Desorption electrospray ionization mass spectrometry: Imaging drugs and metabolites in tissues
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Ambient ionization methods for MS enable direct, high-throughput measurements of samples in the open air. Here, we report on one such method, desorption electrospray ionization (DESI), which is coupled to a linear ion trap mass spectrometer and used to record the spatial intensity distribution of a drug directly from histological sections of brain, lung, kidney, and testis without prior chemical treatment. DESI imaging provided identification and distribution of clozapine after an oral dose of 50 mg/kg by:i) measuring the abundance of the intact ion at m/z 327.1, and ii) monitoring the dissociation of the protonated drug compound at m/z 327.1 to its dominant product ion at m/z 270.1. In lung tissues, DESI imaging was performed in the full-scan mode over an m/z range of 200-1100, providing an opportunity for relative quantitation by using an endogenous lipid to normalize the signal response of clozapine. The presence of clozapine was detected in all tissue types, whereas the presence of the N-desmethyl metabolite was detected only in the lung sections. Quantitation of clozapine from the brain, lung, kidney, and testis, by using LC-MS/MS, revealed concentrations ranging from 0.05 μg/g (brain) to a high of 10.6 μg/g (lung). Comparisons of the results recorded by DESI with those by LC-MS/MS show good agreement and are favorable for the use of DESI imaging in drug and metabolite detection directly from biological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Self-citationCooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
Self-citationStoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172
Ollinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Takáts, Z., Wiseman, J. M., & Cooks, R. G. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.922 · Cited by 880
Self-citationNemes, P., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac071181r · Cited by 817
Wiseman, J. M., Ifa, D. R., Song, Q., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200602449 · Cited by 626
Self-citationDirect Molecular Analysis of Whole-Body Animal Tissue Sections by Imaging MALDI Mass Spectrometry
Khatib-Shahidi, S., Andersson, M., Herman, J. L., Gillespie, T. A., & Caprioli, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac060788p · Cited by 505
Clathrate nanostructures for mass spectrometry
Northen, T. R., Yanes, O., Northen, M. T., Marrinucci, D., Uritboonthai, W., Apon, J., Golledge, S. L., Nordström, A., & Siuzdak, G. (2007) · Nature · doi:10.1038/nature06195 · Cited by 480
Cited by
Development, Characterization, and Application of Paper Spray Ionization
Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z. (2010) · Analytical Chemistry · doi:10.1021/ac902854g · Cited by 711
Self-citationBanerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Self-citationA concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Weston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry
Laskin, J., Heath, B. S., Roach, P. J., Cazares, L., & Semmes, O. J. (2012) · Analytical Chemistry · doi:10.1021/ac2021322 · Cited by 338
Sample preparation for mass spectrometry imaging: Small mistakes can lead to big consequences
Goodwin, R. J. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.012 · Cited by 313
Advances in Imaging Secondary Ion Mass Spectrometry for Biological Samples
Boxer, S. G., Kraft, M. L., & Weber, P. K. (2009) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.050708.133634 · Cited by 308
Ambient Ionization Mass Spectrometry
Huang, M.-Z., Yuan, C.-H., Cheng, S.-C., Cho, Y.-T., & Shiea, J. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073702 · Cited by 306
Taylor, M. J., Lukowski, J. K., & Anderton, C. R. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00439 · Cited by 302
Mass spectrometry imaging for drug distribution studies
Prideaux, B., & Stoeckli, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.07.028 · Cited by 279
Eberlin, L. S., Ferreira, C. R., Dill, A. L., Ifa, D. R., & Cooks, R. G. (2011) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2011.05.006 · Cited by 257
Self-citationAutoradiography, MALDI-MS, and SIMS-MS Imaging in Pharmaceutical Discovery and Development
Solon, E. G., Schweitzer, A., Stoeckli, M., & Prideaux, B. (2010) · The AAPS Journal · doi:10.1208/s12248-009-9158-4 · Cited by 250
“Alternative desorption technologies suitable for MSI, including surface sampling (62) and desorption electrospray (63), are still in early development stages and are not discussed in this article.”
Sumner, L. W., Lei, Z., Nikolau, B. J., & Saito, K. (2015) · Natural Product Reports · doi:10.1039/c4np00072b · Cited by 233
Vaysse, P.-M., Heeren, R. M. A., Porta, T., & Balluff, B. (2017) · The Analyst · doi:10.1039/c7an00565b · Cited by 215
Mass Spectrometry Imaging in Drug Development
Nilsson, A., Goodwin, R. J. A., Shariatgorji, M., Vallianatou, T., Webborn, P. J. H., & Andrén, P. E. (2015) · Analytical Chemistry · doi:10.1021/ac504734s · Cited by 191
Quantitative Mass Spectrometry Imaging of Biological Systems
Unsihuay, D., Mesa Sanchez, D., & Laskin, J. (2021) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-061020-053416 · Cited by 189
“Meanwhile, a majority of MSI experiments involving liquid extraction-based techniques have relied on desorption electrospray ionization (DESI) (27, 28) and its variants along with nanospray desorption electrospray ionization (nano-DESI) (29), liquid microjunction surface sampling probe (LMJ-SSP) (30), and liquid extra…”
BackgroundMikhailov, V. A., Griffiths, R. L., & Cooper, H. J. (2017) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2016.09.011 · Cited by 41
“DESI has been successfully applied to the surface analysis of small molecules, peptides and proteins up to ~ 25 kDa [27, 31, 32] , however direct analysis of intact proteins from biologically relevant samples has not been reported to date.”
Method
Metadata
- Authors
- Wiseman, J. M., Ifa, D. R., Zhu, Y., Kissinger, C. B., Manicke, N. E., Kissinger, P. T., & Cooks, R. G.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-11-25
- Volume
- 105
- Issue
- 47
- Pages
- 18120-18125
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2165041849
- Cited by
- 460
- References
- 35
- FWCI
- 14.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.