Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
We report a microarray of cantilevers to detect multiple unlabeled biomolecules simultaneously at nanomolar concentrations within minutes. Ligand-receptor binding interactions such as DNA hybridization or protein recognition occurring on microfabricated silicon cantilevers generate nanomechanical bending, which is detected optically in situ . Differential measurements including reference cantilevers on an array of eight sensors can sequence-specifically detect unlabeled DNA targets in 80-fold excess of nonmatching DNA as a background and discriminate 3′ and 5′ overhangs. Our experiments suggest that the nanomechanical motion originates from predominantly steric hindrance effects and depends on the concentration of DNA molecules in solution. We show that cantilever arrays can be used to investigate the thermodynamics of biomolecular interactions mechanically, and we have found that the specificity of the reaction on a cantilever is consistent with solution data. Hence cantilever arrays permit multiple binding assays in parallel and can detect femtomoles of DNA on the cantilever at a DNA concentration in solution of 75 nM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
The tension of metallic films deposited by electrolysis
Stoney, G. G. (1909) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1909.0021 · Cited by 4,872
Printing Proteins as Microarrays for High-Throughput Function Determination
MacBeath, G., & Schreiber, S. L. (2000) · Science · doi:10.1126/science.289.5485.1760 · Cited by 2,767
Wang, D. G., Fan, J.-B., Siao, C.-J., Berno, A., Young, P., Sapolsky, R., Ghandour, G., Perkins, N., Winchester, E., Spencer, J., et al. (1998) · Science · doi:10.1126/science.280.5366.1077 · Cited by 2,161
Predicting DNA duplex stability from the base sequence
Breslauer, K. J., Frank, R., Blöcker, H., & Marky, L. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.11.3746 · Cited by 1,837
Expression profiling using cDNA microarrays
Duggan, D. J., Bittner, M., Chen, Y., Meltzer, P., & Trent, J. M. (1999) · Nature Genetics · doi:10.1038/4434 · Cited by 1,657
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Self-citationCharacterization of DNA Probes Immobilized on Gold Surfaces
Herne, T. M., & Tarlov, M. J. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9719586 · Cited by 1,541
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,013
Molecular interactions on microarrays
Southern, E., Mir, K., & Shchepinov, M. (1999) · Nature Genetics · doi:10.1038/4429 · Cited by 774
Cited by
Synthetic Molecular Motors and Mechanical Machines
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200504313 · Cited by 2,609
Erbas-Cakmak, S., Leigh, D. A., McTernan, C. T., & Nussbaumer, A. L. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00146 · Cited by 1,982
Systems Biology and New Technologies Enable Predictive and Preventative Medicine
Hood, L., Heath, J. R., Phelps, M. E., & Lin, B. (2004) · Science · doi:10.1126/science.1104635 · Cited by 1,108
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Atomic force microscopy as a multifunctional molecular toolbox in nanobiotechnology
Müller, D. J., & Dufrêne, Y. F. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.100 · Cited by 752
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Synthetische molekulare Motoren und mechanische Maschinen
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200504313 · Cited by 624
Jianrong, C., Yuqing, M., Nongyue, H., Xiaohua, W., & Sijiao, L. (2004) · Biotechnology Advances · doi:10.1016/j.biotechadv.2004.03.004 · Cited by 573
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
Nanotechnology in clinical laboratory diagnostics
Jain, K. K. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.03.014 · Cited by 453
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Label-free protein assay based on a nanomechanical cantilever array
Arntz, Y., Seelig, J. D., Lang, H. P., Zhang, J., Hunziker, P., Ramseyer, J. P., Meyer, E., Hegner, M., & Gerber, C. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/319 · Cited by 409
Self-citationBiosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Nanodiagnostics: application of nanotechnology in molecular diagnostics
Jain, K. (2003) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.3.2.153 · Cited by 372
Longo, G., Alonso-Sarduy, L., Rio, L. M., Bizzini, A., Trampuz, A., Notz, J., Dietler, G., & Kasas, S. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.120 · Cited by 368
Microcantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Nanotechnology for Early Cancer Detection
