Exoskeletons for industrial application and their potential effects on physical work load
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The aim of this review was to provide an overview of assistive exoskeletons that have specifically been developed for industrial purposes and to assess the potential effect of these exoskeletons on reduction of physical loading on the body. The search resulted in 40 papers describing 26 different industrial exoskeletons, of which 19 were active (actuated) and 7 were passive (non-actuated). For 13 exoskeletons, the effect on physical loading has been evaluated, mainly in terms of muscle activity. All passive exoskeletons retrieved were aimed to support the low back. Ten-forty per cent reductions in back muscle activity during dynamic lifting and static holding have been reported. Both lower body, trunk and upper body regions could benefit from active exoskeletons. Muscle activity reductions up to 80% have been reported as an effect of active exoskeletons. Exoskeletons have the potential to considerably reduce the underlying factors associated with work-related musculoskeletal injury. Practitioner Summary: Worldwide, a significant interest in industrial exoskeletons does exist, but a lack of specific safety standards and several technical issues hinder mainstay practical use of exoskeletons in industry. Specific issues include discomfort (for passive and active exoskeletons), weight of device, alignment with human anatomy and kinematics, and detection of human intention to enable smooth movement (for active exoskeletons).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589 · cited 1×
“The McKibben artificial muscle (Chou and Hannaford 1996) was selected as the Muscle Suit actuator because of its light weight.”
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Wearable lower limb robotics: A review
Viteckova, S., Kutilek, P., & Jirina, M. (2013) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2013.03.005 · Cited by 221
Abdoli-E, M., Agnew, M. J., & Stevenson, J. M. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.12.021 · Cited by 218
The technical trend of the exoskeleton robot system for human power assistance
Lee, H., Kim, W., Han, J., & Han, C. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0197-x · Cited by 196
Mechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties
Gopura, R. A. R. C., & Kiguchi, K. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209630 · Cited by 192
A Review of exoskeleton-type systems and their key technologies
Yang, C.-J., Zhang, J.-F., Chen, Y., Dong, Y.-M., & Zhang, Y. (2008) · Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes936 · Cited by 187
Graham, R. B., Agnew, M. J., & Stevenson, J. M. (2009) · Applied Ergonomics · doi:10.1016/j.apergo.2009.01.006 · Cited by 170
Abdoli-Eramaki, M., & Stevenson, J. M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.10.012 · Cited by 149
Cited by
Davila Delgado, J. M., Oyedele, L., Ajayi, A., Akanbi, L., Akinade, O., Bilal, M., & Owolabi, H. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100868 · Cited by 607
Substantial capabilities of robotics in enhancing industry 4.0 implementation
Javaid, M., Haleem, A., Singh, R. P., & Suman, R. (2021) · Cognitive Robotics · doi:10.1016/j.cogr.2021.06.001 · Cited by 563
Bosch, T., van Eck, J., Knitel, K., & de Looze, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.12.003 · Cited by 462
Self-citationHuysamen, K., de Looze, M., Bosch, T., Ortiz, J., Toxiri, S., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2017.11.004 · Cited by 313
Self-citationKermavnar, T., de Vries, A. W., de Looze, M. P., & O’Sullivan, L. W. (2021) · Ergonomics · doi:10.1080/00140139.2020.1870162 · Cited by 275
Self-citationOpportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Evaluation of a passive exoskeleton for static upper limb activities
Huysamen, K., Bosch, T., de Looze, M., Stadler, K. S., Graf, E., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.02.009 · Cited by 253
Self-citationGovaerts, R., Tassignon, B., Ghillebert, J., Serrien, B., De Bock, S., Ampe, T., El Makrini, I., Vanderborght, B., Meeusen, R., & De Pauw, K. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04615-9 · Cited by 220
Ageing workforce management in manufacturing systems: state of the art and future research agenda
Calzavara, M., Battini, D., Bogataj, D., Sgarbossa, F., & Zennaro, I. (2020) · International Journal of Production Research · doi:10.1080/00207543.2019.1600759 · Cited by 208
“(2000) Jeong (1999) Chung and Kee (2000) Gaudart (2000) Marszałek (2000) Räsänen, Laitinen, and Rasa (2000) King (2002) Pennathur, Contreras, et al. (2003) Pennathur, Magham, et al.”
