The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Layer-by-layer assembled fluorescent probes in the second near-infrared window for systemic delivery and detection of ovarian cancer
Open accessAbstract
Significance: Survival of cancer patients can be greatly improved by an ideal theranostic platform capable of early detection and effective treatment of tumors. Layer-by-layer (LbL) assembly is a well-established technology and matches the requirement of modularity and versatility for such a theranostic platform. Second near-infrared window (NIR-II) fluorescence imaging is a promising modality with high resolution, deep penetration, and diminished noise. This work, for the first time to our knowledge, establishes a modular and versatile LbL platform for NIR-II agents and presents a head-to-head in vivo comparison of available NIR-II probes. We successfully achieve the selective, noninvasive, and safe detection of high-grade serous ovarian tumors in an orthotopic murine model. These LbL NIR-II probes promise the development of an NIR-II based theranostic platform of disease diagnosis, progression, and treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of nanoparticle design for overcoming biological barriers to drug delivery
Blanco, E., Shen, H., & Ferrari, M. (2015) · Nature Biotechnology · doi:10.1038/nbt.3330 · Cited by 7,002 · cited 1×
“The completed LbL NPs, with a layered structure consisting of NIR-II emissive core/PLA/DXS/PLA/HA, possessed zeta potentials of approximately −30 mV and hydrodynamic diameters within the optimal range (10–200 nm) for systemic delivery (22, 23), except the SWNT (280 nm) because its unique elongated shape was not recogn…”
BackgroundRenal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476 · cited 1×
“Based on previous reports (24, 25), it is thought that QDs (∼6 nm), first encapsulated in amphiphilic PAA, can diffuse out of the LbL film and eventually be cleared via the renal system (26, 27).”
MethodFactors affecting the clearance and biodistribution of polymeric nanoparticles
Alexis, F., Pridgen, E., Molnar, L. K., & Farokhzad, O. C. (2008) · Molecular Pharmaceutics · doi:10.1021/mp800051m · Cited by 3,699
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778 · cited 1×
“Based on previous reports (24, 25), it is thought that QDs (∼6 nm), first encapsulated in amphiphilic PAA, can diffuse out of the LbL film and eventually be cleared via the renal system (26, 27).”
MethodA route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Dreaden, E. C., Morton, S. W., Shopsowitz, K. E., Choi, J.-H., Deng, Z. J., Cho, N.-J., & Hammond, P. T. (2014) · ACS Nano · doi:10.1021/nn502861t · Cited by 179
Self-citation
Cited by
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Li, J., & Pu, K. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00001h · Cited by 1,168
Hu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126
Near‐Infrared‐II Molecular Dyes for Cancer Imaging and Surgery
Zhu, S., Tian, R., Antaris, A. L., Chen, X., & Dai, H. (2019) · Advanced Materials · doi:10.1002/adma.201900321 · Cited by 972
Lifetime-engineered NIR-II nanoparticles unlock multiplexed in vivo imaging
Fan, Y., Wang, P., Lu, Y., Wang, R., Zhou, L., Zheng, X., Li, X., Piper, J. A., & Zhang, F. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0221-0 · Cited by 795
Metadata
- Authors
- Dang, X., Gu, L., Qi, J., Correa, S., Zhang, G., Belcher, A. M., & Hammond, P. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2016-04-25
- Volume
- 113
- Issue
- 19
- Pages
- 5179-5184
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2342399740
- Cited by
- 189
- References
- 8
- FWCI
- 13.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.