Shaping acoustic fields as a toolset for microfluidic manipulations in diagnostic technologies
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Ultrasonics offers the possibility of developing sophisticated fluid manipulation tools in lab-on-a-chip technologies. Here we demonstrate the ability to shape ultrasonic fields by using phononic lattices, patterned on a disposable chip, to carry out the complex sequence of fluidic manipulations required to detect the rodent malaria parasite Plasmodium berghei in blood. To illustrate the different tools that are available to us, we used acoustic fields to produce the required rotational vortices that mechanically lyse both the red blood cells and the parasitic cells present in a drop of blood. This procedure was followed by the amplification of parasitic genomic sequences using different acoustic fields and frequencies to heat the sample and perform a real-time PCR amplification. The system does not require the use of lytic reagents nor enrichment steps, making it suitable for further integration into lab-on-a-chip point-of-care devices. This acoustic sample preparation and PCR enables us to detect ca. 30 parasites in a microliter-sized blood sample, which is the same order of magnitude in sensitivity as lab-based PCR tests. Unlike other lab-on-a-chip methods, where the sample moves through channels, here we use our ability to shape the acoustic fields in a frequency-dependent manner to provide different analytical functions. The methods also provide a clear route toward the integration of PCR to detect pathogens in a single handheld system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Weltgesundheitsorganisation (2005) · Cited by 3,799
Inhibition and facilitation of nucleic acid amplification
Wilson, I. G. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.10.3741-3751.1997 · Cited by 2,266 · cited 1×
“These may include the use of lytic agents, enzymes, or detergents, which can inhibit subsequent analysis and have to be removed (11), most usually using centrifugation before further processing.”
BackgroundMicrofluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979 · cited 1×
“Implementing such techniques has however been a particular difficulty in developing a fully integrated sample-to-answer solution for molecular diagnostics (20).”
BackgroundRapid Diagnostic Tests for Malaria Parasites
Moody, A. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.1.66-78.2002 · Cited by 1,418 · cited 2×
“0001% or 1 parasite∕μL of blood (30)] and better than routine smear diagnostic [500 parasite∕μL (30)] and rapid tests [>1;000∕μL (29)] and corresponded to a 1 day incubation after mouse infection.”
BackgroundResultPoint-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Microscale acoustofluidics: Microfluidics driven via acoustics and ultrasonics
Friend, J., & Yeo, L. Y. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.647 · Cited by 964 · cited 1×
“[0, 1].”
Ultrafast microfluidics using surface acoustic waves
Yeo, L. Y., & Friend, J. R. (2009) · Biomicrofluidics · doi:10.1063/1.3056040 · Cited by 391 · cited 2×
“and the surface tensions at the droplet pinning contact line, different wave amplitudes give rise to different phenomena (3), from streaming at low powers to movement, jetting, and nebulization at high power.”
BackgroundSurface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices
Franke, T., Abate, A. R., Weitz, D. A., & Wixforth, A. (2009) · Lab on a Chip · doi:10.1039/b906819h · Cited by 369
Surface acoustic wave actuated cell sorting (SAWACS)
Franke, T., Braunmüller, S., Schmid, L., Wixforth, A., & Weitz, D. A. (2010) · Lab on a Chip · doi:10.1039/b915522h · Cited by 363 · cited 1×
“Although only these two functions are combined here, the use of phononic lattices opens a wide range of applications and could be used to combine other SAWactuated techniques, such as the direction of drops for highthroughput analysis (21, 22) or nebulization (7).”
BackgroundCheng, J., Sheldon, E. L., Wu, L., Uribe, A., Gerrue, L. O., Carrino, J., Heller, M. J., & O'Connell, J. P. (1998) · Nature Biotechnology · doi:10.1038/nbt0698-541 · Cited by 347
Hydrodynamic Damage to Animal Cells
Chisti, Y. (2001) · Critical Reviews in Biotechnology · doi:10.1080/20013891081692 · Cited by 264 · cited 1×
“85 Pa under the conditions used for lysis (SI Appendix, Methods), sufficient for a mechanical disruptive effect on mammalian cells (26).”
MethodReagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation
Carlo, D. D., Jeong, K.-H., & Lee, L. P. (2003) · Lab on a Chip · doi:10.1039/b305162e · Cited by 246 · cited 2×
“SAW lysis efficiency was comparable to chemical and other mechanical lysis methods (17).”
ResultAccuracy of routine laboratory diagnosis of malaria in the United Kingdom.
