The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Comparison of Label-free Methods for Quantifying Human Proteins by Shotgun Proteomics
Open accessAbstract
Measurements of mass spectral peak intensities and spectral counts are promising methods for quantifying protein abundance changes in shotgun proteomic analyses. We describe Serac, software developed to evaluate the ability of each method to quantify relative changes in protein abundance. Dynamic range and linearity using a three-dimensional ion trap were tested using standard proteins spiked into a complex sample. Linearity and good agreement between observed versus expected protein ratios were obtained after normalization and background subtraction of peak area intensity measurements and correction of spectral counts to eliminate discontinuity in ratio estimates. Peak intensity values useful for protein quantitation ranged from 10(7) to 10(11) counts with no obvious saturation effect, and proteins in replicate samples showed variations of less than 2-fold within the 95% range (+/-2sigma) when >or=3 peptides/protein were shared between samples. Protein ratios were determined with high confidence from spectral counts when maximum spectral counts were >or=4 spectra/protein, and replicates showed equivalent measurements well within 95% confidence limits. In further tests, complex samples were separated by gel exclusion chromatography, quantifying changes in protein abundance between different fractions. Linear behavior of peak area intensity measurements was obtained for peptides from proteins in different fractions. Protein ratios determined by spectral counting agreed well with those determined from peak area intensity measurements, and both agreed with independent measurements based on gel staining intensities. Overall spectral counting proved to be a more sensitive method for detecting proteins that undergo changes in abundance, whereas peak area intensity measurements yielded more accurate estimates of protein ratios. Finally these methods were used to analyze differential changes in protein expression in human erythroleukemia K562 cells stimulated under conditions that promote cell differentiation by mitogen-activated protein kinase pathway activation. Protein changes identified with p<0.1 showed good correlations with parallel measurements of changes in mRNA expression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biometry: The Principles and Practice of Statistics in Biological Research
Sokal, R. R., & Rohlf, F. J. (1969) · Cited by 20,963
Bioconductor: open software development for computational biology and bioinformatics
Gentleman, R. C., Carey, V. J., Bates, D. M., Bolstad, B., Dettling, M., Dudoit, S., Ellis, B., Gautier, L., Ge, Y., Gentry, J., et al. (2004) · Genome Biology · doi:10.1186/gb-2004-5-10-r80 · Cited by 12,172
Exploration, normalization, and summaries of high density oligonucleotide array probe level data
Irizarry, R. A. (2003) · Biostatistics · doi:10.1093/biostatistics/4.2.249 · Cited by 10,603
Biometry. The Principles and Practice of Statistics in Biological Research
Fienberg, S. E., Sokal, R. R., Rohlf, F. J., Rohlf, F. J., & Sokal, R. R. (1970) · Biometrics · doi:10.2307/2529087 · Cited by 9,364
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 4×
“DTA files were generated from the MS/MS spectra by TurboSequest and searched by Sequest or concatenated into a Mascot Generic File for searching with Mascot; searches used the International Protein Index (IPI) database from European Bioinformatics Institute (version 2.18 for Sample 2; version 3.0, November 2004 for Sa…”
MethodInfluentialQuantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Global analysis of protein expression in yeast
Ghaemmaghami, S., Huh, W.-K., Bower, K., Howson, R. W., Belle, A., Dephoure, N., O'Shea, E. K., & Weissman, J. S. (2003) · Nature · doi:10.1038/nature02046 · Cited by 3,750
A Model for Random Sampling and Estimation of Relative Protein Abundance in Shotgun Proteomics
Liu, H., Sadygov, R. G., & Yates, J. R. (2004) · Analytical Chemistry · doi:10.1021/ac0498563 · Cited by 2,500
Direct analysis of protein complexes using mass spectrometry
Link, A. J., Eng, J., Schieltz, D. M., Carmack, E., Mize, G. J., Morris, D. R., Garvik, B. M., & Yates, J. R. (1999) · Nature Biotechnology · doi:10.1038/10890 · Cited by 2,237
An Automated Multidimensional Protein Identification Technology for Shotgun Proteomics
Wolters, D. A., Washburn, M. P., & Yates, J. R. (2001) · Analytical Chemistry · doi:10.1021/ac010617e · Cited by 1,819
Yates, J. R., Eng, J. K., McCormack, A. L., & Schieltz, D. (1995) · Analytical Chemistry · doi:10.1021/ac00104a020 · Cited by 1,253
Proteolytic 18O Labeling for Comparative Proteomics: Model Studies with Two Serotypes of Adenovirus
Yao, X., Freas, A., Ramirez, J., Demirev, P. A., & Fenselau, C. (2001) · Analytical Chemistry · doi:10.1021/ac001404c · Cited by 759
limmaGUI: A graphical user interface for linear modeling of microarray data
Wettenhall, J. M., & Smyth, G. K. (2004) · Bioinformatics · doi:10.1093/bioinformatics/bth449 · Cited by 722
The International Protein Index: An integrated database for proteomics experiments
Kersey, P. J., Duarte, J., Williams, A., Karavidopoulou, Y., Birney, E., & Apweiler, R. (2004) · PROTEOMICS · doi:10.1002/pmic.200300721 · Cited by 693
Griffin, T. J., Gygi, S. P., Ideker, T., Rist, B., Eng, J., Hood, L., & Aebersold, R. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200001-mcp200 · Cited by 663
Wang, W., Zhou, H., Lin, H., Roy, S., Shaler, T. A., Hill, L. R., Norton, S., Kumar, P., Anderle, M., & Becker, C. H. (2003) · Analytical Chemistry · doi:10.1021/ac026468x · Cited by 653
McCormack, A. L., Schieltz, D. M., Goode, B., Yang, S., Barnes, G., Drubin, D., & Yates, J. R. (1997) · Analytical Chemistry · doi:10.1021/ac960799q · Cited by 523
Rorabacher, D. B. (1991) · Analytical Chemistry · doi:10.1021/ac00002a010 · Cited by 446
Chelius, D., & Bondarenko, P. V. (2002) · Journal of Proteome Research · doi:10.1021/pr025517j · Cited by 423
Bondarenko, P. V., Chelius, D., & Shaler, T. A. (2002) · Analytical Chemistry · doi:10.1021/ac0256991 · Cited by 387
Quantitative proteome analysis by solid-phase isotope tagging and mass spectrometry
Zhou, H., Ranish, J. A., Watts, J. D., & Aebersold, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0502-512 · Cited by 384
Li, X.-J., Zhang, H., Ranish, J. A., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac034633i · Cited by 342
Spahr, C. S., Davis, M. T., McGinley, M. D., Robinson, J. H., Bures, E. J., Beierle, J., Mort, J., Courchesne, P. L., Chen, K., Wahl, R. C., et al. (2001) · PROTEOMICS · doi:10.1002/1615-9861(200101)1:1<93::aid-prot93>3.0.co;2-3 · Cited by 309
Gygi, S. P., Rist, B., Griffin, T. J., Eng, J., & Aebersold, R. (2002) · Journal of Proteome Research · doi:10.1021/pr015509n · Cited by 307
A Correlation Algorithm for the Automated Quantitative Analysis of Shotgun Proteomics Data
MacCoss, M. J., Wu, C. C., Liu, H., Sadygov, R., & Yates, J. R. (2003) · Analytical Chemistry · doi:10.1021/ac034790h · Cited by 278
Tang, K., Page, J. S., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.034 · Cited by 262
