Feeling the hidden mechanical forces in lipid bilayer is an original sense
Open accessThe DOI matches its Crossref record; 133 of the 133 references it cites were found in a registry or an index.
Abstract
Life’s origin entails enclosing a compartment to hoard material, energy, and information. The envelope necessarily comprises amphipaths, such as prebiotic fatty acids, to partition the two aqueous domains. The self-assembled lipid bilayer comes with a set of properties including its strong anisotropic internal forces that are chemically or physically malleable. Added bilayer stretch can alter force vectors on embedded proteins to effect conformational change. The force-from-lipid principle was demonstrated 25 y ago when stretches opened purified Escherichia coli MscL channels reconstituted into artificial bilayers. This reductionistic exercise has rigorously been recapitulated recently with two vertebrate mechanosensitive K + channels (TREK1 and TRAAK). Membrane stretches have also been known to activate various voltage-, ligand-, or Ca 2+ -gated channels. Careful analyses showed that Kv, the canonical voltage-gated channel, is in fact exquisitely sensitive even to very small tension. In an unexpected context, the canonical transient-receptor-potential channels in the Drosophila eye, long presumed to open by ligand binding, is apparently opened by membrane force due to PIP 2 hydrolysis-induced changes in bilayer strain. Being the intimate medium, lipids govern membrane proteins by physics as well as chemistry. This principle should not be a surprise because it parallels water’s paramount role in the structure and function of soluble proteins. Today, overt or covert mechanical forces govern cell biological processes and produce sensations. At the genesis, a bilayer’s response to osmotic force is likely among the first senses to deal with the capricious primordial sea.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The capsaicin receptor: a heat-activated ion channel in the pain pathway
Caterina, M. J., Schumacher, M. A., Tominaga, M., Rosen, T. A., Levine, J. D., & Julius, D. (1997) · Nature · doi:10.1038/39807 · Cited by 9,107
The Structure of the Potassium Channel: Molecular Basis of K + Conduction and Selectivity
Doyle, D. A., Cabral, J. M., Pfuetzner, R. A., Kuo, A., Gulbis, J. M., Cohen, S. L., Chait, B. T., & MacKinnon, R. (1998) · Science · doi:10.1126/science.280.5360.69 · Cited by 6,807
Smith, S. B., Cui, Y., & Bustamante, C. (1996) · Science · doi:10.1126/science.271.5250.795 · Cited by 2,770
Creation of a Bacterial Cell Controlled by a Chemically Synthesized Genome
Gibson, D. G., Glass, J. I., Lartigue, C., Noskov, V. N., Chuang, R.-Y., Algire, M. A., Benders, G. A., Montague, M. G., Ma, L., Moodie, M. M., et al. (2010) · Science · doi:10.1126/science.1190719 · Cited by 2,638
Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
Crystal Structure of a Mammalian Voltage-Dependent Shaker Family K + Channel
Long, S. B., Campbell, E. B., & MacKinnon, R. (2005) · Science · doi:10.1126/science.1116269 · Cited by 2,124
Structure of the TRPV1 ion channel determined by electron cryo-microscopy
Liao, M., Cao, E., Julius, D., & Cheng, Y. (2013) · Nature · doi:10.1038/nature12822 · Cited by 1,686
Measuring mechanical tension across vinculin reveals regulation of focal adhesion dynamics
Grashoff, C., Hoffman, B. D., Brenner, M. D., Zhou, R., Parsons, M., Yang, M. T., McLean, M. A., Sligar, S. G., Chen, C. S., Ha, T., et al. (2010) · Nature · doi:10.1038/nature09198 · Cited by 1,541
Stretching DNA with optical tweezers
Wang, M. D., Yin, H., Landick, R., Gelles, J., & Block, S. M. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78780-0 · Cited by 1,481
Atomic structure of a voltage-dependent K+ channel in a lipid membrane-like environment
Long, S. B., Tao, X., Campbell, E. B., & MacKinnon, R. (2007) · Nature · doi:10.1038/nature06265 · Cited by 1,411
Cited by
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652
“Although K2P channels have received the most attention for their mechanotransduction properties, the modulation of voltage gated potassium channels by mechanical force has also been recorded (Anishkin et al., 2014; Morris, 2011).”
