Shaping acoustic fields as a toolset for microfluidic manipulations in diagnostic technologies
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Ultrasonics offers the possibility of developing sophisticated fluid manipulation tools in lab-on-a-chip technologies. Here we demonstrate the ability to shape ultrasonic fields by using phononic lattices, patterned on a disposable chip, to carry out the complex sequence of fluidic manipulations required to detect the rodent malaria parasite Plasmodium berghei in blood. To illustrate the different tools that are available to us, we used acoustic fields to produce the required rotational vortices that mechanically lyse both the red blood cells and the parasitic cells present in a drop of blood. This procedure was followed by the amplification of parasitic genomic sequences using different acoustic fields and frequencies to heat the sample and perform a real-time PCR amplification. The system does not require the use of lytic reagents nor enrichment steps, making it suitable for further integration into lab-on-a-chip point-of-care devices. This acoustic sample preparation and PCR enables us to detect ca. 30 parasites in a microliter-sized blood sample, which is the same order of magnitude in sensitivity as lab-based PCR tests. Unlike other lab-on-a-chip methods, where the sample moves through channels, here we use our ability to shape the acoustic fields in a frequency-dependent manner to provide different analytical functions. The methods also provide a clear route toward the integration of PCR to detect pathogens in a single handheld system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Weltgesundheitsorganisation (2005) · Cited by 3,799
Inhibition and facilitation of nucleic acid amplification
Wilson, I. G. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.10.3741-3751.1997 · Cited by 2,266 · cited 1×
“These may include the use of lytic agents, enzymes, or detergents, which can inhibit subsequent analysis and have to be removed (11), most usually using centrifugation before further processing.”
BackgroundMicrofluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979 · cited 1×
“Implementing such techniques has however been a particular difficulty in developing a fully integrated sample-to-answer solution for molecular diagnostics (20).”
BackgroundRapid Diagnostic Tests for Malaria Parasites
Moody, A. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.1.66-78.2002 · Cited by 1,418 · cited 2×
“0001% or 1 parasite∕μL of blood (30)] and better than routine smear diagnostic [500 parasite∕μL (30)] and rapid tests [>1;000∕μL (29)] and corresponded to a 1 day incubation after mouse infection.”
BackgroundResultPoint-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Microscale acoustofluidics: Microfluidics driven via acoustics and ultrasonics
Friend, J., & Yeo, L. Y. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.647 · Cited by 964 · cited 1×
“[0, 1].”
Ultrafast microfluidics using surface acoustic waves
Yeo, L. Y., & Friend, J. R. (2009) · Biomicrofluidics · doi:10.1063/1.3056040 · Cited by 391 · cited 2×
“and the surface tensions at the droplet pinning contact line, different wave amplitudes give rise to different phenomena (3), from streaming at low powers to movement, jetting, and nebulization at high power.”
BackgroundSurface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices
Franke, T., Abate, A. R., Weitz, D. A., & Wixforth, A. (2009) · Lab on a Chip · doi:10.1039/b906819h · Cited by 369
Surface acoustic wave actuated cell sorting (SAWACS)
Franke, T., Braunmüller, S., Schmid, L., Wixforth, A., & Weitz, D. A. (2010) · Lab on a Chip · doi:10.1039/b915522h · Cited by 363 · cited 1×
“Although only these two functions are combined here, the use of phononic lattices opens a wide range of applications and could be used to combine other SAWactuated techniques, such as the direction of drops for highthroughput analysis (21, 22) or nebulization (7).”
Background
Cited by
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Acoustic tweezers for the life sciences
Ozcelik, A., Rufo, J., Guo, F., Gu, Y., Li, P., Lata, J., & Huang, T. J. (2018) · Nature Methods · doi:10.1038/s41592-018-0222-9 · Cited by 826
Two-dimensional single-cell patterning with one cell per well driven by surface acoustic waves
Collins, D. J., Morahan, B., Garcia-Bustos, J., Doerig, C., Plebanski, M., & Neild, A. (2015) · Nature Communications · doi:10.1038/ncomms9686 · Cited by 588
Surface Acoustic Wave Microfluidics
Yeo, L. Y., & Friend, J. R. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141418 · Cited by 561
A Review on Macroscale and Microscale Cell Lysis Methods
Shehadul Islam, M., Aryasomayajula, A., & Selvaganapathy, P. (2017) · Micromachines · doi:10.3390/mi8030083 · Cited by 541
Immune Cell Membrane‐Coated Biomimetic Nanoparticles for Targeted Cancer Therapy
Oroojalian, F., Beygi, M., Baradaran, B., Mokhtarzadeh, A., & Shahbazi, M. (2021) · Small · doi:10.1002/smll.202006484 · Cited by 528
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, M. L., Mach, K. E., Wong, P. K., & Liao, J. C. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.888313 · Cited by 435
Zhang, P., Bachman, H., Ozcelik, A., & Huang, T. J. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-090919-102205 · Cited by 316
Advances in digital polymerase chain reaction (dPCR) and its emerging biomedical applications
Cao, L., Cui, X., Hu, J., Li, Z., Choi, J. R., Yang, Q., Lin, M., Ying Hui, L., & Xu, F. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.082 · Cited by 291
Sorting drops and cells with acoustics: acoustic microfluidic fluorescence-activated cell sorter
Schmid, L., Weitz, D. A., & Franke, T. (2014) · Lab Chip · doi:10.1039/c4lc00588k · Cited by 271
Digital acoustofluidics enables contactless and programmable liquid handling
Zhang, S. P., Lata, J., Chen, C., Mai, J., Guo, F., Tian, Z., Ren, L., Mao, Z., Huang, P.-H., Li, P., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-05297-z · Cited by 207
Taller, D., Richards, K., Slouka, Z., Senapati, S., Hill, R., Go, D. B., & Chang, H.-C. (2015) · Lab on a Chip · doi:10.1039/c5lc00036j · Cited by 195
Collins, D. J., Neild, A., & Ai, Y. (2016) · Lab on a Chip · doi:10.1039/c5lc01335f · Cited by 190
Microfluidic technologies for circulating tumor cell isolation
Cho, H., Kim, J., Song, H., Sohn, K. Y., Jeon, M., & Han, K.-H. (2018) · The Analyst · doi:10.1039/c7an01979c · Cited by 167
Metadata
- Authors
- Reboud, J., Bourquin, Y., Wilson, R., Pall, G. S., Jiwaji, M., Pitt, A. R., Graham, A., Waters, A. P., & Cooper, J. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-09-04
- Volume
- 109
- Issue
- 38
- Pages
- 15162-15167
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2000921235
- Cited by
- 220
- References
- 24
- FWCI
- 7.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.