The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda
Open accessAbstract
BACKGROUND: Current malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too complex for field deployment. A new commercial molecular assay based on loop-mediated isothermal amplification (LAMP) was assessed for field use. METHODS: Malaria LAMP (Eiken Chemical, Japan) was evaluated for samples from 272 outpatients at a rural Ugandan clinic and compared with expert microscopy, nested PCR, and quantitative PCR (qPCR). Two technicians performed the assay after 3 days of training, using 2 alternative blood sample-preparation methods and visual interpretation of results by fluorescence assay. RESULTS: Compared with 3-well nested PCR, the sensitivity of both LAMP and single-well nested PCR was 90%; the microscopy sensitivity was 51%. For samples with a Plasmodium falciparum qPCR titer of ≥ 2 parasites/µL, LAMP sensitivity was 97.8% (95% confidence interval, 93.7%-99.5%). Most false-negative LAMP results involved samples with parasitemia levels detectable by 3-well nested PCR but very low or undetectable by qPCR. CONCLUSIONS: Malaria LAMP in a remote Ugandan clinic achieved sensitivity similar to that of single-well nested PCR in a United Kingdom reference laboratory. LAMP dramatically lowers the detection threshold achievable in malaria-endemic settings, providing a new tool for diagnosis, surveillance, and screening in elimination strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Okell, L. C., Ghani, A. C., Lyons, E., & Drakeley, C. J. (2009) · The Journal of Infectious Diseases · doi:10.1086/644781 · Cited by 532
Shrinking the malaria map: progress and prospects
Feachem, R. G., Phillips, A. A., Hwang, J., Cotter, C., Wielgosz, B., Greenwood, B. M., Sabot, O., Rodriguez, M. H., Abeyasinghe, R. R., Ghebreyesus, T. A., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(10)61270-6 · Cited by 429
Alves, F. P., Durlacher, R. R., Menezes, M. J., Krieger, H., Silva, L. H. P., & Camargo, E. P. (2002) · The American journal of tropical medicine and hygiene · doi:10.4269/ajtmh.2002.66.641 · Cited by 306
Real-Time Fluorescence Loop Mediated Isothermal Amplification for the Diagnosis of Malaria
Lucchi, N. W., Demas, A., Narayanan, J., Sumari, D., Kabanywanyi, A., Kachur, S. P., Barnwell, J. W., & Udhayakumar, V. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013733 · Cited by 198
Polley, S. D., Mori, Y., Watson, J., Perkins, M. D., González, I. J., Notomi, T., Chiodini, P. L., & Sutherland, C. J. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.00355-10 · Cited by 167
Self-citationLoop-Mediated Isothermal PCR (LAMP) for the Diagnosis of Falciparum Malaria
Paris, D. H., Imwong, M., Faiz, A. M., Hasan, M., Yunus, E. B., Silamut, K., Lee, S. J., Day, N. P. J., & Dondorp, A. M. (2007) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2007.77.972 · Cited by 132
Comparative Diagnosis of Malaria Infections by Microscopy, Nested PCR, and LAMP in Northern Thailand
Pöschl, B., Waneesorn, J., Thekisoe, O., Chutipongvivate, S., & Panagiotis, K. (2010) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2010.09-0630 · Cited by 94 · cited 1×
“Several evaluations of malaria LAMP assays have reported detection of cultured parasites or field samples transported to research laboratories [35–38]; one study evaluated another”
BackgroundCampos, I. M., Uribe, M. L., Cuesta, C., Franco-Gallego, A., Carmona-Fonseca, J., & Maestre, A. (2011) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2011.10-0507 · Cited by 59
Cited by
Asymptomatic malaria infections: detectability, transmissibility and public health relevance
Bousema, T., Okell, L., Felger, I., & Drakeley, C. (2014) · Nature Reviews Microbiology · doi:10.1038/nrmicro3364 · Cited by 696
Hofmann, N., Mwingira, F., Shekalaghe, S., Robinson, L. J., Mueller, I., & Felger, I. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001788 · Cited by 413
Reboud, J., Xu, G., Garrett, A., Adriko, M., Yang, Z., Tukahebwa, E. M., Rowell, C., & Cooper, J. M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1812296116 · Cited by 351
Emerging Technologies for the Clinical Microbiology Laboratory
Buchan, B. W., & Ledeboer, N. A. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00003-14 · Cited by 297
Malaria rapid diagnostic tests: challenges and prospects
Mouatcho, J. C., & Goldring, J. P. D. (2013) · Journal of Medical Microbiology · doi:10.1099/jmm.0.052506-0 · Cited by 291
Metadata
- Authors
- Hopkins, H., González, I. J., Polley, S. D., Angutoko, P., Ategeka, J., Asiimwe, C., Agaba, B., Kyabayinze, D. J., Sutherland, C. J., Perkins, M. D., & Bell, D.
- Venue
- The Journal of Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-04-30
- Volume
- 208
- Issue
- 4
- Pages
- 645-652
- ISSN
- 0022-1899 (ISSN-L)
- 1537-6613
- OpenAlex
- W2152873423
- Cited by
- 289
- References
- 8
- FWCI
- 38.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda. https://app.cochat.ai/papers/10.1093/infdis/jit184
- The paper
- Hopkins, H., González, I. J., Polley, S. D., Angutoko, P., Ategeka, J., Asiimwe, C., Agaba, B., Kyabayinze, D. J., Sutherland, C. J., Perkins, M. D., & Bell, D. (2013). Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda. The Journal of Infectious Diseases. https://doi.org/10.1093/infdis/jit184
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.