An Automated and Multiplexed Method for High Throughput Peptide Immunoaffinity Enrichment and Multiple Reaction Monitoring Mass Spectrometry-based Quantification of Protein Biomarkers
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
There is an urgent need for quantitative assays in verifying and validating the large numbers of protein biomarker candidates produced in modern "-omics" experiments. Stable isotope standards with capture by anti-peptide antibodies (SISCAPA) has shown tremendous potential to meet this need by combining peptide immunoaffinity enrichment with quantitative mass spectrometry. In this study, we describe three significant advances to the SISCAPA technique. First, we develop a method for an automated magnetic bead-based platform capable of high throughput processing. Second, we implement the automated method in a multiplexed SISCAPA assay (nine targets in one assay) and assess the performance characteristics of the multiplexed assay. Using the automated, multiplexed platform, we demonstrate detection limits in the physiologically relevant ng/ml range (from 10 microl of plasma) with sufficient precision (median coefficient of variation, 12.6%) for quantifying biomarkers. Third, we demonstrate that enrichment of peptides from larger volumes of plasma (1 ml) can extend the limits of detection to the low pg/ml range of protein concentration. The method is generally applicable to any protein or biological specimen of interest and holds great promise for analyzing large numbers of biomarker candidates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Self-citationAnderson, N. L., Anderson, N. G., Haines, L. R., Hardie, D. B., Olafson, R. W., & Pearson, T. W. (2004) · Journal of Proteome Research · doi:10.1021/pr034086h · Cited by 804
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Insights from genomic profiling of transcription factors
Farnham, P. J. (2009) · Nature Reviews Genetics · doi:10.1038/nrg2636 · Cited by 519 · cited 1×
“through nucleic acid arrays) has had a major impact on biology (13, 14), and it is reasonable to expect that having highly multiplexed, quantitative assays for a large suite of human protein forms would have an equal or greater impact (15).”
BackgroundKuzyk, M. A., Smith, D., Yang, J., Cross, T. J., Jackson, A. M., Hardie, D. B., Anderson, N. L., & Borchers, C. H. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800540-mcp200 · Cited by 515
Peng, J., Kim, M. J., Cheng, D., Duong, D. M., Gygi, S. P., & Sheng, M. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m400103200 · Cited by 473
Yin, H., Killeen, K., Brennen, R., Sobek, D., Werlich, M., & van de Goor, T. (2005) · Analytical Chemistry · doi:10.1021/ac049068d · Cited by 362
High Sensitivity Detection of Plasma Proteins by Multiple Reaction Monitoring of N-Glycosites
Stahl-Zeng, J., Lange, V., Ossola, R., Eckhardt, K., Krek, W., Aebersold, R., & Domon, B. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700132-mcp200 · Cited by 361
Hoofnagle, A. N., Becker, J. O., Wener, M. H., & Heinecke, J. W. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.109652 · Cited by 314 · cited 1×
“To date, individual SISCAPA assays have been successfully configured to a number of analytes (4–9), and up to three peptides have been enriched simultaneously (7, 8).”
