Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
We propose a unique method for cell sorting, “Ephesia,” using columns of biofunctionalized superparamagnetic beads self-assembled in a microfluidic channel onto an array of magnetic traps prepared by microcontact printing. It combines the advantages of microfluidic cell sorting, notably the application of a well controlled, flow-activated interaction between cells and beads, and those of immunomagnetic sorting, notably the use of batch-prepared, well characterized antibody-bearing beads. On cell lines mixtures, we demonstrated a capture yield better than 94%, and the possibility to cultivate in situ the captured cells. A second series of experiments involved clinical samples—blood, pleural effusion, and fine needle aspirates— issued from healthy donors and patients with B-cell hematological malignant tumors (leukemia and lymphoma). The immunophenotype and morphology of B-lymphocytes were analyzed directly in the microfluidic chamber, and compared with conventional flow cytometry and visual cytology data, in a blind test. Immunophenotyping results using Ephesia were fully consistent with those obtained by flow cytometry. We obtained in situ high resolution confocal three-dimensional images of the cell nuclei, showing intranuclear details consistent with conventional cytological staining. Ephesia thus provides a powerful approach to cell capture and typing allowing fully automated high resolution and quantitative immunophenotyping and morphological analysis. It requires at least 10 times smaller sample volume and cell numbers than cytometry, potentially increasing the range of indications and the success rate of microbiopsy-based diagnosis, and reducing analysis time and cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WHO Classification of Tumours of Haematopoietic and Lymphoid Tissues
Swerdlow, S. H. (2017) · Medical Entomology and Zoology · Cited by 12,933
Bonnet, D., & Dick, J. E. (1997) · Nature Medicine · doi:10.1038/nm0797-730 · Cited by 5,864
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Force mapping in epithelial cell migration
du Roure, O., Saez, A., Buguin, A., Austin, R. H., Chavrier, P., Siberzan, P., & Ladoux, B. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408482102 · Cited by 779
Detection and characterization of carcinoma cells in the blood
Racila, E., Euhus, D., Weiss, A. J., Rao, C., McConnell, J., Terstappen, L. W. M. M., & Uhr, J. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4589 · Cited by 712
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Stott, S. L., Lee, R. J., Nagrath, S., Yu, M., Miyamoto, D. T., Ulkus, L., Inserra, E. J., Ulman, M., Springer, S., Nakamura, Z., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000403 · Cited by 539
Self-Assembled Magnetic Matrices for DNA Separation Chips
Doyle, P. S., Bibette, J., Bancaud, A., & Viovy, J. (2002) · Science · doi:10.1126/science.1068420 · Cited by 520
Self-citationOptimal Spatial Adaptation for Patch-Based Image Denoising
Kervrann, C., & Boulanger, J. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.877529 · Cited by 431
B1 cells: similarities and differences with other B cell subsets
Martin, F., & Kearney, J. F. (2001) · Current Opinion in Immunology · doi:10.1016/s0952-7915(00)00204-1 · Cited by 393
Multitarget magnetic activated cell sorter
Adams, J. D., Kim, U., & Soh, H. T. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0809795105 · Cited by 390
Continuous microfluidic immunomagnetic cell separation
Inglis, D. W., Riehn, R., Austin, R. H., & Sturm, J. C. (2004) · Applied Physics Letters · doi:10.1063/1.1823015 · Cited by 353
A microfluidic device for practical label-free CD4+ T cell counting of HIV-infected subjects
Cheng, X., Irimia, D., Dixon, M., Sekine, K., Demirci, U., Zamir, L., Tompkins, R. G., Rodriguez, W., & Toner, M. (2007) · Lab Chip · doi:10.1039/b612966h · Cited by 340
Trastuzumab in the Treatment of Breast Cancer
Hortobagyi, G. N. (2005) · New England Journal of Medicine · doi:10.1056/nejme058196 · Cited by 306
Pachmann, K., Camara, O., Kavallaris, A., Krauspe, S., Malarski, N., Gajda, M., Kroll, T., Jörke, C., Hammer, U., Altendorf-Hofmann, A., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.13.6523 · Cited by 280
Field-Induced Structures in Ferrofluid Emulsions
Liu, J., Lawrence, E. M., Wu, A., Ivey, M. L., Flores, G. A., Javier, K., Bibette, J., & Richard, J. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.2828 · Cited by 271
Pierga, J.-Y., Bonneton, C., Vincent-Salomon, A., de Cremoux, P., Nos, C., Blin, N., Pouillart, P., Thiery, J.-P., & Magdelénat, H. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-0102-03 · Cited by 223
Self-citationDiagnosis and Subclassification of Primary and Recurrent Lymphoma
Meda, B. A., Buss, D. H., Woodruff, R. D., Cappellari, J. O., Rainer, R. O., Powell, B. L., & R.Geisinger, K. (2000) · American Journal of Clinical Pathology · doi:10.1309/0q7f-qtgm-6dpd-tlgy · Cited by 216
Rapid detection and profiling of cancer cells in fine-needle aspirates
Lee, H., Yoon, T.-J., Figueiredo, J.-L., Swirski, F. K., & Weissleder, R. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902365106 · Cited by 187
Biomimetic technique for adhesion-based collection and separation of cells in a microfluidic channel
Chang, W. C., Lee, L. P., & Liepmann, D. (2005) · Lab on a Chip · doi:10.1039/b400455h · Cited by 166
Das, D. K. (1999) · Diagnostic Cytopathology · doi:10.1002/(sici)1097-0339(199910)21:4<240::aid-dc3>3.0.co;2-z · Cited by 115
Morton, K. J., Loutherback, K., Inglis, D. W., Tsui, O. K. C., Sturm, J. C., Chou, S. Y., & Austin, R. H. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0712398105 · Cited by 113
A new non-Hodgkin's B-cell line (DoHH2) with a chromosomal translocation t(14;18)(q32;q21).
Kluin‐Nelemans, H. C., Limpens, J., Meerabux, J., Beverstock, G. C., Jansen, J. H., de Jong, D., & Kluin, P. M. (1991) · PubMed · Cited by 97
Practical Principles of Cytopathology
DeMay, R. M. (1999) · Cited by 27
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Single-cell RNA-seq: advances and future challenges
Saliba, A.-E., Westermann, A. J., Gorski, S. A., & Vogel, J. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku555 · Cited by 847
“Another relevant limitation of FACS is the requirement of a large starting volume, which hampers the isolation of cells from extremely low volume samples (containing a few microliters) such as fine-needle aspirates (54).”
Self-citationIsolation and retrieval of circulating tumor cells using centrifugal forces
Hou, H. W., Warkiani, M. E., Khoo, B. L., Li, Z. R., Soo, R. A., Tan, D. S.-W., Lim, W.-T., Han, J., Bhagat, A. A. S., & Lim, C. T. (2013) · Scientific Reports · doi:10.1038/srep01259 · Cited by 736
Aptamer-Based Detection of Circulating Targets for Precision Medicine
Wu, L., Wang, Y., Xu, X., Liu, Y., Lin, B., Zhang, M., Zhang, J., Wan, S., Yang, C., & Tan, W. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01140 · Cited by 705
Metadata
- Authors
- Saliba, A.-E., Saias, L., Psychari, E., Minc, N., Simon, D., Bidard, F.-C., Mathiot, C., Pierga, J.-Y., Fraisier, V., Salamero, J., Saada, V., Farace, F., Vielh, P., Malaquin, L., & Viovy, J.-L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-08-02
- Volume
- 107
- Issue
- 33
- Pages
- 14524-14529
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2019253887
- Cited by
- 337
- References
- 30
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.