Tissue Profiling by Mass Spectrometry
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) has become a valuable tool to address a broad range of questions in many areas of biomedical research. One such application allows spectra to be obtained directly from intact tissues, termed "profiling" (low resolution) and "imaging" (high resolution). In light of the fact that MALDI tissue profiling allows over a thousand peptides and proteins to be rapidly detected from a variety of tissues, its application to disease processes is of special interest. For example, protein profiles from tumors may allow accurate prediction of tumor behavior, diagnosis, and prognosis and uncover etiologies underlying idiopathic diseases. MALDI MS, in conjunction with laser capture microdissection, is able to produce protein expression profiles from a relatively small number of cells from specific regions of heterogeneous tissue architectures. Imaging mass spectrometry enables the investigator to assess the spatial distribution of proteins, drugs, and their metabolites in intact tissues. This article provides an overview of several tissue profiling and imaging applications performed by MALDI MS, including sample preparation, matrix selection and application, histological staining prior to MALDI analysis, tissue profiling, imaging, and data analysis. Several applications represent direct translation of this technology to clinically relevant problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234 · cited 1×
“Other examples of direct analysis of peptides and proteins from intact tissues include the detection of proteins from rat pituitary ( 3 ), mouse brain (4), human brain tumor xenografts (4), and mouse prostate (5).”
BackgroundSelf-citationStoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172
Self-citationSchwartz, S. A., Reyzer, M. L., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.505 · Cited by 646
Self-citationProteomic patterns of tumour subsets in non-small-cell lung cancer
Yanagisawa, K., Shyr, Y., Xu, B. J., Massion, P. P., Larsen, P. H., White, B. C., Roberts, J. R., Edgerton, M., Gonzalez, A., Nadaf, S., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14068-8 · Cited by 602
Self-citationReyzer, M. L., Hsieh, Y., Ng, K., Korfmacher, W. A., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.525 · Cited by 371
Self-citationIntegrating Histology and Imaging Mass Spectrometry
Chaurand, P., Schwartz, S. A., Billheimer, D., Xu, B. J., Crecelius, A., & Caprioli, R. M. (2004) · Analytical Chemistry · doi:10.1021/ac0351264 · Cited by 365
Self-citationTodd, P. J., Schaaff, T. G., Chaurand, P., & Caprioli, R. M. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.153 · Cited by 298
Self-citationDirect Profiling of Proteins in Biological Tissue Sections by MALDI Mass Spectrometry
Chaurand, P., Stoeckli, M., & Caprioli, R. M. (1999) · Analytical Chemistry · doi:10.1021/ac990781q · Cited by 282
Self-citationProteomics in Diagnostic Pathology
Chaurand, P., Sanders, M. E., Jensen, R. A., & Caprioli, R. M. (2004) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63367-6 · Cited by 253
Self-citationMolecular imaging of amyloid β peptides in mouse brain sections using mass spectrometry
Stoeckli, M., Staab, D., Staufenbiel, M., Wiederhold, K.-H., & Signor, L. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00386-x · Cited by 225
Cited by
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Self-citationMass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Clathrate nanostructures for mass spectrometry
Northen, T. R., Yanes, O., Northen, M. T., Marrinucci, D., Uritboonthai, W., Apon, J., Golledge, S. L., Nordström, A., & Siuzdak, G. (2007) · Nature · doi:10.1038/nature06195 · Cited by 480
Ambient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
MALDI imaging mass spectrometry for direct tissue analysis: a new frontier for molecular histology
Walch, A., Rauser, S., Deininger, S.-O., & Höfler, H. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0469-9 · Cited by 334
