Bleaching/blinking assisted localization microscopy for superresolution imaging using standard fluorescent molecules
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Superresolution imaging techniques based on the precise localization of single molecules, such as photoactivated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM), achieve high resolution by fitting images of single fluorescent molecules with a theoretical Gaussian to localize them with a precision on the order of tens of nanometers. PALM/STORM rely on photoactivated proteins or photoswitching dyes, respectively, which makes them technically challenging. We present a simple and practical way of producing point localization-based superresolution images that does not require photoactivatable or photoswitching probes. Called bleaching/blinking assisted localization microscopy (BaLM), the technique relies on the intrinsic bleaching and blinking behaviors characteristic of all commonly used fluorescent probes. To detect single fluorophores, we simply acquire a stream of fluorescence images. Fluorophore bleach or blink-off events are detected by subtracting from each image of the series the subsequent image. Similarly, blink-on events are detected by subtracting from each frame the previous one. After image subtractions, fluorescence emission signals from single fluorophores are identified and the localizations are determined by fitting the fluorescence intensity distribution with a theoretical Gaussian. We also show that BaLM works with a spectrum of fluorescent molecules in the same sample. Thus, BaLM extends single molecule-based superresolution localization to samples labeled with multiple conventional fluorescent probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772 · cited 9×
“Our measurements for the precision of an Alexa dye with BaLM is ≈50 nm, which is significantly less than the precision reported for PALM/STORM (≈10–20 nm) (8, 9).”
BackgroundMethodResultInfluentialSelf-citationSub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078 · cited 4×
“Our measurements for the precision of an Alexa dye with BaLM is ≈50 nm, which is significantly less than the precision reported for PALM/STORM (≈10–20 nm) (8, 9).”
BackgroundMethodInfluentialThree-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796 · cited 1×
“Furthermore, BaLM in principle can be adapted to produce 3D localization by using a similar approach to that developed for 3D STORM (12, 32).”
MethodPrecise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320 · cited 2×
“cision of localization were performed in a similar manner as described (8, 22).”
BackgroundMethodCaveolin, a protein component of caveolae membrane coats
Rothberg, K. G., Heuser, J. E., Donzell, W. C., Ying, Y.-S., Glenney, J. R., & Anderson, R. G. W. (1992) · Cell · doi:10.1016/0092-8674(92)90143-z · Cited by 2,258
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866 · cited 1×
“For example, direct STORM (dSTORM) takes advantage of the ability to switch Cy5 or Alexa Fluor 647 with a cycle of green and red laser light (11).”
BackgroundMulticolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504 · cited 4×
“Properties of fluorophores such as brightness, quantum yield, and photostability, vary widely (10, 34, 35).”
BackgroundMethodInfluentialFluorescent probes for super-resolution imaging in living cells
Fernández-Suárez, M., & Ting, A. Y. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2531 · Cited by 1,306 · cited 1×
“This range was determined based on previously reported measurements of photon counts of Alexa dyes (23), as well as examination of the photon counts of single molecules at the end of bleaching acquisitions in our experiments (Materials and Methods).”
MethodBreaking the Diffraction Barrier: Super-Resolution Imaging of Cells
Huang, B., Babcock, H., & Zhuang, X. (2010) · Cell · doi:10.1016/j.cell.2010.12.002 · Cited by 1,156
Cited by
Deep learning massively accelerates super-resolution localization microscopy
Ouyang, W., Aristov, A., Lelek, M., Hao, X., & Zimmer, C. (2018) · Nature Biotechnology · doi:10.1038/nbt.4106 · Cited by 570
Shim, S.-H., Xia, C., Zhong, G., Babcock, H. P., Vaughan, J. C., Huang, B., Wang, X., Xu, C., Bi, G.-Q., & Zhuang, X. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201882109 · Cited by 514
Application of semiconductor quantum dots in bioimaging and biosensing
Martynenko, I. V., Litvin, A. P., Purcell-Milton, F., Baranov, A. V., Fedorov, A. V., & Gun'ko, Y. K. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01425b · Cited by 382
Fluorescent proteins for live-cell imaging with super-resolution
Nienhaus, K., & Ulrich Nienhaus, G. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60171d · Cited by 337
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Photoinduced Chemistry in Fluorescent Proteins: Curse or Blessing?
Acharya, A., Bogdanov, A. M., Grigorenko, B. L., Bravaya, K. B., Nemukhin, A. V., Lukyanov, K. A., & Krylov, A. I. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00238 · Cited by 269
Plant lipids: Key players of plasma membrane organization and function
Mamode Cassim, A., Gouguet, P., Gronnier, J., Laurent, N., Germain, V., Grison, M., Boutté, Y., Gerbeau-Pissot, P., Simon-Plas, F., & Mongrand, S. (2019) · Progress in Lipid Research · doi:10.1016/j.plipres.2018.11.002 · Cited by 266
Structural organization of nuclear lamins A, C, B1, and B2 revealed by superresolution microscopy
Shimi, T., Kittisopikul, M., Tran, J., Goldman, A. E., Adam, S. A., Zheng, Y., Jaqaman, K., & Goldman, R. D. (2015) · Molecular Biology of the Cell · doi:10.1091/mbc.e15-07-0461 · Cited by 252
“Color shifts in the x-, y-, and z-axes were corrected using MEFs into which TetraSpeck Fluorescent Microspheres (diameter 0.1 μm; Life Technologies) had been incorporated as described previously (Burnette et al., 2011).”
MethodInfluentialBaddeley, D., & Bewersdorf, J. (2018) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-060815-014801 · Cited by 186
Single-molecule techniques in biophysics: a review of the progress in methods and applications
Miller, H., Zhou, Z., Shepherd, J., Wollman, A. J. M., & Leake, M. C. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aa8a02 · Cited by 184
“microscopy (BaLM) [88] can be more simple to implement as only one illumination wavelength is required and images are acquired continuously”
BackgroundRed Fluorescent Proteins: Advanced Imaging Applications and Future Design
Shcherbakova, D. M., Subach, O. M., & Verkhusha, V. V. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200408 · Cited by 174
Metadata
- Authors
- Burnette, D. T., Sengupta, P., Dai, Y., Lippincott-Schwartz, J., & Kachar, B.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-12-13
- Volume
- 108
- Issue
- 52
- Pages
- 21081-21086
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2162360553
- Cited by
- 211
- References
- 40
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.