Separation of human breast cancer cells from blood by differential dielectric affinity.
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Electrorotation measurements were used to demonstrate that the dielectric properties of the metastatic human breast cancer cell line MDA231 were significantly different from those of erythrocytes and T lymphocytes. These dielectric differences were exploited to separate the cancer cells from normal blood cells by appropriately balancing the hydrodynamic and dielectrophoretic forces acting on the cells within a dielectric affinity column containing a microelectrode array. The operational criteria for successful particle separation in such a column are analyzed and our findings indicate that the dielectric affinity technique may prove useful in a wide variety of cell separation and characterization applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Self-citationLong-term human breast carcinoma cell lines of metastatic origin: Preliminary characterization
Cailleau, R., Olivé, M., & Cruciger, Q. V. J. (1978) · In Vitro · doi:10.1007/bf02616120 · Cited by 679
Stochastic model for electric field-induced membrane pores electroporation
Sugar, I. P., & Neumann, E. (1984) · Biophysical Chemistry · doi:10.1016/0301-4622(84)87003-9 · Cited by 284
Control by pulse parameters of electric field-mediated gene transfer in mammalian cells
Wolf, H., Rols, M. P., Boldt, E., Neumann, E., & Teissié, J. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80805-7 · Cited by 230
Wang, X.-B., Huang, Y., Gascoyne, P. R. C., Becker, F. F., Hölzel, R., & Pethig, R. (1994) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(94)90170-8 · Cited by 193
Self-citationZhang, R., Fidler, I. J., & Price, J. E. (1991) · PubMed · Cited by 171
Gascoyne, P. R. C., Pethig, R., Burt, J. P. H., & Becker, F. F. (1993) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(93)90032-u · Cited by 114
Self-citationHypotonically induced changes in the plasma membrane of cultured mammalian cells
Sukhorukov, V. L., Arnold, W. M., & Zimmermann, U. (1993) · The Journal of Membrane Biology · doi:10.1007/bf00233049 · Cited by 108
Dielectric properties of yeast cells as determined by electrorotation
Hölzel, R., & Lamprecht, I. (1992) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(92)90150-k · Cited by 97
Crawford, F. G., Vermund, S. H., & Katz, M. (1988) · CRC Critical Reviews in Microbiology · doi:10.3109/10408418809104469 · Cited by 89
Cited by
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
Self-citationAc electrokinetics: a review of forces in microelectrode structures
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/18/021 · Cited by 1,233
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Self-citationParticle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Microfluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Separation of Submicron Bioparticles by Dielectrophoresis
Morgan, H., Hughes, M. P., & Green, N. G. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76908-0 · Cited by 523
Circulating tumor cell technologies
Ferreira, M. M., Ramani, V. C., & Jeffrey, S. S. (2016) · Molecular Oncology · doi:10.1016/j.molonc.2016.01.007 · Cited by 511
Physicochemical Properties of Cells and Their Effects on Intrinsically Disordered Proteins (IDPs)
Theillet, F.-X., Binolfi, A., Frembgen-Kesner, T., Hingorani, K., Sarkar, M., Kyne, C., Li, C., Crowley, P. B., Gierasch, L., Pielak, G. J., et al. (2014) · Chemical Reviews · doi:10.1021/cr400695p · Cited by 503
Portable Filter-Based Microdevice for Detection and Characterization of Circulating Tumor Cells
Lin, H. K., Zheng, S., Williams, A. J., Balic, M., Groshen, S., Scher, H. I., Fleisher, M., Stadler, W., Datar, R. H., Tai, Y.-C., et al. (2010) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-10-1105 · Cited by 451
Single cell dielectric spectroscopy
Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/1/s10 · Cited by 445
Moon, H.-S., Kwon, K., Kim, S.-I., Han, H., Sohn, J., Lee, S., & Jung, H.-I. (2011) · Lab on a Chip · doi:10.1039/c0lc00345j · Cited by 437
Isolation of rare cells from cell mixtures by dielectrophoresis
Gascoyne, P. R. C., Noshari, J., Anderson, T. J., & Becker, F. F. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800373 · Cited by 436
Self-citationMarker-specific sorting of rare cells using dielectrophoresis
Hu, X., Bessette, P. H., Qian, J., Meinhart, C. D., Daugherty, P. S., & Soh, H. T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507719102 · Cited by 428
Dielectrophoresis in microfluidics technology
Çetin, B., & Li, D. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100167 · Cited by 411
Dielectrophoretic separation of cancer cells from blood
Gascoyne, P. R. C., Wang, X.-B., Huang, Y., & Becker, F. F. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.585856 · Cited by 406
