The accuracy and precision of DXA for assessing body composition in team sport athletes
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
This study determined the precision of pencil and fan beam dual-energy X-ray absorptiometry (DXA) devices for assessing body composition in professional Australian Football players. Thirty-six professional Australian Football players, in two groups (fan DXA, N = 22; pencil DXA, N = 25), underwent two consecutive DXA scans. A whole body phantom with known values for fat mass, bone mineral content and fat-free soft tissue mass was also used to validate each DXA device. Additionally, the criterion phantom was scanned 20 times by each DXA to assess reliability. Test-retest reliability of DXA anthropometric measures were derived from repeated fan and pencil DXA scans. Fat-free soft tissue mass and bone mineral content from both DXA units showed strong correlations with, and trivial differences to, the criterion phantom values. Fat mass from both DXA showed moderate correlations with criterion measures (pencil: r = 0.64; fan: r = 0.67) and moderate differences with the criterion value. The limits of agreement were similar for both fan beam DXA and pencil beam DXA (fan: fat-free soft tissue mass = -1650 ± 179 g, fat mass = -357 ± 316 g, bone mineral content = 289 ± 122 g; pencil: fat-free soft tissue mass = -1701 ± 257 g, fat mass = -359 ± 326 g, bone mineral content = 177 ± 117 g). DXA also showed excellent precision for bone mineral content (coefficient of variation (%CV) fan = 0.6%; pencil = 1.5%) and fat-free soft tissue mass (%CV fan = 0.3%; pencil = 0.5%) and acceptable reliability for fat measures (%CV fan: fat mass = 2.5%, percent body fat = 2.5%; pencil: fat mass = 5.9%, percent body fat = 5.7%). Both DXA provide precise measures of fat-free soft tissue mass and bone mineral content in lean Australian Football players. DXA-derived fat-free soft tissue mass and bone mineral content are suitable for assessing body composition in lean team sport athletes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progressive Statistics for Studies in Sports Medicine and Exercise Science
HOPKINS, W. G., MARSHALL, S. W., BATTERHAM, A. M., & HANIN, J. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31818cb278 · Cited by 9,128
International Standards for Anthropometric Assessment (2006)
Marfell-Jones, M., Olds, T., Stewart, A. D., & Carter, L. (2006) · VUBIR (Vrije Universiteit Brussel) · Cited by 2,851
Ackland, T. R., Lohman, T. G., Sundgot-Borgen, J., Maughan, R. J., Meyer, N. L., Stewart, A. D., & Müller, W. (2012) · Sports Medicine · doi:10.2165/11597140-000000000-00000 · Cited by 599 · cited 1×
“In contrast, fan beam technology uses wider X-ray beams, allowing faster scanning and better image resolution but at the cost of higher radiation dosage and magnification errors (Ackland et al., 2012; Soriano et al., 2004).”
BackgroundToombs, R. J., Ducher, G., Shepherd, J. A., & De Souza, M. J. (2012) · Obesity · doi:10.1038/oby.2011.211 · Cited by 337 · cited 7×
“9%, with the majority showing an underestimation of fat with leaner populations (Prior et al., 2001; Toombs et al., 2012; Van Der Ploeg et al., 2003; Williams et al., 2006).”
BackgroundInfluentialLukaski, H. C. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.149 · Cited by 303 · cited 2×
“…study are the nature of the homogenous group investigated, lack of standardisation in hydration and rest status, the measurement noise from the BIA methods (Lukaski, 2013) and non-linear relationship between subcutaneous fat and fat mass – especially in very lean or obese individuals (Roche, 1987).”
Schoeller, D. A., Tylavsky, F. A., Baer, D. J., Chumlea, W. C., Earthman, C. P., Fuerst, T., Harris, T. B., Heymsfield, S. B., Horlick, M., Lohman, T. G., et al. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.5.1018 · Cited by 253 · cited 1×
“However, it has previously been shown that DXA estimation for fatfree soft tissue mass and fat mass can vary significantly among differing models (hardware and software) under different laboratory conditions (Nana, Slater, Hopkins, & Burke, 2012; Schoeller et al., 2005).”