Milne, L. M., Kyi, M. S., Chiodini, P. L., & Warhurst, D. C. (1994) · Journal of Clinical Pathology · doi:10.1136/jcp.47.8.740 · Cited by 228 · cited 1×
“0001% or 1 parasite∕μL of blood (30)] and better than routine smear diagnostic [500 parasite∕μL (30)] and rapid tests [>1;000∕μL (29)] and corresponded to a 1 day incubation after mouse infection.”
BackgroundAcoustically driven planar microfluidics
Wixforth, A. (2003) · Superlattices and Microstructures · doi:10.1016/j.spmi.2004.02.015 · Cited by 228
Siegrist, J., Gorkin, R. A., III, Bastien, M., Stewart, G., Peytavi, R., Kido, H., Bergeron, M. G., & Madou, M. J. (2009) · Lab on a Chip · doi:10.1039/b913219h · Cited by 126
Phononic crystal structures for acoustically driven microfluidic manipulations
Wilson, R., Reboud, J., Bourquin, Y., Neale, S. L., Zhang, Y., & Cooper, J. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00234h · Cited by 117
Self-citationDisposable real-time microPCR device: lab-on-a-chip at a low cost
Neužil, P., Pipper, J., & Hsieh, T. M. (2006) · Molecular BioSystems · doi:10.1039/b605957k · Cited by 114
Hodgson, R. P., Tan, M. K., Yeo, L. Y., & Friend, J. R. (2009) · Applied Physics Letters · doi:10.1063/1.3049128 · Cited by 102 · cited 1×
“1A) placed on the surface of the piezoelectric chip (4, 5), thus providing a low cost technology.”
BackgroundEschbach, E., Scharsack, J. P., John, U., & Medlin, L. K. (2001) · Journal of Applied Toxicology · doi:10.1002/jat.797 · Cited by 100 · cited 1×
“Haemoglobin released from the red blood cells was quantified by measuring direct light absorption at λ 1⁄4 414 nm and 540 nm (33).”
MethodPhononic Crystals for Shaping Fluids
Bourquin, Y., Wilson, R., Zhang, Y., Reboud, J., & Cooper, J. M. (2011) · Advanced Materials · doi:10.1002/adma.201004455 · Cited by 87
Self-citationRapid thermal lysis of cells using silicon–diamond microcantilever heaters
Privorotskaya, N. L., Liu, Y.-S., Lee, J., Zeng, H., Carlisle, J. A., Radadia, A. D., Millet, L. J., Bashir, R., & King, W. P. (2010) · Lab on a Chip · doi:10.1039/b923791g · Cited by 62 · cited 1×
“Although the dissipation of acoustic energy in the droplet will generate heat, the temperature of blood droplets during the SAW lysis only rises to 38 °C, confirming that the lysis process was not due to an increase in temperature (28).”
BackgroundReal-time PCR methods for monitoring antimalarial drug resistance
Wilson, P. E., Alker, A. P., & Meshnick, S. R. (2005) · Trends in Parasitology · doi:10.1016/j.pt.2005.04.007 · Cited by 57 · cited 1×
“Here we have demonstrated an efficient and sensitive device for malaria, where the analysis may help to identify drug resistance, at the point-of-care (31), which is not possible with microscopy.”
BackgroundNebulisation on a disposable array structured with phononic lattices
Reboud, J., Wilson, R., Zhang, Y., Ismail, M. H., Bourquin, Y., & Cooper, J. M. (2012) · Lab on a Chip · doi:10.1039/c2lc20705b · Cited by 43
Self-citation
Cited by
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Acoustic tweezers for the life sciences
Ozcelik, A., Rufo, J., Guo, F., Gu, Y., Li, P., Lata, J., & Huang, T. J. (2018) · Nature Methods · doi:10.1038/s41592-018-0222-9 · Cited by 826
Two-dimensional single-cell patterning with one cell per well driven by surface acoustic waves
Collins, D. J., Morahan, B., Garcia-Bustos, J., Doerig, C., Plebanski, M., & Neild, A. (2015) · Nature Communications · doi:10.1038/ncomms9686 · Cited by 588
Surface Acoustic Wave Microfluidics
Yeo, L. Y., & Friend, J. R. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141418 · Cited by 561
A Review on Macroscale and Microscale Cell Lysis Methods
Shehadul Islam, M., Aryasomayajula, A., & Selvaganapathy, P. (2017) · Micromachines · doi:10.3390/mi8030083 · Cited by 541
Metadata
- Authors
- Reboud, J., Bourquin, Y., Wilson, R., Pall, G. S., Jiwaji, M., Pitt, A. R., Graham, A., Waters, A. P., & Cooper, J. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-09-04
- Volume
- 109
- Issue
- 38
- Pages
- 15162-15167
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2000921235
- Cited by
- 220
- References
- 24
- FWCI
- 7.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.