The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Paper-based microfluidics for DNA diagnostics of malaria in low resource underserved rural communities
Open accessAbstract
Rapid, low-cost, species-specific diagnosis, based upon DNA testing, is becoming important in the treatment of patients with infectious diseases. Here, we demonstrate an innovation that uses origami to enable multiplexed, sensitive assays that rival polymerase chain reactions (PCR) laboratory assays and provide high-quality, fast precision diagnostics for malaria. The paper-based microfluidic technology proposed here combines vertical flow sample-processing steps, including paper folding for whole-blood sample preparation, with an isothermal amplification and a lateral flow detection, incorporating a simple visualization system. Studies were performed in village schools in Uganda with individual diagnoses being completed in <50 min (faster than the standard laboratory-based PCR). The tests, which enabled the diagnosis of malaria species in patients from a finger prick of whole blood, were both highly sensitive and specific, detecting malaria in 98% of infected individuals in a double-blind first-in-human study. Our method was more sensitive than other field-based, benchmark techniques, including optical microscopy and industry standard rapid immunodiagnostic tests, both performed by experienced local healthcare teams (which detected malaria in 86% and 83% of cases, respectively). All assays were independently validated using a real-time double-blinded reference PCR assay. We not only demonstrate that advanced, low-cost DNA-based sensors can be implemented in underserved communities at the point of need but also highlight the challenges associated with developing and implementing new diagnostic technologies in the field, without access to laboratories or infrastructure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lozano, R., Naghavi, M., Foreman, K., Lim, S., Shibuya, K., Aboyans, V., Abraham, J., Adair, T., Aggarwal, R., Ahn, S. Y., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61728-0 · Cited by 14,070
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
The ImageJ ecosystem: An open platform for biomedical image analysis
Schindelin, J., Rueden, C. T., Hiner, M. C., & Eliceiri, K. W. (2015) · Molecular Reproduction and Development · doi:10.1002/mrd.22489 · Cited by 2,636
Isothermal Amplification of Nucleic Acids
Zhao, Y., Chen, F., Li, Q., Wang, L., & Fan, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00428 · Cited by 1,775
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
A Review of Malaria Diagnostic Tools: Microscopy and Rapid Diagnostic Test (RDT)
Wongsrichanalai, C., Barcus, M. J., Muth, S., Sutamihardja, A., & Wernsdorfer, W. H. (2007) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2007.77.119 · Cited by 939
Requirements for Minimum Sample Size for Sensitivity and Specificity Analysis
Bujang, M. A. (2016) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2016/18129.8744 · Cited by 624
The silent threat: asymptomatic parasitemia and malaria transmission
Lindblade, K. A., Steinhardt, L., Samuels, A., Kachur, S. P., & Slutsker, L. (2013) · Expert Review of Anti-infective Therapy · doi:10.1586/eri.13.45 · Cited by 600 · cited 1×
“Light microscopy has long been the “go-to” standard technique used to diagnose malaria in such areas, and requires only a microscope and a trained technician to achieve detection sensitivities of 100 parasites per microliter of blood (4).”