Choi, Y.-E., Kwak, J.-W., & Park, J. W. (2010) · Sensors · doi:10.3390/s100100428 · Cited by 329
Bian, K., Gerber, C., Heinrich, A. J., Müller, D. J., Scheuring, S., & Jiang, Y. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00033-2 · Cited by 314
Self-citationRapid and label-free nanomechanical detection of biomarker transcripts in human RNA
Zhang, J., Lang, H. P., Huber, F., Bietsch, A., Grange, W., Certa, U., Mckendry, R., Güntherodt, H.-J., Hegner, M., & Gerber, C. (2006) · Nature Nanotechnology · doi:10.1038/nnano.2006.134 · Cited by 303
Self-citationGlucose Biosensor Based on the Microcantilever
Pei, J., Tian, F., & Thundat, T. (2004) · Analytical Chemistry · doi:10.1021/ac035048k · Cited by 284
A label-free immunosensor array using single-chain antibody fragments
Backmann, N., Zahnd, C., Huber, F., Bietsch, A., Plückthun, A., Lang, H.-P., Güntherodt, H.-J., Hegner, M., & Gerber, C. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504917102 · Cited by 284
Self-citationJain, K. K. (2017) · Springer eBooks · doi:10.1007/978-1-4939-6966-1 · Cited by 264
Fritz, J. (2008) · The Analyst · doi:10.1039/b718174d · Cited by 254
Oligonucleotide microarrays in microbial diagnostics
BODROSSY, L., & SESSITSCH, A. (2004) · Current Opinion in Microbiology · doi:10.1016/j.mib.2004.04.005 · Cited by 251
Nanobiotechnology: the promise and reality of new approaches to molecular recognition
Fortina, P., Kricka, L. J., Surrey, S., & Grodzinski, P. (2005) · Trends in Biotechnology · doi:10.1016/j.tibtech.2005.02.007 · Cited by 241
Emerging applications of nanomedicine for the diagnosis and treatment of cardiovascular diseases
Godin, B., Sakamoto, J. H., Serda, R. E., Grattoni, A., Bouamrani, A., & Ferrari, M. (2010) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2010.01.003 · Cited by 236
“Nanocantilevers can be used as multiple labelfree assays for detection of DNA species or circulating protein biomarkers [50].”
BackgroundMiniaturised nucleic acid analysis
Auroux, P.-A., Koc, Y., deMello, A., Manz, A., & Day, P. J. R. (2004) · Lab on a Chip · doi:10.1039/b408850f · Cited by 234
Braun, T., Ghatkesar, M. K., Backmann, N., Grange, W., Boulanger, P., Letellier, L., Lang, H.-P., Bietsch, A., Gerber, C., & Hegner, M. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2008.398 · Cited by 224
Self-citationLabel-free detection of DNA hybridization based on hydration-induced tension in nucleic acid films
Mertens, J., Rogero, C., Calleja, M., Ramos, D., Martín-Gago, J. A., Briones, C., & Tamayo, J. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.91 · Cited by 202
Microcantilever-based platforms as biosensing tools
Alvarez, M., & Lechuga, L. M. (2010) · The Analyst · doi:10.1039/b908503n · Cited by 185
Bimaterial Microcantilevers as a Hybrid Sensing Platform
Singamaneni, S., LeMieux, M. C., Lang, H. P., Gerber, C., Lam, Y., Zauscher, S., Datskos, P. G., Lavrik, N. V., Jiang, H., Naik, R. R., et al. (2008) · Advanced Materials · doi:10.1002/adma.200701667 · Cited by 185
Self-citationOptical microarray biosensing techniques
Bally, M., Halter, M., Vörös, J., & Grandin, H. M. (2006) · Surface and Interface Analysis · doi:10.1002/sia.2375 · Cited by 166
Cantilever Sensors: Nanomechanical Tools for Diagnostics
Datar, R., Kim, S., Jeon, S., Hesketh, P., Manalis, S., Boisen, A., & Thundat, T. (2009) · MRS Bulletin · doi:10.1557/mrs2009.121 · Cited by 163
Gfeller, K. Y., Nugaeva, N., & Hegner, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.018 · Cited by 161
“Such cantilever sensors are successfully applied in the field of genomics (Fritz et al., 2000; Hansen et al., 2001; McKendry et al., 2002), gas-sensing (Baller et al., 2000), and proteomics (Arntz et al., 2003; Liu et al., 2003; Moulin et al., 2000).”
BackgroundSelf-citationHighly sensitive polymer-based cantilever-sensors for DNA detection
Calleja, M., Nordström, M., Álvarez, M., Tamayo, J., Lechuga, L. M., & Boisen, A. (2005) · Ultramicroscopy · doi:10.1016/j.ultramic.2005.06.039 · Cited by 159
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51
“McKendry et al. (2002) reported the use of an array of microcantilevers with the capability of multiple binding assays in parallel with sensitivity towards DNA fragments in the femtomole range.”
Metadata
- Authors
- McKendry, R., Zhang, J., Arntz, Y., Strunz, T., Hegner, M., Lang, H. P., Baller, M. K., Certa, U., Meyer, E., Güntherodt, H.-J., & Gerber, C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-07-15
- Volume
- 99
- Issue
- 15
- Pages
- 9783-9788
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2117228527
- Cited by
- 598
- References
- 17
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.