Synthetic biology devices for in vitro and in vivo diagnostics
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
There is a growing need to enhance our capabilities in medical and environmental diagnostics. Synthetic biologists have begun to focus their biomolecular engineering approaches toward this goal, offering promising results that could lead to the development of new classes of inexpensive, rapidly deployable diagnostics. Many conventional diagnostics rely on antibody-based platforms that, although exquisitely sensitive, are slow and costly to generate and cannot readily confront rapidly emerging pathogens or be applied to orphan diseases. Synthetic biology, with its rational and short design-to-production cycles, has the potential to overcome many of these limitations. Synthetic biology devices, such as engineered gene circuits, bring new capabilities to molecular diagnostics, expanding the molecular detection palette, creating dynamic sensors, and untethering reactions from laboratory equipment. The field is also beginning to move toward in vivo diagnostics, which could provide near real-time surveillance of multiple pathological conditions. Here, we describe current efforts in synthetic biology, focusing on the translation of promising technologies into pragmatic diagnostic tools and platforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tight control of gene expression in mammalian cells by tetracycline-responsive promoters.
Gossen, M., & Bujard, H. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5547 · Cited by 4,943
Delivery of siRNA to the mouse brain by systemic injection of targeted exosomes
Alvarez-Erviti, L., Seow, Y., Yin, H., Betts, C., Lakhal, S., & Wood, M. J. A. (2011) · Nature Biotechnology · doi:10.1038/nbt.1807 · Cited by 4,930
A synthetic oscillatory network of transcriptional regulators
Elowitz, M. B., & Leibler, S. (2000) · Nature · doi:10.1038/35002125 · Cited by 4,630
Construction of a genetic toggle switch in Escherichia coli
Gardner, T. S., Cantor, C. R., & Collins, J. J. (2000) · Nature · doi:10.1038/35002131 · Cited by 4,268
Self-citationZFN, TALEN, and CRISPR/Cas-based methods for genome engineering
Gaj, T., Gersbach, C. A., & Barbas, C. F. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.04.004 · Cited by 3,820
Hornung, V., Bauernfeind, F., Halle, A., Samstad, E. O., Kono, H., Rock, K. L., Fitzgerald, K. A., & Latz, E. (2008) · Nature Immunology · doi:10.1038/ni.1631 · Cited by 3,065
A Logic-Gated Nanorobot for Targeted Transport of Molecular Payloads
Douglas, S. M., Bachelet, I., & Church, G. M. (2012) · Science · doi:10.1126/science.1214081 · Cited by 2,180
Tian, Y., Li, S., Song, J., Ji, T., Zhu, M., Anderson, G. J., Wei, J., & Nie, G. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.083 · Cited by 1,801
Molecular identification of a renal urate–anion exchanger that regulates blood urate levels
Enomoto, A., Kimura, H., Chairoungdua, A., Shigeta, Y., Jutabha, P., Ho Cha, S., Hosoyamada, M., Takeda, M., Sekine, T., Igarashi, T., et al. (2002) · Nature · doi:10.1038/nature742 · Cited by 1,535
Synthetic biology: applications come of age
Khalil, A. S., & Collins, J. J. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2775 · Cited by 1,373
Self-citation
Cited by
Rapid, Low-Cost Detection of Zika Virus Using Programmable Biomolecular Components
Pardee, K., Green, A. A., Takahashi, M. K., Braff, D., Lambert, G., Lee, J. W., Ferrante, T., Ma, D., Donghia, N., Fan, M., et al. (2016) · Cell · doi:10.1016/j.cell.2016.04.059 · Cited by 1,439
Self-citationCrosby, D., Bhatia, S., Brindle, K. M., Coussens, L. M., Dive, C., Emberton, M., Esener, S., Fitzgerald, R. C., Gambhir, S. S., Kuhn, P., et al. (2022) · Science · doi:10.1126/science.aay9040 · Cited by 1,379
“Other strategies include engineered diagnostics that are selectively activated in the presence of disease, such as molecular (85, 97) and biological (98) sensors that profile the in vivo tumormicroenvironment to generate synthetic biomarkers of disease.”