Guo, L., Panderi, I., Yan, D. D., Szulak, K., Li, Y., Chen, Y.-T., Ma, H., Niesen, D. B., Seeram, N., Ahmed, A., et al. (2013) · ACS Nano · doi:10.1021/nn403202w · Cited by 316
Advances in Imaging Secondary Ion Mass Spectrometry for Biological Samples
Boxer, S. G., Kraft, M. L., & Weber, P. K. (2009) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.050708.133634 · Cited by 308
Methods for samples preparation in proteomic research
Bodzon-Kulakowska, A., Bierczynska-Krzysik, A., Dylag, T., Drabik, A., Suder, P., Noga, M., Jarzebinska, J., & Silberring, J. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.10.040 · Cited by 254
Porcine Models of Cutaneous Wound Healing
Seaton, M., Hocking, A., & Gibran, N. S. (2015) · ILAR Journal · doi:10.1093/ilar/ilv016 · Cited by 249
Sumner, L. W., Lei, Z., Nikolau, B. J., & Saito, K. (2015) · Natural Product Reports · doi:10.1039/c4np00072b · Cited by 233
Identification of Biological Tissues by Rapid Evaporative Ionization Mass Spectrometry
Balog, J., Szaniszlo, T., Schaefer, K.-C., Denes, J., Lopata, A., Godorhazy, L., Szalay, D., Balogh, L., Sasi-Szabo, L., Toth, M., et al. (2010) · Analytical Chemistry · doi:10.1021/ac101283x · Cited by 231
Cazares, L. H., Troyer, D., Mendrinos, S., Lance, R. A., Nyalwidhe, J. O., Beydoun, H. A., Clements, M. A., Drake, R. R., & Semmes, O. J. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-2892 · Cited by 194
Atmospheric Pressure Molecular Imaging by Infrared MALDI Mass Spectrometry
Li, Y., Shrestha, B., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac061577n · Cited by 193
Cornett, D. S., Mobley, J. A., Dias, E. C., Andersson, M., Arteaga, C. L., Sanders, M. E., & Caprioli, R. M. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600119-mcp200 · Cited by 191
Self-citationMALDI-MS Direct Tissue Analysis of Proteins: Improving Signal Sensitivity Using Organic Treatments
Lemaire, R., Wisztorski, M., Desmons, A., Tabet, J. C., Day, R., Salzet, M., & Fournier, I. (2006) · Analytical Chemistry · doi:10.1021/ac060565z · Cited by 189
Transforming Clinical Research: The Power of High-Throughput Omics Integration
Vitorino, R. (2024) · Proteomes · doi:10.3390/proteomes12030025 · Cited by 183
“…disorders and identifying metabolic pathways that are altered in disease, enabling the profiling and imaging of tissue samples and providing information on the spatial distribution of biomolecules directly from tissue sections, which is invaluable for disease diagnosis and biomarker discovery [92].”
BackgroundMALDI Imaging Mass Spectrometry
Franck, J., Arafah, K., Elayed, M., Bonnel, D., Vergara, D., Jacquet, A., Vinatier, D., Wisztorski, M., Day, R., Fournier, I., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r800016-mcp200 · Cited by 180
Atmospheric Pressure Infrared MALDI Imaging Mass Spectrometry for Plant Metabolomics
Li, Y., Shrestha, B., & Vertes, A. (2008) · Analytical Chemistry · doi:10.1021/ac701703f · Cited by 174
Eikel, D., Vavrek, M., Smith, S., Bason, C., Yeh, S., Korfmacher, W. A., & Henion, J. D. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5274 · Cited by 170
Identifying prostate carcinoma by MALDI-Imaging
Schwamborn, K., Krieg, R., Reska, M., Jakse, G., Knuechel, R., & Wellmann, A. (2007) · International Journal of Molecular Medicine · doi:10.3892/ijmm.20.2.155 · Cited by 168
Protein and peptides in pictures: Imaging with MALDI mass spectrometry
Goodwin, R. J. A., Pennington, S. R., & Pitt, A. R. (2008) · PROTEOMICS · doi:10.1002/pmic.200800320 · Cited by 164
Wakeman, C. A., Moore, J. L., Noto, M. J., Zhang, Y., Singleton, M. D., Prentice, B. M., Gilston, B. A., Doster, R. S., Gaddy, J. A., Chazin, W. J., et al. (2016) · Nature Communications · doi:10.1038/ncomms11951 · Cited by 137
Self-citation
Metadata
- Authors
- Caldwell, R. L., & Caprioli, R. M.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2005-04
- Volume
- 4
- Issue
- 4
- Pages
- 394-401
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2106034668
- Cited by
- 259
- References
- 16
- FWCI
- 12.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.