Microfabricated ion traps
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Ion traps offer the opportunity to study fundamental quantum systems with a high level of accuracy highly decoupled from the environment. Individual atomic ions can be controlled and manipulated with electric fields, cooled to the ground state of motion with laser cooling and coherently manipulated using optical and microwave radiation. Microfabricated ion traps hold the advantage of allowing for smaller trap dimensions and better scalability towards large ion trap arrays also making them a vital ingredient for next generation quantum technologies. Here we provide an introduction into the principles and operation of microfabricated ion traps. We show an overview of material and electrical considerations which are vital for the design of such trap structures. We provide guidance on how to choose the appropriate fabrication design, consider different methods for the fabrication of microfabricated ion traps and discuss previously realised structures. We also discuss the phenomenon of anomalous heating of ions within ion traps, which becomes an important factor in the miniaturisation of ion traps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum Computations with Cold Trapped Ions
Cirac, J. I., & Zoller, P. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.4091 · Cited by 3,733 · cited 1×
“In general, ion traps compare well to other physical systems with good isolation from the environment and long coherence times.”
BackgroundDiVincenzo, D. P. (1995) · Science · doi:10.1126/science.270.5234.255 · Cited by 1,651
Architecture for a large-scale ion-trap quantum computer
Kielpinski, D., Monroe, C., & Wineland, D. J. (2002) · Nature · doi:10.1038/nature00784 · Cited by 1,589
Experimental issues in coherent quantum-state manipulation of trapped atomic ions
Wineland, D. J., Monroe, C., Itano, W. M., Leibfried, D., King, B. E., & Meekhof, D. M. (1998) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.103.019 · Cited by 1,497 · cited 2×
“The second term represents the cross-coupling between the noise and rf fields and can be neglected for axial motion in linear traps as the axial confinement is only produced via static fields [15,102].”
BackgroundQuantum computing with trapped ions
HAFFNER, H., ROOS, C., & BLATT, R. (2008) · Physics Reports · doi:10.1016/j.physrep.2008.09.003 · Cited by 1,154
Quantum simulation of frustrated Ising spins with trapped ions
Kim, K., Chang, M.-S., Korenblit, S., Islam, R., Edwards, E. E., Freericks, J. K., Lin, G.-D., Duan, L.-M., & Monroe, C. (2010) · Nature · doi:10.1038/nature09071 · Cited by 750 · cited 1×
“…Paul [1] and Hans Dehmelt [2] in the 1950s and 1960s and ion traps became an important tool to study important physical systems such as ion cavity QED [3,4], quantum simulators [5–9], determine frequency standards [10– 13], as well as the development towards a quantum information processor [14–16].”
BackgroundResolved-Sideband Raman Cooling of a Bound Atom to the 3D Zero-Point Energy
Monroe, C., Meekhof, D. M., King, B. E., Jefferts, S. R., Itano, W. M., Wineland, D. J., & Gould, P. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.4011 · Cited by 731
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720 · cited 2×
“41 K [43], well above the Doppler limit of a few milli-kelvin.”
BackgroundExperimental Determination of the Motional Quantum State of a Trapped Atom
Leibfried, D., Meekhof, D. M., King, B. E., Monroe, C., Itano, W. M., & Wineland, D. J. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.4281 · Cited by 688 · cited 1×
“Most of these criteria have been demonstrated with an ion trap: qubit initialisation [18,19], a set of universal quantum gates creating entanglement between ions [14,20–22], long coherence times [23], detection of states [24,25] and a scalable architecture to host a large number of qubits [26–29].”
BackgroundSimulating a quantum magnet with trapped ions
Friedenauer, A., Schmitz, H., Glueckert, J. T., Porras, D., & Schaetz, T. (2008) · Nature Physics · doi:10.1038/nphys1032 · Cited by 602 · cited 1×
“…Paul [1] and Hans Dehmelt [2] in the 1950s and 1960s and ion traps became an important tool to study important physical systems such as ion cavity QED [3,4], quantum simulators [5–9], determine frequency standards [10– 13], as well as the development towards a quantum information processor [14–16].”
Background
Cited by
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
“Following these investigations, several papers (e.g. Epstein et al., 2007; Hughes et al., 2011; Daniilidis et al., 2011) compiled the results of multiple experiments into a single plot, and indicated that the combined data lent support to d−4 scaling models of heating.”
ResultBlueprint for a microwave trapped ion quantum computer
Lekitsch, B., Weidt, S., Fowler, A. G., Mølmer, K., Devitt, S. J., Wunderlich, C., & Hensinger, W. K. (2017) · Science Advances · doi:10.1126/sciadv.1601540 · Cited by 292
Self-citationShuttling-based trapped-ion quantum information processing
Kaushal, V., Lekitsch, B., Stahl, A., Hilder, J., Pijn, D., Schmiegelow, C., Bermudez, A., Müller, M., Schmidt-Kaler, F., & Poschinger, U. (2020) · AVS Quantum Science · doi:10.1116/1.5126186 · Cited by 141
Self-citationReliable transport through a microfabricated X -junction surface-electrode ion trap
Wright, K., Amini, J. M., Faircloth, D. L., Volin, C., Charles Doret, S., Hayden, H., Pai, C.-S., Landgren, D. W., Denison, D., Killian, T., et al. (2013) · New Journal of Physics · doi:10.1088/1367-2630/15/3/033004 · Cited by 87
Assembling a ring-shaped crystal in a microfabricated surface ion trap
Tabakov, B., Benito, F., Blain, M., Clark, C. R., Clark, S., Haltli, R. A., Maunz, P., Sterk, J. D., Tigges, C., & Stick, D. (2015) · Physical Review Applied · doi:10.1103/physrevapplied.4.031001 · Cited by 34
“The primary motivation for developing segmented surface ion traps [1] is to create structures that support the implementation of quantum algorithms, such as the proposed quantum charge-coupled device (QCCD) [2].”
BackgroundMultilayer ion trap technology for scalable quantum computing and quantum simulation
Bautista-Salvador, A., Zarantonello, G., Hahn, H., Preciado-Grijalva, A., Morgner, J., Wahnschaffe, M., & Ospelkaus, C. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab0e46 · Cited by 27
Industrially microfabricated ion trap with 1 eV trap depth
Auchter, S., Axline, C., Decaroli, C., Valentini, M., Purwin, L., Oswald, R., Matt, R., Aschauer, E., Colombe, Y., Holz, P., et al. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac7072 · Cited by 23
Metadata
- Authors
- Hughes, M. D., Lekitsch, B., Broersma, J. A., & Hensinger, W. K.
- Venue
- Contemporary Physics
- Publisher
- Informa UK Limited
- Published
- 2011-11
- Volume
- 52
- Issue
- 6
- Pages
- 505-529
- ISSN
- 0010-7514 (ISSN-L)
- 1366-5812
- OpenAlex
- W2009853676
- Cited by
- 74
- References
- 18
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.