BackgroundWilliams, J. E., Wells, J. C., Wilson, C. M., Haroun, D., Lucas, A., & Fewtrell, M. S. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/83.5.1047 · Cited by 199 · cited 1×
“These studies have shown differences between DXA and criterion measures in percent body fat ranging from −5.3% to 2.9%, with the majority showing an underestimation of fat with leaner populations (Prior et al., 2001; Toombs et al., 2012; Van Der Ploeg et al., 2003; Williams et al., 2006).”
BackgroundInfluentialNANA, A., SLATER, G. J., HOPKINS, W. G., & BURKE, L. M. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318228b60e · Cited by 197 · cited 6×
“Therefore, while acknowledging that the present approach may increase measurement error, we suggest that our approach may also explain why the reliability measures in some variables in the current study are slightly higher than recent similar reports in strength athletes and trained cyclists (Nana et al., 2012).”
BackgroundResultInfluentialA Framework for the Physical Development of Elite Rugby Union Players
Duthie, G. M. (2006) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.1.1.2 · Cited by 170 · cited 2×
“In high-performance athletes, both fat-free soft tissue mass and fat mass are of particular interest as they impact physical performance (Behnke & Royce, 1966; Stewart, 2001) and risk of injury and illness (Duthie, 2006; Hagmar, Berglund, Brismar, & Hirschberg, 2013).”
BackgroundPercent body fat via DEXA: comparison with a four-compartment model
van der Ploeg, G. E., Withers, R. T., & Laforgia, J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00436.2002 · Cited by 163 · cited 3×
“It has been suggested that DXA measurement accuracy for fat mass is poorer in leaner individuals (Toombs et al., 2012; Van Der Ploeg et al., 2003), but the precision is comparable to non-exercising populations (Toombs et al., 2012).”
BackgroundInfluentialLOHMAN, T. G., HARRIS, M., TEIXEIRA, P. J., & WEISS, L. (2000) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2000.tb06420.x · Cited by 153
Rothney, M. P., Martin, F., Xia, Y., Beaumont, M., Davis, C., Ergun, D. L., Fay, L. B., Ginty, F., Kochhar, S., Wacker, W. K., et al. (2012) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2012.02.009 · Cited by 141 · cited 2×
“While many studies have assessed the measurement precision of DXA in healthy population (Rothney et al., 2012), relatively few studies (Pineau, Filliard, & Bocquet, 2009; Santos et al.”
BackgroundD. Stewart, A., & Hannan, W. J. (2000) · Journal of Sports Sciences · doi:10.1080/026404100365009 · Cited by 137 · cited 3×
“E-mail: bcb1@iprimus.com.au © 2014 Taylor & Francis method for assessing fat mass and fat-free soft tissue mass in athletes (Stewart & Hannan, 2000; Stewart & Sutton, 2012).”
MethodResultHow big does my sample need to be? A primer on the murky world of sample size estimation
Batterham, A. M., & Atkinson, G. (2005) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2005.05.004 · Cited by 136 · cited 1×
“The present reliability data also allow us to use the approach of Batterham and Atkinson (2005) who use a nomogram and the test %CV to determine appropriate sample sizes for single group design studies with a statistical power of 90%.”
MethodWong, W. W., Hergenroeder, A. C., Stuff, J. E., Butte, N. F., Smith, E. O., & Ellis, K. J. (2002) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.2.384 · Cited by 124 · cited 1×
“Despite this, several studies that compared DXA to a four-compartment model showed a mean underestimation of percent body fat (Toombs, Ducher, Shepherd, & De Souza, 2012; Wong et al., 2002), with underestimation greater in leaner individuals (Van Der Ploeg, Withers, & Laforgia, 2003).”
ResultReliability and validity of body composition measures in female athletes
Fornetti, W. C., Pivarnik, J. M., Foley, J. M., & Fiechtner, J. J. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.3.1114 · Cited by 120 · cited 3×
“These observations agree with many previous studies that have also shown poor measurement reliability of various BIA methods for estimating fat mass in lean athletes (De Lorenzo et al., 2000; Fornetti et al., 1999).”