MethodTurning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Paper-based nanobiosensors for diagnostics
Parolo, C., & Merkoçi, A. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35255a · Cited by 550
Rougemont, M., Van Saanen, M., Sahli, R., Hinrikson, H. P., Bille, J., & Jaton, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.12.5636-5643.2004 · Cited by 469
Yamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Operational strategies to achieve and maintain malaria elimination
Moonen, B., Cohen, J. M., Snow, R. W., Slutsker, L., Drakeley, C., Smith, D. L., Abeyasinghe, R. R., Rodriguez, M. H., Maharaj, R., Tanner, M., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(10)61269-x · Cited by 381
Hemingway, J., Shretta, R., Wells, T. N. C., Bell, D., Djimdé, A. A., Achee, N., & Qi, G. (2016) · PLOS Biology · doi:10.1371/journal.pbio.1002380 · Cited by 293
Hopkins, H., González, I. J., Polley, S. D., Angutoko, P., Ategeka, J., Asiimwe, C., Agaba, B., Kyabayinze, D. J., Sutherland, C. J., Perkins, M. D., et al. (2013) · The Journal of Infectious Diseases · doi:10.1093/infdis/jit184 · Cited by 289
“Paper Machine” for Molecular Diagnostics
Connelly, J. T., Rolland, J. P., & Whitesides, G. M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00411 · Cited by 289
Han, E.-T., Watanabe, R., Sattabongkot, J., Khuntirat, B., Sirichaisinthop, J., Iriko, H., Jin, L., Takeo, S., & Tsuboi, T. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02117-06 · Cited by 277
Wu, L., van den Hoogen, L. L., Slater, H., Walker, P. G. T., Ghani, A. C., Drakeley, C. J., & Okell, L. C. (2015) · Nature · doi:10.1038/nature16039 · Cited by 247
Govindarajan, A. V., Ramachandran, S., Vigil, G. D., Yager, P., & Böhringer, K. F. (2012) · Lab Chip · doi:10.1039/c1lc20622b · Cited by 177
A digital microfluidic system for serological immunoassays in remote settings
Ng, A. H. C., Fobel, R., Fobel, C., Lamanna, J., Rackus, D. G., Summers, A., Dixon, C., Dryden, M. D. M., Lam, C., Ho, M., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aar6076 · Cited by 172
Das, S., Jang, I. K., Barney, B., Peck, R. B., Rek, J. C., Arinaitwe, E., Adrama, H., Murphy, M., Imwong, M., Ling, C. L., et al. (2017) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.17-0245 · Cited by 168
Polley, S. D., Mori, Y., Watson, J., Perkins, M. D., González, I. J., Notomi, T., Chiodini, P. L., & Sutherland, C. J. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.00355-10 · Cited by 167
An innovative tool for moving malaria PCR detection of parasite reservoir into the field
Canier, L., Khim, N., Kim, S., Sluydts, V., Heng, S., Dourng, D., Eam, R., Chy, S., Khean, C., Loch, K., et al. (2013) · Malaria Journal · doi:10.1186/1475-2875-12-405 · Cited by 160
Paper‐Origami‐Based Multiplexed Malaria Diagnostics from Whole Blood
Xu, G., Nolder, D., Reboud, J., Oguike, M. C., van Schalkwyk, D. A., Sutherland, C. J., & Cooper, J. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201606060 · Cited by 160
Self-citationBritton, S., Cheng, Q., & McCarthy, J. S. (2016) · Malaria Journal · doi:10.1186/s12936-016-1158-0 · Cited by 132
Paper-based RNA detection and multiplexed analysis for Ebola virus diagnostics
Magro, L., Jacquelin, B., Escadafal, C., Garneret, P., Kwasiborski, A., Manuguerra, J., Monti, F., Sakuntabhai, A., Vanhomwegen, J., Lafaye, P. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00758-9 · Cited by 131
Cook, J. A., Aydin-Schmidt, B., González, I. J., Bell, D., Edlund, E., Nassor, M. H., Msellem, M. I., Ali, A., Abass, A. K., Mårtensson, A., et al. (2015) · Malaria Journal · doi:10.1186/s12936-015-0573-y · Cited by 130
Iwai, K., Shih, K.-C., Lin, X.-G., Brubaker, T. A., Sochol, R., & Lin, L.-W. (2014) · Lab on a Chip · doi:10.1039/c4lc00500g · Cited by 128
Paper microfluidics for nucleic acid amplification testing (NAAT) of infectious diseases