Self-citationAhn, J. C., Teng, P., Chen, P., Posadas, E., Tseng, H., Lu, S. C., & Yang, J. D. (2021) · Hepatology · doi:10.1002/hep.31165 · Cited by 338
Dielectrophoresis-Based Sample Handling in General-Purpose Programmable Diagnostic Instruments
Gascoyne, P. R. C., & Vykoukal, J. V. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820535 · Cited by 321
Self-citationMicro- and nanofluidics for DNA analysis
Tegenfeldt, J. O., Prinz, C., Huang, R. L., Austin, R. H., Chou, S. Y., Cox, E. C., Sturm, J. C., & Cao, H. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2526-0 · Cited by 320
Dielectrophoresis for manipulation of micro/nano particles in microfluidic systems
Zhang, C., Khoshmanesh, K., Mitchell, A., & Kalantar-zadeh, K. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2922-6 · Cited by 305
Introducing dielectrophoresis as a new force field for field-flow fractionation
Huang, Y., Wang, X. B., Becker, F. F., & Gascoyne, P. R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78144-x · Cited by 302
Self-citationMicrofluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Dielectrophoresis: Using Inhomogeneous AC Electrical Fields to Separate and Manipulate Cells
Pethig, R. (1996) · Critical Reviews in Biotechnology · doi:10.3109/07388559609147425 · Cited by 286
Self-citationMicrosample preparation by dielectrophoresis: isolation of malaria
Gascoyne, P., Mahidol, C., Ruchirawat, M., Satayavivad, J., Watcharasit, P., & Becker, F. F. (2002) · Lab on a Chip · doi:10.1039/b110990c · Cited by 278
Self-citationIsolation of Circulating Tumor Cells by Dielectrophoresis
Gascoyne, P., & Shim, S. (2014) · Cancers · doi:10.3390/cancers6010545 · Cited by 275
Self-citationRecent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
A 3-D microelectrode system for handling and caging single cells and particles
Müller, T., Gradl, G., Howitz, S., Shirley, S., Schnelle, T., & Fuhr, G. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00006-8 · Cited by 242
Size-based separation methods of circulating tumor cells
Hao, S.-J., Wan, Y., Xia, Y.-Q., Zou, X., & Zheng, S.-Y. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.01.002 · Cited by 241
“On the other hand, the cell volume can be directly measured with flow cytometry by determining the equivalent diffraction area and cross-sectional area of cells [50,51].”
BackgroundTime domain dielectric spectroscopy study of human cells
Polevaya, Y., Ermolina, I., Schlesinger, M., Ginzburg, B.-Z., & Feldman, Y. (1999) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(99)00072-3 · Cited by 234
Dielectrophoretic manipulation of rod-shaped viral particles
Morgan, H., & Green, N. G. (1997) · Journal of Electrostatics · doi:10.1016/s0304-3886(97)00159-9 · Cited by 232
Li, M., Li, W. H., Zhang, J., Alici, G., & Wen, W. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/6/063001 · Cited by 223
“Other research work on trapping cells and silica beads [98], concentrating embryonic stem cells (ESCs) [99], sorting nano-[100] and micro-particles [101], clones of mouse melanoma B16F10 cells [102], separating cancel cells from blood [103,104], separating dormant Mycobacterium smegmatis from live and dead M.”
Microfluidics and Circulating Tumor Cells
Dong, Y., Skelley, A. M., Merdek, K. D., Sprott, K. M., Jiang, C., Pierceall, W. E., Lin, J., Stocum, M., Carney, W. P., & Smirnov, D. A. (2013) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2012.09.004 · Cited by 219
Antibody-independent isolation of circulating tumor cells by continuous-flow dielectrophoresis
Shim, S., Stemke-Hale, K., Tsimberidou, A. M., Noshari, J., Anderson, T. E., & Gascoyne, P. R. C. (2013) · Biomicrofluidics · doi:10.1063/1.4774304 · Cited by 215
Self-citationElectrokinetic motion of particles and cells in microchannels
Kang, Y., & Li, D. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0408-7 · Cited by 210
Morgan, H., Izquierdo, A. G., Bakewell, D., Green, N. G., & Ramos, A. (2001) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/34/10/316 · Cited by 209
Unique Dielectric Properties Distinguish Stem Cells and Their Differentiated Progeny
Flanagan, L. A., Lu, J., Wang, L., Marchenko, S. A., Jeon, N. L., Lee, A. P., & Monuki, E. S. (2008) · Stem Cells · doi:10.1634/stemcells.2007-0810 · Cited by 207
Trapping Single Molecules by Dielectrophoresis
Hölzel, R., Calander, N., Chiragwandi, Z., Willander, M., & Bier, F. F. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.128102 · Cited by 197
Harouaka, R., Kang, Z., Zheng, S.-Y., & Cao, L. (2014) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2013.10.004 · Cited by 195
“Interdigitated gold electrodes were used by Becker, Gascoyne, and colleagues to isolate leukemia (Becker et al., 1994) and breast cancer cell lines (Becker et al., 1995) from spiked healthy donor blood.”