InfluentialDiscoveries in structure and physiology of mechanically activated ion channels
Kefauver, J. M., Ward, A. B., & Patapoutian, A. (2020) · Nature · doi:10.1038/s41586-020-2933-1 · Cited by 604
Piezo1 Channels Are Inherently Mechanosensitive
Syeda, R., Florendo, M. N., Cox, C. D., Kefauver, J. M., Santos, J. S., Martinac, B., & Patapoutian, A. (2016) · Cell Reports · doi:10.1016/j.celrep.2016.10.033 · Cited by 532
OSCA/TMEM63 are an evolutionarily conserved family of mechanically activated ion channels
Murthy, S. E., Dubin, A. E., Whitwam, T., Jojoa-Cruz, S., Cahalan, S. M., Mousavi, S. A. R., Ward, A. B., & Patapoutian, A. (2018) · eLife · doi:10.7554/elife.41844 · Cited by 368
VRACs and other ion channels and transporters in the regulation of cell volume and beyond
Jentsch, T. J. (2016) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2016.29 · Cited by 353
Physical mechanism for gating and mechanosensitivity of the human TRAAK K+ channel
Brohawn, S. G., Campbell, E. B., & MacKinnon, R. (2014) · Nature · doi:10.1038/nature14013 · Cited by 341
Cytoskeletal to Nuclear Strain Transfer Regulates YAP Signaling in Mesenchymal Stem Cells
Driscoll, T. P., Cosgrove, B. D., Heo, S.-J., Shurden, Z. E., & Mauck, R. L. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.05.010 · Cited by 319
K2P channel gating mechanisms revealed by structures of TREK-2 and a complex with Prozac
Dong, Y. Y., Pike, A. C. W., Mackenzie, A., McClenaghan, C., Aryal, P., Dong, L., Quigley, A., Grieben, M., Goubin, S., Mukhopadhyay, S., et al. (2015) · Science · doi:10.1126/science.1261512 · Cited by 299
Mechanisms of mechanotransduction and physiological roles of PIEZO channels
Xiao, B. (2024) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-024-00773-5 · Cited by 287
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Wang, Y., Chi, S., Guo, H., Li, G., Wang, L., Zhao, Q., Rao, Y., Zu, L., He, W., & Xiao, B. (2018) · Nature Communications · doi:10.1038/s41467-018-03570-9 · Cited by 269
Functional states of myeloid cells in cancer
van Vlerken-Ysla, L., Tyurina, Y. Y., Kagan, V. E., & Gabrilovich, D. I. (2023) · Cancer Cell · doi:10.1016/j.ccell.2023.02.009 · Cited by 261
Ion Permeation and Mechanotransduction Mechanisms of Mechanosensitive Piezo Channels
Zhao, Q., Wu, K., Geng, J., Chi, S., Wang, Y., Zhi, P., Zhang, M., & Xiao, B. (2016) · Neuron · doi:10.1016/j.neuron.2016.01.046 · Cited by 233
“…to eukaryotic species and serve as mechanotransducers in various mechanotransduction processes such as touch and pain sensation, hearing, blood pressure regulation, and osmoregulation (Anishkin et al., 2014; Chalfie, 2009; Kung et al., 2010; Nilius and Honoré , 2012; Ranade et al., 2015).”
Fluids and Electrolytes under Confinement in Single-Digit Nanopores
Aluru, N. R., Aydin, F., Bazant, M. Z., Blankschtein, D., Brozena, A. H., de Souza, J. P., Elimelech, M., Faucher, S., Fourkas, J. T., Koman, V. B., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00155 · Cited by 224
Life behind the wall: sensing mechanical cues in plants
Hamant, O., & Haswell, E. S. (2017) · BMC Biology · doi:10.1186/s12915-017-0403-5 · Cited by 195
“On the other hand, the ownership of a plasma membrane is a fundamental characteristic of a cell, and correspondingly MS channels may provide a universal approach to force perception [114].”
BackgroundMechanical surface waves accompany action potential propagation
El Hady, A., & Machta, B. B. (2015) · Nature Communications · doi:10.1038/ncomms7697 · Cited by 171
“The MscL channel, a bacterial osmotic pressure sensor for which ∆A ∼ 20nm, can detect changes in tension smaller than 10−3N/m [45], while measured mechanosensitivity of Na channels is smaller, with a change in tension closer to 10−2N/m required [47].”
BackgroundHow Caenorhabditis elegans Senses Mechanical Stress, Temperature, and Other Physical Stimuli
Goodman, M. B., & Sengupta, P. (2019) · Genetics · doi:10.1534/genetics.118.300241 · Cited by 131
Metadata
- Authors
- Anishkin, A., Loukin, S. H., Teng, J., & Kung, C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2014-05-21
- Volume
- 111
- Issue
- 22
- Pages
- 7898-7905
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1976976361
- Cited by
- 300
- References
- 133
- FWCI
- 10.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.