Cited by
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
Mass spectrometry in high-throughput proteomics: ready for the big time
Nilsson, T., Mann, M., Aebersold, R., Yates, J. R., Bairoch, A., & Bergeron, J. J. M. (2010) · Nature Methods · doi:10.1038/nmeth0910-681 · Cited by 470
Mass spectrometry-based proteomics: existing capabilities and future directions
Angel, T. E., Aryal, U. K., Hengel, S. M., Baker, E. S., Kelly, R. T., Robinson, E. W., & Smith, R. D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15331a · Cited by 441
A targeted proteomics–based pipeline for verification of biomarkers in plasma
Whiteaker, J. R., Lin, C., Kennedy, J., Hou, L., Trute, M., Sokal, I., Yan, P., Schoenherr, R. M., Zhao, L., Voytovich, U. J., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1900 · Cited by 364
Self-citationSelected reaction monitoring applied to proteomics
Gallien, S., Duriez, E., & Domon, B. (2011) · Journal of Mass Spectrometry · doi:10.1002/jms.1895 · Cited by 286
The use of mass spectrometry to analyze dried blood spots
Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21441 · Cited by 262
Advances in human proteomics at high scale with the SOMAscan proteomics platform
Gold, L., Walker, J. J., Wilcox, S. K., & Williams, S. (2012) · New Biotechnology · doi:10.1016/j.nbt.2011.11.016 · Cited by 261
Advancing the sensitivity of selected reaction monitoring‐based targeted quantitative proteomics
Shi, T., Su, D., Liu, T., Tang, K., Camp, D. G., Qian, W., & Smith, R. D. (2012) · PROTEOMICS · doi:10.1002/pmic.201100436 · Cited by 245
Bioanalytical LC–MS/MS of protein-based biopharmaceuticals
van den Broek, I., Niessen, W. M. A., & van Dongen, W. D. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.04.030 · Cited by 232
Schwenk, J. M., Omenn, G. S., Sun, Z., Campbell, D. S., Baker, M. S., Overall, C. M., Aebersold, R., Moritz, R. L., & Deutsch, E. W. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00467 · Cited by 230
Shi, T., Fillmore, T. L., Sun, X., Zhao, R., Schepmoes, A. A., Hossain, M., Xie, F., Wu, S., Kim, J.-S., Jones, N., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204366109 · Cited by 224
Abbatiello, S. E., Schilling, B., Mani, D. R., Zimmerman, L. J., Hall, S. C., MacLean, B., Albertolle, M., Allen, S., Burgess, M., Cusack, M. P., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.047050 · Cited by 215
Self-citationTebani, A., Afonso, C., Marret, S., & Bekri, S. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17091555 · Cited by 212
“One approach is immunocapture enrichment of low-abundance proteins prior to their MS detection [123] at the expense of additional steps in the analytical process, which may affect the throughput.”
BackgroundMRM‐based multiplexed quantitation of 67 putative cardiovascular disease biomarkers in human plasma
Domanski, D., Percy, A. J., Yang, J., Chambers, A. G., Hill, J. S., Freue, G. V. C., & Borchers, C. H. (2012) · PROTEOMICS · doi:10.1002/pmic.201100568 · Cited by 205
“This level of sensitivity is expected from proteomic platforms using depletion of abundant plasma proteins [31, 41] or immunoaffinity enrichment [3, 42–44].”
BackgroundQuantitative measurements of N‐linked glycoproteins in human plasma by SWATH‐MS
Liu, Y., Hüttenhain, R., Surinova, S., Gillet, L. C., Mouritsen, J., Brunner, R., Navarro, P., & Aebersold, R. (2013) · PROTEOMICS · doi:10.1002/pmic.201200417 · Cited by 204
“This difference might be attributed to the increased effect of sample matrix near to the LOQ [26].”
BackgroundKuhn, E., Whiteaker, J. R., Mani, D. R., Jackson, A. M., Zhao, L., Pope, M. E., Smith, D., Rivera, K. D., Anderson, N. L., Skates, S. J., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.013854 · Cited by 183
“potentially novel protein biomarkers in cancer (14, 15, 22) and”
BackgroundMethodSelf-citationBauer, M., Chicca, A., Tamborrini, M., Eisen, D., Lerner, R., Lutz, B., Poetz, O., Pluschke, G., & Gertsch, J. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.382481 · Cited by 168
“fication of single Pepcans using synthetic stable isotope-labeled peptide standards together with multiple reaction monitoring (25, 60, 61).”
MethodAgger, S. A., Marney, L. C., & Hoofnagle, A. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.152264 · Cited by 143
Hoofnagle, A. N., Becker, J. O., Oda, M. N., Cavigiolio, G., Mayer, P., & Vaisar, T. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.173856 · Cited by 140
Guo, B., Chen, B., Liu, A., Zhu, W., & Yao, S. (2012) · Current Drug Metabolism · doi:10.2174/138920012803341401 · Cited by 80
Lassman, M. E., McLaughlin, T. M., Somers, E. P., Stefanni, A. C., Chen, Z., Murphy, B. A., Bierilo, K. K., Flattery, A. M., Wong, K. K., Castro‐Perez, J. M., et al. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5296 · Cited by 51
Metadata
- Authors
- Whiteaker, J. R., Zhao, L., Anderson, L., & Paulovich, A. G.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 9
- Issue
- 1
- Pages
- 184-196
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2047322941
- Cited by
- 323
- References
- 26
- FWCI
- 13.39
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.