The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Crystal Structures of the GCaMP Calcium Sensor Reveal the Mechanism of Fluorescence Signal Change and Aid Rational Design
Open accessAbstract
The genetically encoded calcium indicator GCaMP2 shows promise for neural network activity imaging, but is currently limited by low signal-to-noise ratio. We describe x-ray crystal structures as well as solution biophysical and spectroscopic characterization of GCaMP2 in the calcium-free dark state, and in two calcium-bound bright states: a monomeric form that dominates at intracellular concentrations observed during imaging experiments and an unexpected domain-swapped dimer with decreased fluorescence. This series of structures provides insight into the mechanism of Ca2+-induced fluorescence change. Upon calcium binding, the calmodulin (CaM) domain wraps around the M13 peptide, creating a new domain interface between CaM and the circularly permuted enhanced green fluorescent protein domain. Residues from CaM alter the chemical environment of the circularly permuted enhanced green fluorescent protein chromophore and, together with flexible inter-domain linkers, block solvent access to the chromophore. Guided by the crystal structures, we engineered a series of GCaMP2 point mutants to probe the mechanism of GCaMP2 function and characterized one mutant with significantly improved signal-to-noise. The mutation is located at a domain interface and its effect on sensor function could not have been predicted in the absence of structural data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
[20] Processing of X-ray diffraction data collected in oscillation mode
Otwinowski, Z., & Minor, W. (1997) · Methods in Enzymology · doi:10.1016/s0076-6879(97)76066-x · Cited by 33,475
Coot : model-building tools for molecular graphics
Emsley, P., & Cowtan, K. (2004) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444904019158 · Cited by 30,571
Phaser crystallographic software
McCoy, A. J., Grosse-Kunstleve, R. W., Adams, P. D., Winn, M. D., Storoni, L. C., & Read, R. J. (2007) · Journal of Applied Crystallography · doi:10.1107/s0021889807021206 · Cited by 20,612
The CCP4 suite: programs for protein crystallography
Collaborative Computational Project, N. 4. (1994) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444994003112 · Cited by 17,270
Refinement of Macromolecular Structures by the Maximum-Likelihood Method
Murshudov, G. N., Vagin, A. A., & Dodson, E. J. (1997) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444996012255 · Cited by 14,742
Protein production by auto-induction in high-density shaking cultures
Studier, F. W. (2005) · Protein Expression and Purification · doi:10.1016/j.pep.2005.01.016 · Cited by 5,931
Schuck, P. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76713-0 · Cited by 3,868
Crystal Structure of the Aequorea victoria Green Fluorescent Protein
Ormö, M., Cubitt, A. B., Kallio, K., Gross, L. A., Tsien, R. Y., & Remington, S. J. (1996) · Science · doi:10.1126/science.273.5280.1392 · Cited by 2,242
A high signal-to-noise Ca2+ probe composed of a single green fluorescent protein
Nakai, J., Ohkura, M., & Imoto, K. (2001) · Nature Biotechnology · doi:10.1038/84397 · Cited by 1,616
The molecular structure of green fluorescent protein
Yang, F., Moss, L. G., & Phillips, G. N. (1996) · Nature Biotechnology · doi:10.1038/nbt1096-1246 · Cited by 1,576
Cited by
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Self-citationImaging neural activity in worms, flies and mice with improved GCaMP calcium indicators
Tian, L., Hires, S. A., Mao, T., Huber, D., Chiappe, M. E., Chalasani, S. H., Petreanu, L., Akerboom, J., McKinney, S. A., Schreiter, E. R., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1398 · Cited by 1,967
Self-citationAn Expanded Palette of Genetically Encoded Ca 2+ Indicators
Zhao, Y., Araki, S., Wu, J., Teramoto, T., Chang, Y.-F., Nakano, M., Abdelfattah, A. S., Fujiwara, M., Ishihara, T., Nagai, T., et al. (2011) · Science · doi:10.1126/science.1208592 · Cited by 1,260
Optimization of a GCaMP Calcium Indicator for Neural Activity Imaging
Akerboom, J., Chen, T.-W., Wardill, T. J., Tian, L., Marvin, J. S., Mutlu, S., Calderón, N. C., Esposti, F., Borghuis, B. G., Sun, X. R., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2601-12.2012 · Cited by 1,223
Self-citationHigh-performance calcium sensors for imaging activity in neuronal populations and microcompartments
Dana, H., Sun, Y., Mohar, B., Hulse, B. K., Kerlin, A. M., Hasseman, J. P., Tsegaye, G., Tsang, A., Wong, A., Patel, R., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0435-6 · Cited by 1,182
Self-citationSensitive red protein calcium indicators for imaging neural activity
Dana, H., Mohar, B., Sun, Y., Narayan, S., Gordus, A., Hasseman, J. P., Tsegaye, G., Holt, G. T., Hu, A., Walpita, D., et al. (2016) · eLife · doi:10.7554/elife.12727 · Cited by 1,034
