Nanoparticle-based bio-barcode assay redefines “undetectable” PSA and biochemical recurrence after radical prostatectomy
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
We report the development of a previously undescribed gold nanoparticle bio-barcode assay probe for the detection of prostate specific antigen (PSA) at 330 fg/mL, automation of the assay, and the results of a clinical pilot study designed to assess the ability of the assay to detect PSA in the serum of 18 men who have undergone radical prostatectomy for prostate cancer. Due to a lack of sensitivity, available PSA immunoassays are often not capable of detecting PSA in the serum of men after radical prostatectomy. This new bio-barcode PSA assay is ≈300 times more sensitive than commercial immunoassays. Significantly, with the barcode assay, every patient in this cohort had a measurable serum PSA level after radical prostatectomy. Patients were separated into categories based on PSA levels as a function of time. One group of patients showed low levels of PSA with no significant increase with time and did not recur. Others showed, at some point postprostatectomy, rising PSA levels. The majority recurred. Therefore, this new ultrasensitive assay points to significant possible outcomes: ( i ) The ability to tell patients, who have undetectable PSA levels with conventional assays, but detectable and nonrising levels with the barcode assay, that their cancer will not recur. ( ii ) The ability to assign recurrence earlier because of the ability to measure increasing levels of PSA before conventional tools can make such assignments. ( iii ) The ability to use PSA levels that are not detectable with conventional assays to follow the response of patients to adjuvant or salvage therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SEER Cancer Statistics Review, 1975-2003
Ries, L. A. G., Harkins, D., Krapcho, M. F., Mariotto, A. B., Miller, B., Feuer, E. J., Clegg, L. X., Eisner, M. P., Horner, M., Howlader, N., et al. (2006) · Digital Archive @ GSU · Cited by 11,791
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Self-citationScreening and Prostate-Cancer Mortality in a Randomized European Study
Schröder, F. H., Hugosson, J., Roobol, M. J., Tammela, T. L. J., Ciatto, S., Nelen, V., Kwiatkowski, M., Lujan, M., Lilja, H., Zappa, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810084 · Cited by 4,014
Natural History of Progression After PSA Elevation Following Radical Prostatectomy
Pound, C. R. (1999) · JAMA · doi:10.1001/jama.281.17.1591 · Cited by 3,071
Mortality Results from a Randomized Prostate-Cancer Screening Trial
Andriole, G. L., Crawford, E. D., Grubb, R. L., Buys, S. S., Chia, D., Church, T. R., Fouad, M. N., Gelmann, E. P., Kvale, P. A., Reding, D. J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810696 · Cited by 2,906
SEER Cancer Statistics Review, 1975-2008, National Cancer Institute, Bethesda, MD
Howlader, N. (2011) · Medical Entomology and Zoology · Cited by 2,612
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
Self-citationNanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Self-citationNanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,035
Self-citationThompson, I. M., Tangen, C. M., Paradelo, J., Lucia, M. S., Miller, G., Troyer, D., Messing, E., Forman, J., Chin, J., Swanson, G., et al. (2009) · Journal of Urology · doi:10.1016/j.juro.2008.11.032 · Cited by 1,227
Han, M., Partin, A. W., Pound, C. R., Epstein, J. I., & Walsh, P. C. (2001) · Urologic Clinics of North America · doi:10.1016/s0094-0143(05)70163-4 · Cited by 1,028
Georganopoulou, D. G., Chang, L., Nam, J.-M., Thaxton, C. S., Mufson, E. J., Klein, W. L., & Mirkin, C. A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409336102 · Cited by 835 · cited 7×
“18438 www.pnas.org cgi doi 10.1073 pnas.0904719106 Thaxton et al. provides consistent barcode loading to Au-NPs.”