Magro, L., Escadafal, C., Garneret, P., Jacquelin, B., Kwasiborski, A., Manuguerra, J., Monti, F., Sakuntabhai, A., Vanhomwegen, J., Lafaye, P. J., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00013h · Cited by 128
CD-Based Microfluidics for Primary Care in Extreme Point-of-Care Settings
Smith, S., Mager, D., Perebikovsky, A., Shamloo, E., Kinahan, D. J., Mishra, R., Delgado, S. T., Kido, H., Saha, S., Ducrée, J., et al. (2016) · Micromachines · doi:10.3390/mi7020022 · Cited by 118
Yang, Z., Xu, G., Reboud, J., Ali, S. A., Kaur, G., McGiven, J. A., Boby, N., Gupta, P. K., Chaudhuri, P., & Cooper, J. M. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00825 · Cited by 117
Self-citationKurosaki, Y., Magassouba, N., Oloniniyi, O. K., Chérif, M. S., Sakabe, S., Takada, A., Hirayama, K., & Yasuda, J. (2016) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0004472 · Cited by 113
Pullulan Encapsulation of Labile Biomolecules to Give Stable Bioassay Tablets
Jahanshahi‐Anbuhi, S., Pennings, K., Leung, V., Liu, M., Carrasquilla, C., Kannan, B., Li, Y., Pelton, R. H., Brennan, J. D., & Filipe, C. D. M. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201403222 · Cited by 102
Hsiang, M. S., Lin, M., Dokomajilar, C., Kemere, J., Pilcher, C. D., Dorsey, G., & Greenhouse, B. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.00522-10 · Cited by 97
the Collaborative Study Group, Padley, D. J., Heath, A., Sutherland, C. J., Chiodini, P. L., & Baylis, S. A. (2008) · Malaria Journal · doi:10.1186/1475-2875-7-139 · Cited by 79
Alemayehu, S., Feghali, K. C., Cowden, J., Komisar, J. L., Ockenhouse, C. F., & Kamau, E. T. (2013) · Malaria Journal · doi:10.1186/1475-2875-12-277 · Cited by 77
False-Positive Results for Rapid Diagnostic Tests for Malaria in Patients with Rheumatoid Factor
Lee, J.-H., Jang, J. W., Cho, C. H., Kim, J. Y., Han, E., Yun, S. G., & Lim, C. S. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.01797-14 · Cited by 71
Field evaluation of diagnostic performance of malaria rapid diagnostic tests in western Kenya
Wanja, E. W., Kuya, N. A., Morang’a, C. M., Hickman, M. R., Johnson, J. D., Moseti, C., Anova, L., Ogutu, B. R., & Ohrt, C. (2016) · Malaria Journal · doi:10.1186/s12936-016-1508-y · Cited by 69
Presumptive Treatment of Malaria from Formal and Informal Drug Vendors in Nigeria
Isiguzo, C., Anyanti, J., Ujuju, C. N., Nwokolo, E., Cruz, A. D. L., Schatzkin, E., Modrek, S., Montagu, D., & Liu, J. X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110361 · Cited by 60
Feleke, D. G., Tarko, S., & Hadush, H. (2017) · BMC Infectious Diseases · doi:10.1186/s12879-017-2503-9 · Cited by 32
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
RT‐LAMP for rapid diagnosis of coronavirus SARS‐CoV‐2
Huang, W. E., Lim, B., Hsu, C., Xiong, D., Wu, W., Yu, Y., Jia, H., Wang, Y., Zeng, Y., Ji, M., et al. (2020) · Microbial Biotechnology · doi:10.1111/1751-7915.13586 · Cited by 497
Paper-based microfluidics: Simplified fabrication and assay methods
Nishat, S., Jafry, A. T., Martinez, A. W., & Awan, F. R. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129681 · Cited by 392
Detection of COVID-19: A review of the current literature and future perspectives
Ji, T., Liu, Z., Wang, G., Guo, X., Akbar khan, S., Lai, C., Chen, H., Huang, S., Xia, S., Chen, B., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112455 · Cited by 383
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Metadata
- Authors
- Reboud, J., Xu, G., Garrett, A., Adriko, M., Yang, Z., Tukahebwa, E. M., Rowell, C., & Cooper, J. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2019-02-19
- Volume
- 116
- Issue
- 11
- Pages
- 4834-4842
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2916501589
- Cited by
- 351
- References
- 41
- FWCI
- 16.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.