Exoskeletons for industrial application and their potential effects on physical work load
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The aim of this review was to provide an overview of assistive exoskeletons that have specifically been developed for industrial purposes and to assess the potential effect of these exoskeletons on reduction of physical loading on the body. The search resulted in 40 papers describing 26 different industrial exoskeletons, of which 19 were active (actuated) and 7 were passive (non-actuated). For 13 exoskeletons, the effect on physical loading has been evaluated, mainly in terms of muscle activity. All passive exoskeletons retrieved were aimed to support the low back. Ten-forty per cent reductions in back muscle activity during dynamic lifting and static holding have been reported. Both lower body, trunk and upper body regions could benefit from active exoskeletons. Muscle activity reductions up to 80% have been reported as an effect of active exoskeletons. Exoskeletons have the potential to considerably reduce the underlying factors associated with work-related musculoskeletal injury. Practitioner Summary: Worldwide, a significant interest in industrial exoskeletons does exist, but a lack of specific safety standards and several technical issues hinder mainstay practical use of exoskeletons in industry. Specific issues include discomfort (for passive and active exoskeletons), weight of device, alignment with human anatomy and kinematics, and detection of human intention to enable smooth movement (for active exoskeletons).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589 · cited 1×
“The McKibben artificial muscle (Chou and Hannaford 1996) was selected as the Muscle Suit actuator because of its light weight.”
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Wearable lower limb robotics: A review
Viteckova, S., Kutilek, P., & Jirina, M. (2013) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2013.03.005 · Cited by 221
Abdoli-E, M., Agnew, M. J., & Stevenson, J. M. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.12.021 · Cited by 218
The technical trend of the exoskeleton robot system for human power assistance
Lee, H., Kim, W., Han, J., & Han, C. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0197-x · Cited by 196
Mechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties
Gopura, R. A. R. C., & Kiguchi, K. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209630 · Cited by 192
A Review of exoskeleton-type systems and their key technologies
Yang, C.-J., Zhang, J.-F., Chen, Y., Dong, Y.-M., & Zhang, Y. (2008) · Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes936 · Cited by 187
Graham, R. B., Agnew, M. J., & Stevenson, J. M. (2009) · Applied Ergonomics · doi:10.1016/j.apergo.2009.01.006 · Cited by 170
Abdoli-Eramaki, M., & Stevenson, J. M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.10.012 · Cited by 149
Frost, D. M., Abdoli-Eramaki, M., & Stevenson, J. M. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.12.002 · Cited by 137
Ulrey, B. L., & Fathallah, F. A. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.08.014 · Cited by 134
Muscle Suit Development and Factory Application
Kobayashi, H., Aida, T., & Hashimoto, T. (2009) · International Journal of Automation Technology · doi:10.20965/ijat.2009.p0709 · Cited by 131
Abdoli-Eramaki, M., Stevenson, J. M., Reid, S. A., & Bryant, J. T. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.006 · Cited by 109
A novel linear PID controller for an upper limb exoskeleton
Yu, W., & Rosén, J. (2010) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2010.5716985 · Cited by 106
Effect of an on-body ergonomic aid on oxygen consumption during a repetitive lifting task
Whitfield, B. H., Costigan, P. A., Stevenson, J. M., & Smallman, C. L. W. (2013) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2013.10.002 · Cited by 87
Muramatsu, Y., Kobayashi, H., Sato, Y. S., Jiaou, H., Hashimoto, T., & Kobayashi, H. (2011) · International Journal of Automation Technology · doi:10.20965/ijat.2011.p0559 · Cited by 86
Ergonomics of exoskeletons: Objective performance metrics
Schiele, A. (2009) · World Haptics 2009 - Third Joint EuroHaptics conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/whc.2009.4810871 · Cited by 83
The personal lift-assist device and lifting technique: a principal component analysis
Sadler, E. M., Graham, R. B., & Stevenson, J. M. (2011) · Ergonomics · doi:10.1080/00140139.2011.556259 · Cited by 78
Subject-specific, whole-body models of the stooped posture with a personal weight transfer device
Ulrey, B. L., & Fathallah, F. A. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.08.016 · Cited by 69
Lee, H., Lee, B., Kim, W., Gil, M., Han, J., & Han, C.-S. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0128-x · Cited by 61
Working posture control of Robot Suit HAL for reducing structural stress
Kawabata, T., Satoh, H., & Sankai, Y. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.5420519 · Cited by 54
Wearable stooping-assist device in reducing risk of low back disorders during stooped work
Luo, Z., & Yu, Y. T. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6617923 · Cited by 53
Design and Biomechanical Analysis of Supernumerary Robotic Limbs
Davenport, C., Parietti, F., & Asada, H. H. (2012) · doi:10.1115/dscc2012-movic2012-8790 · Cited by 53
Development of muscle suit for supporting manual worker
Kobayashi, H., & Nozaki, H. (2007) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2007.4399412 · Cited by 40
"Skil Mate" wearable exoskeleton robot
Umetani, Y., Yamada, Y., Morizono, T., Yoshida, T., & Aoki, S. (2003) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.1999.812544 · Cited by 27
Development of Power-Assist Robot Arm using pneumatic rubbermuscles with a balloon sensor
KADOTA, K., Akai, M., Kawashima, K., & KAGAWA, T. (2009) · IEEE RO-MAN · doi:10.1109/roman.2009.5326335 · Cited by 27
DEVELOPMENT OF A LOWER EXTREMITY EXOSKELETON SYSTEM FOR WALKING ASSISTANCE WHILE LOAD CARRYING
Kim, W., LEE, H. D., Lim, D.-H., Han, C. S., & Han, J. (2013) · doi:10.1142/9789814525534_0008 · Cited by 19
Development of support system for forward tilting of the upper body
Kobayashi, H., & Nozaki, H. (2008) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2008.4798779 · Cited by 16
Cited by
Davila Delgado, J. M., Oyedele, L., Ajayi, A., Akanbi, L., Akinade, O., Bilal, M., & Owolabi, H. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100868 · Cited by 607
Substantial capabilities of robotics in enhancing industry 4.0 implementation
Javaid, M., Haleem, A., Singh, R. P., & Suman, R. (2021) · Cognitive Robotics · doi:10.1016/j.cogr.2021.06.001 · Cited by 563
Bosch, T., van Eck, J., Knitel, K., & de Looze, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.12.003 · Cited by 462
Self-citationHuysamen, K., de Looze, M., Bosch, T., Ortiz, J., Toxiri, S., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2017.11.004 · Cited by 313
Self-citationKermavnar, T., de Vries, A. W., de Looze, M. P., & O’Sullivan, L. W. (2021) · Ergonomics · doi:10.1080/00140139.2020.1870162 · Cited by 275
Self-citation
Metadata
- Authors
- de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 2015-10-07
- Volume
- 59
- Issue
- 5
- Pages
- 671-681
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2196056879
- Cited by
- 1,062
- References
- 29
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.