BackgroundMethodRare cell capture in microfluidic devices
Pratt, E. D., Huang, C., Hawkins, B. G., Gleghorn, J. P., & Kirby, B. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.09.012 · Cited by 194
“characterized the dielectric parameters of cultured breast cancer cells, lymphocytes, and erythrocytes using particle electrorotation techniques, and subsequently trapped the breast cancer cells from a suspension of diluted blood, demonstrating up to 95% purity in captured cancer cells (Becker et al., 1995).”
BackgroundDielectrophoretic separation of bacteria using a conductivity gradient
Markx, G. H., Dyda, P. A., & Pethig, R. (1996) · Journal of Biotechnology · doi:10.1016/0168-1656(96)01617-3 · Cited by 191
Self-citationDetection and isolation of circulating tumor cells: Principles and methods
Esmaeilsabzali, H., Beischlag, T. V., Cox, M. E., Parameswaran, A. M., & Park, E. J. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.08.016 · Cited by 189
“, one cancer cell mixed with 3 × 10 blood cells) have been reported (Becker et al., 1995; Gascoyne et al., 1997; Yang et al., 1999).”
BackgroundSeparation of tumor cells with dielectrophoresis-based microfluidic chip
Alshareef, M., Metrakos, N., Juarez Perez, E., Azer, F., Yang, F., Yang, X., & Wang, G. (2013) · Biomicrofluidics · doi:10.1063/1.4774312 · Cited by 188
Antfolk, M., & Laurell, T. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.02.017 · Cited by 184
Gascoyne, P. R. C., Shim, S., Noshari, J., Becker, F. F., & Stemke‐Hale, K. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200496 · Cited by 183
Self-citationManipulation and trapping of sub-micron bioparticles using dielectrophoresis
Green, N. G., Morgan, H., & Milner, J. J. (1997) · Journal of Biochemical and Biophysical Methods · doi:10.1016/s0165-022x(97)00033-x · Cited by 181
Separation of Polystyrene Microbeads Using Dielectrophoretic/Gravitational Field-Flow-Fractionation
Wang, X.-B., Vykoukal, J., Becker, F. F., & Gascoyne, P. R. C. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77975-5 · Cited by 175
Self-citationEnrichment and single-cell analysis of circulating tumor cells
Song, Y., Tian, T., Shi, Y., Liu, W., Zou, Y., Khajvand, T., Wang, S., Zhu, Z., & Yang, C. (2017) · Chemical Science · doi:10.1039/c6sc04671a · Cited by 167
Microfluidic technologies for circulating tumor cell isolation
Cho, H., Kim, J., Song, H., Sohn, K. Y., Jeon, M., & Han, K.-H. (2018) · The Analyst · doi:10.1039/c7an01979c · Cited by 167
Negative DEP traps for single cell immobilisation
Thomas, R. S., Morgan, H., & Green, N. G. (2009) · Lab on a Chip · doi:10.1039/b819267g · Cited by 166
Polymer-Based Microfluidic Devices for Pharmacy, Biology and Tissue Engineering
Alrifaiy, A., Lindahl, O. A., & Ramser, K. (2012) · Polymers · doi:10.3390/polym4031349 · Cited by 161
“variety of biological cells such as bacteria, yeast and mammalian cells [177–192].”
BackgroundBroadband dielectric spectroscopy on human blood
Wolf, M., Gulich, R., Lunkenheimer, P., & Loidl, A. (2011) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2011.05.012 · Cited by 161
Separation and characterization of microplastic and nanoplastic particles in marine environment
Zhao, K., Wei, Y., Dong, J., Zhao, P., Wang, Y., Pan, X., & Wang, J. (2022) · Environmental Pollution · doi:10.1016/j.envpol.2021.118773 · Cited by 159
Continuous dielectrophoretic cell separation microfluidic device
Li, Y., Dalton, C., Crabtree, H. J., Nilsson, G., & Kaler, K. V. I. S. (2007) · Lab Chip · doi:10.1039/b613344d · Cited by 158
Metadata
- Authors
- Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1995-01-31
- Volume
- 92
- Issue
- 3
- Pages
- 860-864
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2060040620
- Cited by
- 680
- References
- 12
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.