BackgroundInfluentialPassive Back Support Exoskeleton Improves Range of Motion Using Flexible Beams
Näf, M. B., Koopman, A. S., Baltrusch, S., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00072 · Cited by 207
Crea, S., Beckerle, P., De Looze, M., De Pauw, K., Grazi, L., Kermavnar, T., Masood, J., O’Sullivan, L. W., Pacifico, I., Rodriguez-Guerrero, C., et al. (2021) · Wearable Technologies · doi:10.1017/wtc.2021.11 · Cited by 206
“The bending position was typically determined by trunk flexion angle (40 – 55°; Bosch et al., 2016; Wei et al., 2020a), or hand distance from the floor (Kim et al., 2020b).”
InfluentialSelf-citationKim, S., Nussbaum, M. A., Mokhlespour Esfahani, M. I., Alemi, M. M., Jia, B., & Rashedi, E. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.02.024 · Cited by 205
Theurel, J., & Desbrosses, K. (2019) · IISE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/24725838.2019.1638331 · Cited by 203
“(2016) observed a significant hyper-extension of the knees among operators wearing a passive EXOBK (Laevo V1) when they bent forward. Abdoli et al. (2006) found a significant increase in plantar flexion (þ5.5%) when using a passive EXOBK (PLAD) during a static task (i.e., 30 trunk flexion in the sagittal plane). In th…”
BackgroundMethodEffects of a passive exoskeleton on the mechanical loading of the low back in static holding tasks
Koopman, A. S., Kingma, I., Faber, G. S., de Looze, M. P., & van Dieën, J. H. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.033 · Cited by 192
“Still, many workers are exposed to tiring and painful positions and are required to lift heavy loads at least a quarter of the work time (Eurofound, 2012).”
BackgroundSelf-citationKim, S., Moore, A., Srinivasan, D., Akanmu, A., Barr, A., Harris-Adamson, C., Rempel, D. M., & Nussbaum, M. A. (2019) · IISE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/24725838.2018.1561557 · Cited by 189
A passive exoskeleton reduces peak and mean EMG during symmetric and asymmetric lifting
Alemi, M. M., Geissinger, J., Simon, A. A., Chang, S. E., & Asbeck, A. T. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.05.003 · Cited by 189
Toxiri, S., Koopman, A. S., Lazzaroni, M., Ortiz, J., Power, V., de Looze, M. P., O'Sullivan, L., & Caldwell, D. G. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00053 · Cited by 171
Self-citationAlemi, M. M., Madinei, S., Kim, S., Srinivasan, D., & Nussbaum, M. A. (2020) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819897669 · Cited by 170
“Generally, occupational exoskeletons are classified as either “active” or “passive” (de Looze et al., 2016; Lee et al., 2012).”
BackgroundTapping into the wearable device revolution in the work environment: a systematic review
Khakurel, J., Melkas, H., & Porras, J. (2018) · Information Technology & People · doi:10.1108/itp-03-2017-0076 · Cited by 163
“…muscular diseases by lowering physical strain on the body and improving work efficiency (Chu et al., 2014; Luo and Yu, 2013), one potential problem with wearable exoskeletons is that safety standards for their usage in work environments have not yet been formalised (de Looze et al., 2015).”
BackgroundBär, M., Steinhilber, B., Rieger, M. A., & Luger, T. (2021) · Applied Ergonomics · doi:10.1016/j.apergo.2021.103385 · Cited by 161
Mauck, M. C., Aylward, A. F., Barton, C. E., Birckhead, B., Carey, T., Dalton, D. M., Fields, A. J., Fritz, J., Hassett, A. L., Hoffmeyer, A., et al. (2022) · PAIN Reports · doi:10.1097/pr9.0000000000001019 · Cited by 49
Ojha, A., Gautam, Y., Jebelli, H., & Akanmu, A. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105742 · Cited by 39
Telling autonomous systems what to do
Werkhoven, P., Kester, L., & Neerincx, M. (2018) · Proceedings of the 36th European Conference on Cognitive Ergonomics · doi:10.1145/3232078.3232238 · Cited by 19
Metadata
- Authors
- de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 2015-10-07
- Volume
- 59
- Issue
- 5
- Pages
- 671-681
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2196056879
- Cited by
- 1,062
- References
- 29
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.