The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Electron microscopy of whole cells in liquid with nanometer resolution
Open accessAbstract
Single gold-tagged epidermal growth factor (EGF) molecules bound to cellular EGF receptors of fixed fibroblast cells were imaged in liquid with a scanning transmission electron microscope (STEM). The cells were placed in buffer solution in a microfluidic device with electron transparent windows inside the vacuum of the electron microscope. A spatial resolution of 4 nm and a pixel dwell time of 20 μs were obtained. The liquid layer was sufficiently thick to contain the cells with a thickness of 7 ± 1 μm. The experimental findings are consistent with a theoretical calculation. Liquid STEM is a unique approach for imaging single molecules in whole cells with significantly improved resolution and imaging speed over existing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967 · cited 3×
“Likewise, live-cell STED imaging was accomplished at video frequency (a pixel dwell time of 4 s), but at a reduced resolution of 60 nm (32).”
BackgroundMulticolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
STED microscopy reveals that synaptotagmin remains clustered after synaptic vesicle exocytosis
Willig, K. I., Rizzoli, S. O., Westphal, V., Jahn, R., & Hell, S. W. (2006) · Nature · doi:10.1038/nature04592 · Cited by 1,225
Studying protein dynamics in living cells
Lippincott-Schwartz, J., Snapp, E., & Kenworthy, A. (2001) · Nature Reviews Molecular Cell Biology · doi:10.1038/35073068 · Cited by 1,190
Live-cell photoactivated localization microscopy of nanoscale adhesion dynamics
Shroff, H., Galbraith, C. G., Galbraith, J. A., & Betzig, E. (2008) · Nature Methods · doi:10.1038/nmeth.1202 · Cited by 873
Quantum dot ligands provide new insights into erbB/HER receptor–mediated signal transduction
Lidke, D. S., Nagy, P., Heintzmann, R., Arndt-Jovin, D. J., Post, J. N., Grecco, H. E., Jares-Erijman, E. A., & Jovin, T. M. (2004) · Nature Biotechnology · doi:10.1038/nbt929 · Cited by 828
Three-dimensional sub–100 nm resolution fluorescence microscopy of thick samples
Juette, M. F., Gould, T. J., Lessard, M. D., Mlodzianoski, M. J., Nagpure, B. S., Bennett, B. T., Hess, S. T., & Bewersdorf, J. (2008) · Nature Methods · doi:10.1038/nmeth.1211 · Cited by 812
Dynamic microscopy of nanoscale cluster growth at the solid–liquid interface
Williamson, M. J., Tromp, R. M., Vereecken, P. M., Hull, R., & Ross, F. M. (2003) · Nature Materials · doi:10.1038/nmat944 · Cited by 806
Video-Rate Far-Field Optical Nanoscopy Dissects Synaptic Vesicle Movement
Westphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., Jahn, R., & Hell, S. W. (2008) · Science · doi:10.1126/science.1154228 · Cited by 788
Cited by
Observation of Single Colloidal Platinum Nanocrystal Growth Trajectories
Zheng, H., Smith, R. K., Jun, Y.-W., Kisielowski, C., Dahmen, U., & Alivisatos, A. P. (2009) · Science · doi:10.1126/science.1172104 · Cited by 1,337
Ma, X., Geiser-Lee, J., Deng, Y., & Kolmakov, A. (2010) · Science of The Total Environment · doi:10.1016/j.scitotenv.2010.03.031 · Cited by 1,263
Nanotechnology: A New Opportunity in Plant Sciences
Wang, P., Lombi, E., Zhao, F.-J., & Kopittke, P. M. (2016) · Trends in Plant Science · doi:10.1016/j.tplants.2016.04.005 · Cited by 1,062
Electron microscopy of specimens in liquid
de Jonge, N., & Ross, F. M. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.161 · Cited by 952
Four-Dimensional Electron Microscopy
Zewail, A. H. (2010) · Science · doi:10.1126/science.1166135 · Cited by 807
Electron–Water Interactions and Implications for Liquid Cell Electron Microscopy
Schneider, N. M., Norton, M. M., Mendel, B. J., Grogan, J. M., Ross, F. M., & Bau, H. H. (2014) · The Journal of Physical Chemistry C · doi:10.1021/jp507400n · Cited by 654
Opportunities and challenges in liquid cell electron microscopy
Ross, F. M. (2015) · Science · doi:10.1126/science.aaa9886 · Cited by 609
Electrocatalysis in Alkaline Media and Alkaline Membrane-Based Energy Technologies
Yang, Y., Peltier, C. R., Zeng, R., Schimmenti, R., Li, Q., Huang, X., Yan, Z., Potsi, G., Selhorst, R., Lu, X., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00331 · Cited by 544
Sapsford, K. E., Tyner, K. M., Dair, B. J., Deschamps, J. R., & Medintz, I. L. (2011) · Analytical Chemistry · doi:10.1021/ac200853a · Cited by 538
In situ TEM electrochemistry of anode materials in lithium ion batteries
Liu, X. H., & Huang, J. Y. (2011) · Energy & Environmental Science · doi:10.1039/c1ee01918j · Cited by 496
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
Direct in Situ Determination of the Mechanisms Controlling Nanoparticle Nucleation and Growth
Woehl, T. J., Evans, J. E., Arslan, I., Ristenpart, W. D., & Browning, N. D. (2012) · ACS Nano · doi:10.1021/nn303371y · Cited by 439
In vivo degeneration and the fate of inorganic nanoparticles
Feliu, N., Docter, D., Heine, M., del Pino, P., Ashraf, S., Kolosnjaj-Tabi, J., Macchiarini, P., Nielsen, P., Alloyeau, D., Gazeau, F., et al. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00699f · Cited by 423
Wu, K.-J., Tse, E. C. M., Shang, C., & Guo, Z. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100821 · Cited by 400
Atomic-Scale Observations of Catalyst Structures under Reaction Conditions and during Catalysis
Tao, F. (., & Crozier, P. A. (2016) · Chemical Reviews · doi:10.1021/cr5002657 · Cited by 357
Bubble and Pattern Formation in Liquid Induced by an Electron Beam
Grogan, J. M., Schneider, N. M., Ross, F. M., & Bau, H. H. (2014) · Nano Letters · doi:10.1021/nl404169a · Cited by 346
Mehdi, B. L., Qian, J., Nasybulin, E., Park, C., Welch, D. A., Faller, R., Mehta, H., Henderson, W. A., Xu, W., Wang, C. M., et al. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b00175 · Cited by 325
Operando Methods in Electrocatalysis
Yang, Y., Xiong, Y., Zeng, R., Lu, X., Krumov, M., Huang, X., Xu, W., Wang, H., DiSalvo, F. J., Brock, J. D., et al. (2021) · ACS Catalysis · doi:10.1021/acscatal.0c04789 · Cited by 274
The scanning electron microscope in microbiology and diagnosis of infectious disease
Golding, C. G., Lamboo, L. L., Beniac, D. R., & Booth, T. F. (2016) · Scientific Reports · doi:10.1038/srep26516 · Cited by 236
Graphene-enabled electron microscopy and correlated super-resolution microscopy of wet cells
Wojcik, M., Hauser, M., Li, W., Moon, S., & Xu, K. (2015) · Nature Communications · doi:10.1038/ncomms8384 · Cited by 133
Metadata
- Authors
- Jonge, N. D., Peckys, D. B., Kremers, G. J., & Piston, D. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-02-17
- Volume
- 106
- Issue
- 7
- Pages
- 2159-2164
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2080853943
- Cited by
- 489
- References
- 28
- FWCI
- 17.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.