Lewis, T. S., Hunt, J. B., Aveline, L. D., Jonscher, K. R., Louie, D. F., Yeh, J. M., Nahreini, T. S., Resing, K. A., & Ahn, N. G. (2000) · Molecular Cell · doi:10.1016/s1097-2765(00)00132-5 · Cited by 242
Self-citationWhalen, A. M., Galasinski, S. C., Shapiro, P. S., Nahreini, T. S., & Ahn, N. G. (1997) · Molecular and Cellular Biology · doi:10.1128/mcb.17.4.1947 · Cited by 231
Self-citationImproving Reproducibility and Sensitivity in Identifying Human Proteins by Shotgun Proteomics
Resing, K. A., Meyer-Arendt, K., Mendoza, A. M., Aveline-Wolf, L. D., Jonscher, K. R., Pierce, K. G., Old, W. M., Cheung, H. T., Russell, S., Wattawa, J. L., et al. (2004) · Analytical Chemistry · doi:10.1021/ac035229m · Cited by 228
Self-citationApproaching complete peroxisome characterization by gas-phase fractionation
Yi, E. C., Marelli, M., Lee, H., Purvine, S. O., Aebersold, R., Aitchison, J. D., & Goodlett, D. R. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200209)23:18<3205::aid-elps3205>3.0.co;2-y · Cited by 183
Anderle, M., Roy, S., Lin, H., Becker, C. H., & Joho, K. E. (2004) · Bioinformatics · doi:10.1093/bioinformatics/bth446 · Cited by 135
Davis, M. T., Spahr, C. S., McGinley, M. D., Robinson, J. H., Bures, E. J., Beierle, J., Mort, J., Yu, W., Luethy, R., & Patterson, S. D. (2001) · PROTEOMICS · Cited by 131
Statistical modeling of sequencing errors in SAGE libraries
Beißbarth, T., Hyde, L., Smyth, G. K., Job, C., Boon, W., Tan, S., Scott, H. S., & Speed, T. P. (2004) · Bioinformatics · doi:10.1093/bioinformatics/bth924 · Cited by 116
DBParser: Web-Based Software for Shotgun Proteomic Data Analyses
Yang, X., Dondeti, V. R., Dezube, R., Maynard, D., Geer, L. Y., Epstein, J., Chen, X., Markey, S. P., & Kowalak, J. A. (2004) · Journal of Proteome Research · doi:10.1021/pr049920x · Cited by 93
Testing for differentially expressed genes with microarray data
Tsai, C. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng052 · Cited by 78
Abundance Ratio-Dependent Proteomic Analysis by Mass Spectrometry
Griffin, T. J., Lock, C. M., Li, X., Patel, A. R., Chervetsova, I., Lee, H., Wright, M. E., Ranish, J. A., Chen, S. S., & Aebersold, R. H. (2003) · Analytical Chemistry · doi:10.1021/ac026127j · Cited by 63
Sevinsky, J. R., Whalen, A. M., & Ahn, N. G. (2004) · Molecular and Cellular Biology · doi:10.1128/mcb.24.10.4534-4545.2004 · Cited by 54
Self-citation
Cited by
Cox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180
On the Dependency of Cellular Protein Levels on mRNA Abundance
Liu, Y., Beyer, A., & Aebersold, R. (2016) · Cell · doi:10.1016/j.cell.2016.03.014 · Cited by 3,221
Global Survey of Phosphotyrosine Signaling Identifies Oncogenic Kinases in Lung Cancer
Rikova, K., Guo, A., Zeng, Q., Possemato, A., Yu, J., Haack, H., Nardone, J., Lee, K., Reeves, C., Li, Y., et al. (2007) · Cell · doi:10.1016/j.cell.2007.11.025 · Cited by 2,317
Quantitative mass spectrometry in proteomics: a critical review
Bantscheff, M., Schirle, M., Sweetman, G., Rick, J., & Kuster, B. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1486-6 · Cited by 1,669
Proteogenomic characterization of human colon and rectal cancer
CPTAC, T. N., Zhang, B., Wang, J., Wang, X., Zhu, J., Liu, Q., Shi, Z., Chambers, M. C., Zimmerman, L. J., Shaddox, K. F., et al. (2014) · Nature · doi:10.1038/nature13438 · Cited by 1,462
Metadata
- Authors
- Old, W. M., Meyer-Arendt, K., Aveline-Wolf, L., Pierce, K. G., Mendoza, A., Sevinsky, J. R., Resing, K. A., & Ahn, N. G.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2005-10
- Volume
- 4
- Issue
- 10
- Pages
- 1487-1502
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2160110467
- Cited by
- 1,206
- References
- 38
- FWCI
- 25.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.