The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Electron microscopy of whole cells in liquid with nanometer resolution
Open accessAbstract
Single gold-tagged epidermal growth factor (EGF) molecules bound to cellular EGF receptors of fixed fibroblast cells were imaged in liquid with a scanning transmission electron microscope (STEM). The cells were placed in buffer solution in a microfluidic device with electron transparent windows inside the vacuum of the electron microscope. A spatial resolution of 4 nm and a pixel dwell time of 20 μs were obtained. The liquid layer was sufficiently thick to contain the cells with a thickness of 7 ± 1 μm. The experimental findings are consistent with a theoretical calculation. Liquid STEM is a unique approach for imaging single molecules in whole cells with significantly improved resolution and imaging speed over existing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
STED microscopy reveals that synaptotagmin remains clustered after synaptic vesicle exocytosis
Willig, K. I., Rizzoli, S. O., Westphal, V., Jahn, R., & Hell, S. W. (2006) · Nature · doi:10.1038/nature04592 · Cited by 1,225
Studying protein dynamics in living cells
Lippincott-Schwartz, J., Snapp, E., & Kenworthy, A. (2001) · Nature Reviews Molecular Cell Biology · doi:10.1038/35073068 · Cited by 1,190
Live-cell photoactivated localization microscopy of nanoscale adhesion dynamics
Shroff, H., Galbraith, C. G., Galbraith, J. A., & Betzig, E. (2008) · Nature Methods · doi:10.1038/nmeth.1202 · Cited by 873
Quantum dot ligands provide new insights into erbB/HER receptor–mediated signal transduction
Lidke, D. S., Nagy, P., Heintzmann, R., Arndt-Jovin, D. J., Post, J. N., Grecco, H. E., Jares-Erijman, E. A., & Jovin, T. M. (2004) · Nature Biotechnology · doi:10.1038/nbt929 · Cited by 828
Three-dimensional sub–100 nm resolution fluorescence microscopy of thick samples
Juette, M. F., Gould, T. J., Lessard, M. D., Mlodzianoski, M. J., Nagpure, B. S., Bennett, B. T., Hess, S. T., & Bewersdorf, J. (2008) · Nature Methods · doi:10.1038/nmeth.1211 · Cited by 812
Dynamic microscopy of nanoscale cluster growth at the solid–liquid interface
Williamson, M. J., Tromp, R. M., Vereecken, P. M., Hull, R., & Ross, F. M. (2003) · Nature Materials · doi:10.1038/nmat944 · Cited by 806
Video-Rate Far-Field Optical Nanoscopy Dissects Synaptic Vesicle Movement
Westphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., Jahn, R., & Hell, S. W. (2008) · Science · doi:10.1126/science.1154228 · Cited by 788
Crewe, A. V., Wall, J., & Langmore, J. (1970) · Science · doi:10.1126/science.168.3937.1338 · Cited by 752
From words to literature in structural proteomics
Sali, A., Glaeser, R., Earnest, T., & Baumeister, W. (2003) · Nature · doi:10.1038/nature01513 · Cited by 475
Hess, S. T., Gould, T. J., Gudheti, M. V., Maas, S. A., Mills, K. D., & Zimmerberg, J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708066104 · Cited by 373
High-resolution electron microscopy
Spence, J. C. H. (2018) · Physics Subject Headings (PhySH) · doi:10.29172/8f673cae6dc741ef8344e6da9556d0f7 · Cited by 286
Scanning electron microscopy of cells and tissues under fully hydrated conditions
Thiberge, S., Nechushtan, A., Sprinzak, D., Gileadi, O., Behar, V., Zik, O., Chowers, Y., Michaeli, S., Schlessinger, J., & Moses, E. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0400088101 · Cited by 253
X-ray tomography of whole cells
Le Gros, M. A., McDermott, G., & Larabell, C. A. (2005) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2005.08.008 · Cited by 226
High-resolution electron microscopy
Dyck, D. V. (2002) · Advances in imaging and electron physics · doi:10.1016/s1076-5670(02)80062-3 · Cited by 222
Wet STEM: A new development in environmental SEM for imaging nano-objects included in a liquid phase
Bogner, A., Thollet, G., Basset, D., Jouneau, P.-H., & Gauthier, C. (2005) · Ultramicroscopy · doi:10.1016/j.ultramic.2005.05.005 · Cited by 206
Dynein is required for receptor sorting and the morphogenesis of early endosomes
Driskell, O. J., Mironov, A., Allan, V. J., & Woodman, P. G. (2007) · Nature Cell Biology · doi:10.1038/ncb1525 · Cited by 183
Bacterial metapopulations in nanofabricated landscapes
Keymer, J. E., Galajda, P., Muldoon, C., Park, S., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607971103 · Cited by 165
Nano-Scale Dynamic Recognition Imaging on Vascular Endothelial Cells
Chtcheglova, L. A., Waschke, J., Wildling, L., Drenckhahn, D., & Hinterdorfer, P. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.109751 · Cited by 137
Nanotechnology in Biology and Medicine : Methods, Devices, and Applications
Vo‐Dinh, T. (2016) · Cited by 121
Daulton, T. L., Little, B. J., Lowe, K. L., et al. (2001) · Microscopy and Microanalysis · doi:10.1007/s10005-001-0021-3 · Cited by 118
Gai, P. L. (2002) · Microscopy and Microanalysis · doi:10.1017/s143192760201005x · Cited by 97
Sandison, D. R., Piston, D. W., Williams, R. M., et al. (1995) · Applied Optics · doi:10.1364/ao.34.003576 · Cited by 88
Self-citationIbaraki, N., Lin, L.-R., & Reddy, V. N. (1996) · Experimental Eye Research · doi:10.1006/exer.1996.0162 · Cited by 45
Sousa, A. A., Hohmann‐Marriott, M. F., Aronova, M. A., Zhang, G., & Leapman, R. D. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.01.007 · Cited by 32
Biological Scanning Transmission Electron Microscopy: Imaging and Single Molecule Mass Determination
Müller, S. A., & Engel, A. H. (2006) · CHIMIA International Journal for Chemistry · doi:10.2533/chimia.2006.749 · Cited by 31
Cited by
Observation of Single Colloidal Platinum Nanocrystal Growth Trajectories
Zheng, H., Smith, R. K., Jun, Y.-W., Kisielowski, C., Dahmen, U., & Alivisatos, A. P. (2009) · Science · doi:10.1126/science.1172104 · Cited by 1,337
Ma, X., Geiser-Lee, J., Deng, Y., & Kolmakov, A. (2010) · Science of The Total Environment · doi:10.1016/j.scitotenv.2010.03.031 · Cited by 1,263
Nanotechnology: A New Opportunity in Plant Sciences
Wang, P., Lombi, E., Zhao, F.-J., & Kopittke, P. M. (2016) · Trends in Plant Science · doi:10.1016/j.tplants.2016.04.005 · Cited by 1,062
Electron microscopy of specimens in liquid
de Jonge, N., & Ross, F. M. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.161 · Cited by 952
Four-Dimensional Electron Microscopy
Zewail, A. H. (2010) · Science · doi:10.1126/science.1166135 · Cited by 807
Metadata
- Authors
- Jonge, N. D., Peckys, D. B., Kremers, G. J., & Piston, D. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-02-17
- Volume
- 106
- Issue
- 7
- Pages
- 2159-2164
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2080853943
- Cited by
- 489
- References
- 28
- FWCI
- 17.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.