant reflection as a direct biochemical assay technique
Cunningham, B. T., Li, P., Lin, B., & Pepper, J. W. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00976-5 · Cited by 359
A perspective on protein microarrays
Mitchell, P. (2002) · Nature Biotechnology · doi:10.1038/nbt0302-225 · Cited by 313 · cited 2×
“Thus, label-free measurement of binding events is a potentially powerful tool, simpler and more efficient than secondary probebased systems (3).”
BackgroundLarge-scale functional analysis using peptide or protein arrays
Emili, A. Q., & Cagney, G. (2000) · Nature Biotechnology · doi:10.1038/74442 · Cited by 238 · cited 1×
“Proteomic microarrays have a wide range of applications, varying from parallel detection of antibodies for diagnosis of allergies and infectious diseases (26), to early detection of cancer (27), peptide analysis (28), identifying promoter sequences recognized by various transcription factors (29), and even to the dete…”
BackgroundAntigen Microarrays for Serodiagnosis of Infectious Diseases
Mezzasoma, L., Bacarese-Hamilton, T., Cristina, M. D., Rossi, R., Bistoni, F., & Crisanti, A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.1.121 · Cited by 211 · cited 1×
“Proteomic microarrays have a wide range of applications, varying from parallel detection of antibodies for diagnosis of allergies and infectious diseases (26), to early detection of cancer (27), peptide analysis (28), identifying promoter sequences recognized by various transcription factors (29), and even to the dete…”
BackgroundEmerging tools for real‐time label‐free detection of interactions on functional protein microarrays
Ramachandran, N., Larson, D. N., Stark, P. R. H., Hainsworth, E., & LaBaer, J. (2005) · FEBS Journal · doi:10.1111/j.1742-4658.2005.04971.x · Cited by 171 · cited 1×
“Label-free detection has been demonstrated by using electrical, electromechanical, and optical detection methods (4).”
MethodInterference-based detection of nucleic acid targets on optically coated silicon
JENISON, R. D., Yang, S., Haeberli, A., & Polisky, B. A. (2001) · Nature Biotechnology · doi:10.1038/83530 · Cited by 110
Zhu, X., Landry, J. P., Sun, Y.-S., Gregg, J. P., Lam, K. S., & Guo, X. (2007) · Applied Optics · doi:10.1364/ao.46.001890 · Cited by 72
Cited by
Adato, R., & Altug, H. (2013) · Nature Communications · doi:10.1038/ncomms3154 · Cited by 406
Advances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Detection of cancer biomarkers in serum using a hybrid mechanical and optoplasmonic nanosensor
Kosaka, P. M., Pini, V., Ruz, J. J., da Silva, R. A., González, M. U., Ramos, D., Calleja, M., & Tamayo, J. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.250 · Cited by 278
Label-free optical resonant sensors for biochemical applications
Ciminelli, C., Campanella, C. M., Dell’Olio, F., Campanella, C. E., & Armenise, M. N. (2013) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2013.02.001 · Cited by 199
Metadata
- Authors
- Özkumur, E., Needham, J. W., Bergstein, D. A., Gonzalez, R., Cabodi, M., Gershoni, J. M., Goldberg, B. B., & Ünlü, M. S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-06-10
- Volume
- 105
- Issue
- 23
- Pages
- 7988-7992
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2149214991
- Cited by
- 177
- References
- 20
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.