Multilayer three-dimensional super resolution imaging of thick biological samples
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Recent advances in optical microscopy have enabled biological imaging beyond the diffraction limit at nanometer resolution. A general feature of most of the techniques based on photoactivated localization microscopy (PALM) or stochastic optical reconstruction microscopy (STORM) has been the use of thin biological samples in combination with total internal reflection, thus limiting the imaging depth to a fraction of an optical wavelength. However, to study whole cells or organelles that are typically up to 15 μm deep into the cell, the extension of these methods to a three-dimensional (3D) super resolution technique is required. Here, we report an advance in optical microscopy that enables imaging of protein distributions in cells with a lateral localization precision better than 50 nm at multiple imaging planes deep in biological samples. The approach is based on combining the lateral super resolution provided by PALM with two-photon temporal focusing that provides optical sectioning. We have generated super-resolution images over an axial range of ≈10 μm in both mitochondrially labeled fixed cells, and in the membranes of living S2 Drosophila cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488 · cited 1×
“This gives the temporal focusing a depth of field and sectioning capability that is comparable with a confocal or two-photon microscope (18).”
BackgroundImaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772 · cited 4×
“Using other photoactivatable fluorescent proteins (such as EosFP), which emit more photons before bleaching and have a higher contrast ratio (ratio of the fluorescence intensity between the on and the off state), would likely allow a higher localization precision, lower background, and higher resolution (6).”
BackgroundMethodInfluentialSub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078 · cited 4×
“Rust MJ, Bates M, Zhuang X (2006) Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM).”
BackgroundInfluentialCommunication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539 · cited 1×
“The magnification was chosen to satisfy the Nyquist criteria (22), which requires that the sampling frequency be at least twice as high as the highest frequency present in the signal.”
BackgroundCommunication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605 · cited 1×
“This is mainly due to the following: In photoactivated localization microscopy (PALM) (6, 12) and stochastic optical reconstruction microscopy (STORM) (8), a sufficient signal-to-noise ratio is required to discriminate single molecules from the background.”
BackgroundThree-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796 · cited 1×
“I studies, based on defocusing (1), astigmatism (2), and others (3), have extended super resolution imaging (2, 4–13) to three dimensions (3D); however, only up to a few hundred nanometers in depth in biological samples.”
BackgroundOptical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355
Gustafsson, M. G. L., Shao, L., Carlton, P. M., Wang, C. J. R., Golubovskaya, I. N., Cande, W. Z., Agard, D. A., & Sedat, J. W. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120345 · Cited by 1,557
STED microscopy reveals that synaptotagmin remains clustered after synaptic vesicle exocytosis
Willig, K. I., Rizzoli, S. O., Westphal, V., Jahn, R., & Hell, S. W. (2006) · Nature · doi:10.1038/nature04592 · Cited by 1,225
Cited by
Breaking the Diffraction Barrier: Super-Resolution Imaging of Cells
Huang, B., Babcock, H., & Zhuang, X. (2010) · Cell · doi:10.1016/j.cell.2010.12.002 · Cited by 1,156
Pavani, S. R. P., Thompson, M. A., Biteen, J. S., Lord, S. J., Liu, N., Twieg, R. J., Piestun, R., & Moerner, W. E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900245106 · Cited by 1,040
Interferometric fluorescent super-resolution microscopy resolves 3D cellular ultrastructure
Shtengel, G., Galbraith, J. A., Galbraith, C. G., Lippincott-Schwartz, J., Gillette, J. M., Manley, S., Sougrat, R., Waterman, C. M., Kanchanawong, P., Davidson, M. W., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813131106 · Cited by 888
Two-photon absorption properties of fluorescent proteins
Drobizhev, M., Makarov, N. S., Tillo, S. E., Hughes, T. E., & Rebane, A. (2011) · Nature Methods · doi:10.1038/nmeth.1596 · Cited by 675
Superresolution Imaging using Single-Molecule Localization
Patterson, G., Davidson, M., Manley, S., & Lippincott-Schwartz, J. (2010) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103444 · Cited by 527
von Diezmann, L., Shechtman, Y., & Moerner, W. E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00629 · Cited by 491
Compressive fluorescence microscopy for biological and hyperspectral imaging
Studer, V., Bobin, J., Chahid, M., Mousavi, H. S., Candes, E., & Dahan, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1119511109 · Cited by 411
Live-cell 3D super-resolution imaging in thick biological samples
Cella Zanacchi, F., Lavagnino, Z., Perrone Donnorso, M., Del Bue, A., Furia, L., Faretta, M., & Diaspro, A. (2011) · Nature Methods · doi:10.1038/nmeth.1744 · Cited by 385
Brain-wide 3D imaging of neuronal activity in Caenorhabditis elegans with sculpted light
Schrödel, T., Prevedel, R., Aumayr, K., Zimmer, M., & Vaziri, A. (2013) · Nature Methods · doi:10.1038/nmeth.2637 · Cited by 333
Self-citationExcited state reactions in fluorescent proteins
Meech, S. R. (2009) · Chemical Society Reviews · doi:10.1039/b820168b · Cited by 325
Photoactivatable fluorescent proteins for diffraction-limited and super-resolution imaging
Lippincott-Schwartz, J., & Patterson, G. H. (2009) · Trends in Cell Biology · doi:10.1016/j.tcb.2009.09.003 · Cited by 316
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
High-density three-dimensional localization microscopy across large volumes
Legant, W. R., Shao, L., Grimm, J. B., Brown, T. A., Milkie, D. E., Avants, B. B., Lavis, L. D., & Betzig, E. (2016) · Nature Methods · doi:10.1038/nmeth.3797 · Cited by 288
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Brown, T. A., Tkachuk, A. N., Shtengel, G., Kopek, B. G., Bogenhagen, D. F., Hess, H. F., & Clayton, D. A. (2011) · Molecular and Cellular Biology · doi:10.1128/mcb.05694-11 · Cited by 250
York, A. G., Ghitani, A., Vaziri, A., Davidson, M. W., & Shroff, H. (2011) · Nature Methods · doi:10.1038/nmeth.1571 · Cited by 172
Self-citationFluorescence microscopy—A historical and technical perspective
Renz, M. (2013) · Cytometry Part A · doi:10.1002/cyto.a.22295 · Cited by 165
Seeing beyond the limit: A guide to choosing the right super-resolution microscopy technique
Valli, J., Garcia-Burgos, A., Rooney, L. M., Vale de Melo e Oliveira, B., Duncan, R. R., & Rickman, C. (2021) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2021.100791 · Cited by 159
Metadata
- Authors
- Vaziri, A., Tang, J., Shroff, H., & Shank, C. V.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-12-23
- Volume
- 105
- Issue
- 51
- Pages
- 20221-20226
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2005235042
- Cited by
- 180
- References
- 25
- FWCI
- 9.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.