Evaluation of commercial, wireless dermal thermometers for surrogate measurements of core temperature
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Extensive research has been devoted to developing methods for assessing core body temperature, and to determine which method is most accurate. A number of wireless dermal thermometers for home use are presently available, but their relation to core body temperature and suitability for use in clinical research has hitherto not been assessed. The current study aimed to evaluate such thermometers by comparing them to the results of a rectal thermometer. Four wireless dermal thermometers for home use (FeverSmart, iThermonitor, Quest Temp Sitter, and Thermochron iButton) were applied to 15 patients during 24 h, and rectal temperature was measured at four occasions. Pearson correlation revealed moderate correlation for the Feversmart (r = 0.75), iThermonitor (r = 0.79), and Thermochron iButton (r = 0.71) systems. The Quest Temp Sitter system malfunctioned repeatedly, and the correlation (r = 0.29) for this method should therefore be assessed with caution. All dermal thermometers rendered lower average temperatures than Terumo c405 (Feversmart -0.70 ± 0.65 °C; iThermonitor -0.77 ± 0.53 °C, Quest Temp Sitter -1.18 ± 0.66 °C, and Thermochron iButton -0.87 ± 0.65 °C). Sensitivity of the dermal thermometers for detecting core temperatures ≥38.0 °C was low, ranging from 0.33 to 0.6, but improved to 0.60 to 0.80 after adjusting temperatures by the methods' average deviation from rectal temperature. The results from the dermal thermometers tested here showed an insufficient correlation to core temperature to be used for core temperature monitoring in clinical research and practice. Unfortunately, other options for non-invasive temperature measurements are few. The two thermometers with the least unsatisfactory performance profile in our evaluations were the Feversmart and iThermonitor systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420 · cited 1×
“These inconsistencies in the average difference and the difficulty to adjust axillary temperature to rectal temperature has led to the conclusion that axillary methods are not an acceptable substitution for the rectal method, which is supported by the current results [13].”
ResultEvaluation of wireless determination of skin temperature using iButtons
VANMARKENLICHTENBELT, W., DAANEN, H., WOUTERS, L., FRONCZEK, R., RAYMANN, R., SEVERENS, N., & VANSOMEREN, E. (2006) · Physiology & Behavior · doi:10.1016/j.physbeh.2006.04.026 · Cited by 392
Research works printed but not linked: 11
- 10.1016/j.ijnurstu.2009.05.002 · DOI
- 10.1186/s13049-015-0178-z · DOI
- 10.1016/j.ijnurstu.2008.11.006 · DOI
- 10.1007/s00134-002-1619-5 · DOI · Paper page
- 10.1016/S0736-4679(01)00457-7 · DOI
- 10.4085/1062-6050-47.3.09 · DOI · Paper page
- 10.1016/j.jtherbio.2014.08.010 · DOI
- 10.1016/j.sleep.2010.12.011 · DOI
- 10.1016/j.pedn.2011.04.004 · DOI
- 10.1016/j.ejon.2009.03.006 · DOI
- 10.1016/j.ijnurstu.2010.11.003 · DOI
Cited by
Khaksari, K., Nguyen, T., Hill, B. Y., Perrault, J., Gorti, V., Blick, E., Gonzalez Cano, T., Shadgan, B., Quang, T., Malpani, R., et al. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.s1.010901 · Cited by 55
Pecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“Balla 2019 [25] Cross-sectional Neurological and infection wards Adult 15 Rectal, digital Axillary, thermistor”
Liu, Y., Liu, C., Gao, M., Wang, Y., Bai, Y., Xu, R., & Gong, R. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-039474 · Cited by 35
Oltra, M., Vidal-Gil, L., Maisto, R., Oltra, S. S., Romero, F. J., Sancho-Pelluz, J., & Barcia, J. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-54373-x · Cited by 24
Berge, S. T., Safi, N., Medhus, A. W., Sundhagen, J. O., Hisdal, J., & Kazmi, S. S. (2020) · Vascular Health and Risk Management · doi:10.2147/vhrm.s252192 · Cited by 13
Metadata
- Authors
- Zsuzsanna Balla, H., Theodorsson, E., & Ström, J. O.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 2019-02-17
- Volume
- 79
- Issue
- 1-2
- Pages
- 1-6
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2921705185
- Cited by
- 14
- References
- 2
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of commercial, wireless dermal thermometers for surrogate measurements of core temperature. https://app.cochat.ai/papers/10.1080/00365513.2018.1519722
- The paper
- Zsuzsanna Balla, H., Theodorsson, E., & Ström, J. O. (2019). Evaluation of commercial, wireless dermal thermometers for surrogate measurements of core temperature. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365513.2018.1519722
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.