Self-citationFast and sensitive GCaMP calcium indicators for imaging neural populations
Zhang, Y., Rózsa, M., Liang, Y., Bushey, D., Wei, Z., Zheng, J., Reep, D., Broussard, G. J., Tsang, A., Tsegaye, G., et al. (2023) · Nature · doi:10.1038/s41586-023-05828-9 · Cited by 870
Self-citationAkerboom, J., Carreras Calderón, N., Tian, L., Wabnig, S., Prigge, M., Tolö, J., Gordus, A., Orger, M. B., Severi, K. E., Macklin, J. J., et al. (2013) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2013.00002 · Cited by 719
Self-citationThe Growing and Glowing Toolbox of Fluorescent and Photoactive Proteins
Rodriguez, E. A., Campbell, R. E., Lin, J. Y., Lin, M. Z., Miyawaki, A., Palmer, A. E., Shu, X., Zhang, J., & Tsien, R. Y. (2017) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2016.09.010 · Cited by 633
Modulation of protein properties in living cells using nanobodies
Kirchhofer, A., Helma, J., Schmidthals, K., Frauer, C., Cui, S., Karcher, A., Pellis, M., Muyldermans, S., Casas-Delucchi, C. S., Cardoso, M. C., et al. (2010) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.1727 · Cited by 586
A genetically encoded fluorescent sensor for rapid and specific in vivo detection of norepinephrine
Feng, J., Zhang, C., Lischinsky, J. E., Jing, M., Zhou, J., Wang, H., Zhang, Y., Dong, A., Wu, Z., Wu, H., et al. (2019) · Neuron · doi:10.1016/j.neuron.2019.02.037 · Cited by 545
Self-citationImaging cytosolic NADH-NAD(+) redox state with a genetically encoded fluorescent biosensor
Hung, Y. P., Albeck, J. G., Tantama, M., & Yellen, G. (2011) · Cell Metabolism · doi:10.1016/j.cmet.2011.08.012 · Cited by 509
Labeling of active neural circuits in vivo with designed calcium integrators
Fosque, B. F., Sun, Y., Dana, H., Yang, C.-T., Ohyama, T., Tadross, M. R., Patel, R., Zlatic, M., Kim, D. S., Ahrens, M. B., et al. (2015) · Science · doi:10.1126/science.1260922 · Cited by 458
Self-citationA Critical and Comparative Review of Fluorescent Tools for Live-Cell Imaging
Specht, E. A., Braselmann, E., & Palmer, A. E. (2017) · Annual Review of Physiology · doi:10.1146/annurev-physiol-022516-034055 · Cited by 444
Optimized ratiometric calcium sensors for functional in vivo imaging of neurons and T lymphocytes
Thestrup, T., Litzlbauer, J., Bartholomäus, I., Mues, M., Russo, L., Dana, H., Kovalchuk, Y., Liang, Y., Kalamakis, G., Laukat, Y., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2773 · Cited by 366
Genetically Encodable Fluorescent Biosensors for Tracking Signaling Dynamics in Living Cells
Newman, R. H., Fosbrink, M. D., & Zhang, J. (2011) · Chemical Reviews · doi:10.1021/cr100002u · Cited by 353
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Genetically encoded biosensors based on engineered fluorescent proteins
Frommer, W. B., Davidson, M. W., & Campbell, R. E. (2009) · Chemical Society Reviews · doi:10.1039/b907749a · Cited by 319
Ghosh-Roy, A., Wu, Z., Goncharov, A., Jin, Y., & Chisholm, A. D. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.5464-09.2010 · Cited by 303
Ohkura, M., Sasaki, T., Sadakari, J., Gengyo-Ando, K., Kagawa-Nagamura, Y., Kobayashi, C., Ikegaya, Y., & Nakai, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051286 · Cited by 268
Rational design of a high-affinity, fast, red calcium indicator R-CaMP2
Inoue, M., Takeuchi, A., Horigane, S.-I., Ohkura, M., Gengyo-Ando, K., Fujii, H., Kamijo, S., Takemoto-Kimura, S., Kano, M., Nakai, J., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3185 · Cited by 256
Tools for Resolving Functional Activity and Connectivity within Intact Neural Circuits
Jennings, J. H., & Stuber, G. D. (2014) · Current Biology · doi:10.1016/j.cub.2013.11.042 · Cited by 54
Seeing glutamate at central synapses
Hao, Y., & Plested, A. J. R. (2022) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2022.109531 · Cited by 18
Berksoz, M., & Atilgan, C. (2024) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.26688 · Cited by 8
“Chromophores are labeled and colored according to the color emitted in their fluorescent states.”
BackgroundMethodPapadopoulos, A., Anlauf, M. T., Reiners, J., Paik, S.-H., Krüger, A., Lückel, B., Bott, M., Drepper, T., Frunzke, J., Gohlke, H., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.5c02481 · Cited by 5
Papadopoulos, A., Anlauf, M. T., Reiners, J., Paik, S.-H., Krüger, A., Lückel, B., Bott, M., Drepper, T., Frunzke, J., Gohlke, H., et al. (2025) · doi:10.1101/2025.07.16.665043
Metadata
- Authors
- Akerboom, J., Rivera, J. D. V., Guilbe, M. M. R., Malavé, E. C. A., Hernandez, H. H., Tian, L., Hires, S. A., Marvin, J. S., Looger, L. L., & Schreiter, E. R.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 284
- Issue
- 10
- Pages
- 6455-6464
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1967642375
- Cited by
- 285
- References
- 34
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.