InfluentialSelf-citationTrock, B. J. (2008) · JAMA · doi:10.1001/jama.299.23.2760 · Cited by 657
Patient-re ported complications and follow-up treatment after radical prostatectomy
Fowler, F. J., Barry, M. J., Lu-yao, G., Roman, A., Wasson, J., & Wennberg, J. E. (1993) · Urology · doi:10.1016/0090-4295(93)90524-e · Cited by 627
Human Anti-Animal Antibody Interferences in Immunological Assays
Kricka, L. J. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.942 · Cited by 586
Storhoff, J. J., Lucas, A. D., Garimella, V., Bao, Y. P., & Müller, U. R. (2004) · Nature Biotechnology · doi:10.1038/nbt977 · Cited by 546
5-Year Tumor Recurrence Rates After Anatomical Radical Retropubic Prostatectomy For Prostate Cancer
Catalona, W. J., & Smith, D. S. (1994) · Journal of Urology · doi:10.1016/s0022-5347(17)32397-2 · Cited by 502
Multiplexed Detection of Protein Cancer Markers with Biobarcoded Nanoparticle Probes
Stoeva, S. I., Lee, J.-S., Smith, J. E., Rosen, S. T., & Mirkin, C. A. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0613106 · Cited by 419
Self-citationStorhoff, J. J., Marla, S. S., Bao, P., Hagenow, S., Mehta, H., Lucas, A., Garimella, V., Patno, T., Buckingham, W., Cork, W., et al. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.08.014 · Cited by 266
Follow-up Prostate Cancer Treatments After Radical Prostatectomy: a Population-Based Study
Lu-Yao, G. L., Potosky, A. L., Albertsen, P. C., Wasson, J. H., Barry, M. J., & Wennberg, J. E. (1996) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/88.3-4.166 · Cited by 196
NONPROSTATIC SOURCES OF PROSTATE-SPECIFIC ANTIGEN
Diamandis, E. P., & Yu, H. (1997) · Urologic Clinics of North America · doi:10.1016/s0094-0143(05)70373-6 · Cited by 172 · cited 1×
“The source of low-level and nonrising PSA in the serum of these patients is uncertain (2, 33).”
BackgroundDetection of Protein Analytes via Nanoparticle-Based Bio Bar Code Technology
Bao, Y. P., Wei, T.-F., Lefebvre, P., An, H., He, L., Kunkel, G. T., & Müller, U. R. (2006) · Analytical Chemistry · doi:10.1021/ac051798d · Cited by 149
Bartsch, G. C., Horninger, W., Klocker, H., Pelzer, A. E., Bektić, J., Oberaigner, W., Schennach, H., Schäfer, G., Frauscher, F., Boniol, M., et al. (2008) · British Journal of Urology · doi:10.1111/j.1464-410x.2008.07502.x · Cited by 141
Self-citationColorimetric Bio-Barcode Amplification Assay for Cytokines
Nam, J., Wise, A. R., & Groves, J. T. (2005) · Analytical Chemistry · doi:10.1021/ac0513764 · Cited by 125
Prostate specific antigen in breast cancer, benign breast disease and normal breast tissue
Yu, H., Diamandis, E. P., Levesque, M., Giai, M., Roagna, R., Ponzone, R., Sismondi, P., Monne, M., & Croce, C. M. (1996) · Breast Cancer Research and Treatment · doi:10.1007/bf01806212 · Cited by 106 · cited 1×
“Human female serum can contain PSA when interrogated with an ultrasensitive PSA immunoassay (24).”
BackgroundProstate Specific Antigen Recurrence After Definitive Therapy
Freedland, S. J., & Moul, J. W. (2007) · The Journal of Urology · doi:10.1016/j.juro.2007.01.137 · Cited by 91
Multifunctional Polymeric Nanoparticles from Diverse Bioactive Agents
Bertin, P. A., Gibbs, J. M., Shen, C. K.-F., Thaxton, C. S., Russin, W. A., Mirkin, C. A., & Nguyen, S. T. (2006) · Journal of the American Chemical Society · doi:10.1021/ja056378k · Cited by 90
Self-citationA Covalent Lock for Self-Assembled Oligonucleotide Conjugates
Herrlein, M., Nelson, J., & Letsinger, R. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00145a042 · Cited by 58
Yeo, K.-T. J., Storm, C. A., Li, Y., Jayne, J. E., Brough, T. J., Quinn-Hall, K. S., & Fitzmaurice, T. F. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00260-0 · Cited by 42
Nakamura, M., Hasumi, H., Miyoshi, Y., et al. (2005) · International Journal of Urology · doi:10.1111/j.1442-2042.2005.01202.x · Cited by 21
How Sensitive Is a Prostate-Specific Antigen Measurement?: How Sensitive Does It Need to Be?
Bock, J. L., & Klee, G. G. (2004) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2004-128-341-hsiapa · Cited by 20
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
Gold nanoparticles: preparation, properties, and applications in bionanotechnology
Yeh, Y.-C., Creran, B., & Rotello, V. M. (2012) · Nanoscale · doi:10.1039/c1nr11188d · Cited by 1,346
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Metadata
- Authors
- Thaxton, C. S., Elghanian, R., Thomas, A. D., Stoeva, S. I., Lee, J.-S., Smith, N. D., Schaeffer, A. J., Klocker, H., Horninger, W., Bartsch, G., & Mirkin, C. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-11-03
- Volume
- 106
- Issue
- 44
- Pages
- 18437-18442
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2145363935
- Cited by
- 388
- References
- 31
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.