Decision boundaries and receiver operating characteristic curves: New methods for determining accelerometer cutpoints
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We propose and evaluate the utility of an alternative method (decision boundaries) for establishing physical activity intensity-related accelerometer cutpoints. Accelerometer data collected from seventy-six 11- to 14-year-old boys during controlled bouts of moderate- and vigorous-intensity field physical activities were assessed. Mean values and standard deviations for moderate- and vigorous-intensity activities were obtained and normal equivalents generated. The decision boundary (the point of intersection of overlapping distributions) was used to create a lower-bound vigorous-intensity cutpoint. Receiver operating characteristic (ROC) curves compared the sensitivity and specificity of the new cutpoint and mean values with the actual activity. There was a 96.5% probability that participants performing vigorous-intensity physical activity were accurately classified when using the decision boundary of 6700 counts per minute, in contrast to the 50% accurately classified when the mean value was used. Inspection of the empirical ROC curve indicated that the decision boundary provided the optimal threshold to distinguish between moderate and vigorous physical activity for this dataset. In conclusion, decision boundaries reduced the error associated with determining accelerometer threshold values. Applying these methods to accelerometer data collected in specific populations will improve the precision with which accelerometer thresholds can be identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 2×
“…0264-0414 print/ISSN 1466-447X online 2007 Taylor & Francis DOI: 10.1080/02640410600908027 between energy expenditure and accelerometer counts (Freedson et al., 1998; Hendelman et al., 2000; Nichols et al., 2000; Puyau et al., 2002; Swartz et al., 2000; Treuth et al., 2003b).”
BackgroundMethodInfluentialValidity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769 · cited 2×
“One approach to setting thresholds for different intensities uses regression formulae to convert the accelerometer counts recorded during laboratory treadmill activity to directly monitored energy expenditures (Melanson & Freedson, 1995; Swartz et al., 2000; Trost et al., 1998).”
MethodCompliance with physical activity guidelines: prevalence in a population of children and youth
Pate, R. (2002) · Annals of Epidemiology · doi:10.1016/s1047-2797(01)00263-0 · Cited by 472 · cited 2×
“…Biotrainer have been used extensively to assess both the physical activity patterns and intensities of children, adolescents, and adults (Baranowski et al., 2003; Chen et al., 2003; Ekelund et al., 2001; Pate et al., 2002; Robinson et al., 2003; Sarna & Conde, 2001; Welk, Almeida, & Morss, 2003).”
MethodMacIntyre, P., Fisher, M., Kirk, A., & Mutrie, N. (2004) · Diabetologia · doi:10.1007/s00125-004-1396-5 · Cited by 139 · cited 1×
“As several interventions have attempted to increase the physical activity of children and adults (Baranowski et al , 2003 ; Kirk, Mutrie, MacIntyre, & Fisher, 2004 ), using an accurate cutpoint to determine whether the intervention was successful is extremely important.”
BackgroundThe role of physical activity in prevention and treatment of body weight gain in adults
Jakicic, J. M. (2002) · The Journal of Nutrition · doi:10.1093/jn/132.12.3826s · Cited by 118
Cited by
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Comparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Warren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587
Evaluation of raw acceleration sedentary thresholds in children and adults
Hildebrand, M., Hansen, B. H., van Hees, V. T., & Ekelund, U. (2017) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12795 · Cited by 425
Calibration and Validation of Wearable Monitors
BASSETT, D. R., ROWLANDS, A., & TROST, S. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399cf7 · Cited by 292
Moderate and vigorous physical activity intensity cut-points for the Actical accelerometer
Colley, R. C., & Tremblay, M. S. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2011.557744 · Cited by 200
“The mean values for each intensity were then used as theoretical cut-points to classify light, moderate, and vigorous intensity physical activity on the test data set (Jago et al., 2007).”
InfluentialValidation of the GT3X ActiGraph in children and comparison with the GT1M ActiGraph
Hänggi, J. M., Phillips, L. R. S., & Rowlands, A. V. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.05.012 · Cited by 196
Field evaluation of a random forest activity classifier for wrist-worn accelerometer data
Pavey, T. G., Gilson, N. D., Gomersall, S. R., Clark, B., & Trost, S. G. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2016.06.003 · Cited by 174
Use of a Two-Regression Model for Estimating Energy Expenditure in Children
CROUTER, S. E., HORTON, M., & BASSETT, D. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182447825 · Cited by 75
“Alternatively, researehers have examined other approaches for analyzing aecelerometer data, including receiver operating characteristies, for use in children, (11,13,28), whereas in adults, approaches sueh as a two-regression model (2RM) (5,6,8) and pattern recognition (e.”
Metadata
- Authors
- Jago, R., Zakeri, I., Baranowski, T., & Watson, K.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2007-06
- Volume
- 25
- Issue
- 8
- Pages
- 937-944
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2089506576
- Cited by
- 71
- References
- 6
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.