Engineering Customized Cell Sensing and Response Behaviors Using Synthetic Notch Receptors
Morsut, L., Roybal, K. T., Xiong, X., Gordley, R. M., Coyle, S. M., Thomson, M., & Lim, W. A. (2016) · Cell · doi:10.1016/j.cell.2016.01.012 · Cited by 1,000
Kojima, R., Bojar, D., Rizzi, G., Hamri, G. C.-E., El-Baba, M. D., Saxena, P., Ausländer, S., Tan, K. R., & Fussenegger, M. (2018) · Nature Communications · doi:10.1038/s41467-018-03733-8 · Cited by 748
“…be implanted into patients and secrete therapeutic proteins on demand 7, 8 , we anticipated that mammalian cells capable of being implanted in patients and secreting therapeutic exosomes loaded with biopharmaceutical-encoding mRNAs in-situ would also have potential therapeutic applications 8, 9 .”
An ingestible bacterial-electronic system to monitor gastrointestinal health
Mimee, M., Nadeau, P., Hayward, A., Carim, S., Flanagan, S., Jerger, L., Collins, J., McDonnell, S., Swartwout, R., Citorik, R. J., et al. (2018) · Science · doi:10.1126/science.aas9315 · Cited by 606
Self-citationWearable materials with embedded synthetic biology sensors for biomolecule detection
Nguyen, P. Q., Soenksen, L. R., Donghia, N. M., Angenent-Mari, N. M., de Puig, H., Huang, A., Lee, R., Slomovic, S., Galbersanini, T., Lansberry, G., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00950-3 · Cited by 560
Self-citationPoint-of-Care Diagnostics: Recent Developments in a Connected Age
Nayak, S., Blumenfeld, N. R., Laksanasopin, T., & Sia, S. K. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04630 · Cited by 508
Cell-free biosensors for rapid detection of water contaminants
Jung, J. K., Alam, K. K., Verosloff, M. S., Capdevila, D. A., Desmau, M., Clauer, P. R., Lee, J. W., Nguyen, P. Q., Pastén, P. A., Matiasek, S. J., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0571-7 · Cited by 402
Self-citationNeural Network Detection of Data Sequences in Communication Systems
Farsad, N., & Goldsmith, A. (2018) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2018.2868322 · Cited by 358
Cell-based biosensors: Recent trends, challenges and future perspectives
Gupta, N., Renugopalakrishnan, V., Liepmann, D., Paulmurugan, R., & Malhotra, B. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111435 · Cited by 318
A machine learning approach to predict metabolic pathway dynamics from time-series multiomics data
Costello, Z., & Martin, H. G. (2018) · npj Systems Biology and Applications · doi:10.1038/s41540-018-0054-3 · Cited by 242
Synthetic and systems biology for microbial production of commodity chemicals
Chubukov, V., Mukhopadhyay, A., Petzold, C. J., Keasling, J. D., & Martín, H. G. (2016) · npj Systems Biology and Applications · doi:10.1038/npjsba.2016.9 · Cited by 238
Synthetic biomarkers: a twenty-first century path to early cancer detection
Kwong, G. A., Ghosh, S., Gamboa, L., Patriotis, C., Srivastava, S., & Bhatia, S. N. (2021) · Nature Reviews Cancer · doi:10.1038/s41568-021-00389-3 · Cited by 209
Synthetic Biology—The Synthesis of Biology
Ausländer, S., Ausländer, D., & Fussenegger, M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201609229 · Cited by 206
Shao, J., Xue, S., Yu, G., Yu, Y., Yang, X., Bai, Y., Zhu, S., Yang, L., Yin, J., Wang, Y., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aal2298 · Cited by 202
Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies
Walper, S. A., Lasarte Aragonés, G., Sapsford, K. E., Brown, C. W., Rowland, C. E., Breger, J. C., & Medintz, I. L. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00420 · Cited by 161
AI-directed gene fusing prolongs the evolutionary half-life of synthetic gene circuits
(2025) · doi:10.1126/sciadv.adx0796 · Cited by 4
Metadata
- Authors
- Slomovic, S., Pardee, K., & Collins, J. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2015-11-23
- Volume
- 112
- Issue
- 47
- Pages
- 14429-14435
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2174637668
- Cited by
- 314
- References
- 84
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.