Adaptive aberration correction in a confocal microscope
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The main advantage of confocal microscopes over their conventional counterparts is their ability to optically “section” thick specimens; the thin image slices thus obtained can be used to reconstruct three-dimensional images, a capability which is particularly useful in biological applications. However, it is well known that the resolution and optical sectioning ability can be severely degraded by system or specimen-induced aberrations. The use of high aperture lenses further exacerbates the problem. Moreover, aberrations can considerably reduce the number of photons that reach the detector, leading to lower contrast. It is rather unfortunate, therefore, that in practical microscopy, aberration-free confocal imaging is rarely achieved. Adaptive optics systems, which have been used widely to correct aberrations in astronomy, offer a solution here but also present new challenges. The optical system and the source of aberrations in a confocal microscope are considerably different and require a novel approach to wavefront sensing. This method, based upon direct measurement of Zernike aberration modes, also exhibits an axial selectivity similar to that of a confocal microscope. We demonstrate an adaptive confocal fluorescence microscope incorporating this modal sensor together with a deformable membrane mirror for aberration correction. Aberration corrected images of biological specimens show considerable improvement in contrast and apparent restoration of axial resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Handbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Adaptive Optics for Astronomical Telescopes
Hardy, J. W. (1998) · doi:10.1093/oso/9780195090192.001.0001 · Cited by 1,009
Tyson, R. K. (2015) · CRC Press eBooks · doi:10.1201/b19712 · Cited by 864
Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index
HELL, S., REINER, G., CREMER, C., & STELZER, E. H. K. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03315.x · Cited by 640
Aberration correction for confocal imaging in refractive‐index‐mismatched media
Booth, M. J., Neil, M. A. A., & Wilson, T. (1998) · Journal of Microscopy · doi:10.1111/j.1365-2818.1998.99999.x · Cited by 248
Self-citationNew modal wave-front sensor: a theoretical analysis
Neil, M. A. A., Booth, M. J., & Wilson, T. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.001098 · Cited by 203
Self-citationComputational adaptive optics for live three-dimensional biological imaging
Kam, Z., Hanser, B. M., Gustafsson, M. G. L., Agard, D. A., & Sedat, J. W. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.071275698 · Cited by 110
Closed-loop aberration correction by use of a modal Zernike wave-front sensor
Neil, M. A. A., Booth, M. J., & Wilson, T. (2000) · Optics Letters · doi:10.1364/ol.25.001083 · Cited by 93
Self-citation
Cited by
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
A guide to super-resolution fluorescence microscopy
Schermelleh, L., Heintzmann, R., & Leonhardt, H. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201002018 · Cited by 1,255
Light Microscopy Techniques for Live Cell Imaging
Stephens, D. J., & Allan, V. J. (2003) · Science · doi:10.1126/science.1082160 · Cited by 1,179
Choi, W., Fang-Yen, C., Badizadegan, K., Oh, S., Lue, N., Dasari, R. R., & Feld, M. S. (2007) · Nature Methods · doi:10.1038/nmeth1078 · Cited by 955
Guidestar-assisted wavefront-shaping methods for focusing light into biological tissue
Horstmeyer, R., Ruan, H., & Yang, C. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.140 · Cited by 651
Adaptive optics via pupil segmentation for high-resolution imaging in biological tissues
Ji, N., Milkie, D. E., & Betzig, E. (2010) · Nature Methods · doi:10.1038/nmeth.1411 · Cited by 585
Advances in multiphoton microscopy technology
Hoover, E. E., & Squier, J. A. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.361 · Cited by 542
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
In situ wavefront correction and its application to micromanipulation
Čižmár, T., Mazilu, M., & Dholakia, K. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.85 · Cited by 452
Two-Photon Photopolymerization and 3D Lithographic Microfabrication
Sun, H.-B., & Kawata, S. (2006) · Advances in Polymer Science · doi:10.1007/b94405 · Cited by 380
Adaptive optics enables 3D STED microscopy in aberrating specimens
Gould, T. J., Burke, D., Bewersdorf, J., & Booth, M. J. (2012) · Optics Express · doi:10.1364/oe.20.020998 · Cited by 315
Self-citationTwo-photon excitation microscopy for the study of living cells and tissues
Benninger, R. K. P., & Piston, D. W. (2013) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0411s59 · Cited by 311
Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing
Rueckel, M., Mack-Bucher, J. A., & Denk, W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604791103 · Cited by 307
Cahalan, M. D., & Parker, I. (2008) · Annual Review of Immunology · doi:10.1146/annurev.immunol.24.021605.090620 · Cited by 302
Adaptive optics for high-resolution imaging
Hampson, K. M., Turcotte, R., Miller, D. T., Kurokawa, K., Males, J. R., Ji, N., & Booth, M. J. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00066-7 · Cited by 291
Self-citationVisualization of skin penetration using confocal laser scanning microscopy
Alvarez-Román, R., Naik, A., Kalia, Y. N., Fessi, H., & Guy, R. H. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.027 · Cited by 278
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Metasurfaces for biomedical applications: imaging and sensing from a nanophotonics perspective
Zhang, S., Wong, C. L., Zeng, S., Bi, R., Tai, K., Dholakia, K., & Olivo, M. (2020) · Nanophotonics · doi:10.1515/nanoph-2020-0373 · Cited by 270
Adaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
Nanoscopy of living brain slices with low light levels
Testa, I., Urban, N. T., Jakobs, S., Eggeling, C., Willig, K. I., & Hell, S. W. (2012) · Neuron · doi:10.1016/j.neuron.2012.07.028 · Cited by 131
A stochastic view of lymphocyte motility and trafficking within the lymph node
Wei, S. H., Parker, I., Miller, M. J., & Cahalan, M. D. (2003) · Immunological Reviews · doi:10.1034/j.1600-065x.2003.00076.x · Cited by 117
Deep learning-driven adaptive optics for single-molecule localization microscopy
Zhang, P., Ma, D., Cheng, X., Tsai, A. P., Tang, Y., Gao, H.-C., Fang, L., Bi, C., Landreth, G. E., Chubykin, A. A., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-02029-0 · Cited by 42
Metadata
- Authors
- Booth, M. J., Neil, M. A. A., Juškaitis, R., & Wilson, T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-04-16
- Volume
- 99
- Issue
- 9
- Pages
- 5788-5792
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1989752411
- Cited by
- 418
- References
- 12
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.