ResultMuscularity and the density of the fat-free mass in athletes
Prior, B. M., Modlesky, C. M., Evans, E. M., Sloniger, M. A., Saunders, M. J., Lewis, R. D., & Cureton, K. J. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.4.1523 · Cited by 93 · cited 2×
“Specifically, high levels of musculoskeletal development and elevated bone mineral density in this trained population may result in differing proportions of water, mineral and protein to the normal population (Prior et al., 2001).”
BackgroundInfluentialSantos, D. A., Silva, A. M., Matias, C. N., Fields, D. A., Heymsfield, S. B., & Sardinha, L. B. (2010) · Nutrition & Metabolism · doi:10.1186/1743-7075-7-22 · Cited by 91 · cited 6×
“, 2012), relatively few studies (Pineau, Filliard, & Bocquet, 2009; Santos et al., 2010) have compared the measurement precision of DXA in trained athletes.”
BackgroundResultInfluentialBody Composition in Sport, Exercise and Health
(2012) · Routledge eBooks · doi:10.4324/9780203133040 · Cited by 86 · cited 1×
“E-mail: bcb1@iprimus.com.au © 2014 Taylor & Francis method for assessing fat mass and fat-free soft tissue mass in athletes (Stewart & Hannan, 2000; Stewart & Sutton, 2012).”
MethodPencil-Beam vs Fan-Beam Dual-Energy X-Ray Absorptiometry Comparisons Across Four Systems
Soriano, J.-M. P., Ioannidou, E., Wang, J., Thornton, J. C., Horlick, M. N. B., Gallagher, D., Heymsfield, S. B., & Pierson, R. N. (2004) · Journal of Clinical Densitometry · doi:10.1385/jcd:7:3:281 · Cited by 79 · cited 2×
“Notably, while the coefficients of variation for fat mass were similar between DXA units, the moderate differences in fat mass may be attributed to the different analysis software and algorithms used to determine the compartmental masses (Malouf et al., 2013; Soriano et al., 2004).”
BackgroundUltrasound Techniques Applied to Body Fat Measurement in Male and Female Athletes
Pineau, J., Filliard, J. R., & Bocquet, M. (2009) · Yearbook of Sports Medicine · doi:10.1016/s0162-0908(09)79582-0 · Cited by 69
Buehring, B., Krueger, D. C., Libber, J., Heiderscheit, B. C., Sanfilippo, J. L., Johnson, B., Haller, I. V., & Binkley, N. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.02.012 · Cited by 62 · cited 1×
“Due to its speed of measure compared to four-compartment models and good level of accuracy, DXA is widely used to evaluate body composition in athletes (Buehring et al., 2014).”
BackgroundBody composition measurement in highly trained male athletes. A comparison of three methods.
LORENZO, A. D., Bertini, I., Iacopino, L., Pagliato, E., Testolin, C., & Testolin, G. (2000) · PubMed · Cited by 54
Estimation of Body Composition in Competitive Swimmers by Means of Three Different Techniques
Avlonitou, E., Georgiou, E., Douskas, G., & Louizi, A. (1997) · International Journal of Sports Medicine · doi:10.1055/s-2007-972647 · Cited by 51
Clarys, J. P., Scafoglieri, A., Provyn, S., Louis, O., Wallace, J. A., & Mey, J. D. (2009) · Obesity · doi:10.1038/oby.2009.447 · Cited by 51 · cited 2×
“, 2010; Stewart & Hannan, 2000) and non-athletic populations as well as dissection and ashingmethods in animals (Clarys et al., 2010; Hunter et al., 2011).”
BackgroundSilva, A. M., Fields, D. A., Quitério, A., & Sardinha, L. B. (2009) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181b3f0e4 · Cited by 51
Body Composition and Endocrine Profile of Male Olympic Athletes Striving for Leanness
Hagmar, M., Berglund, B., Brismar, K., & Hirschberg, A. L. (2013) · Clinical Journal of Sport Medicine · doi:10.1097/jsm.0b013e31827a8809 · Cited by 50
Clinical Observations in Total Body DXA: Technical Aspects of Positioning and Analysis
Libber, J., Binkley, N., & Krueger, D. C. (2012) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2011.12.003 · Cited by 42
Malouf, J., Di, G. S., del Río, L., Torres, F., Marin, A. M., Farrerons, J., Herrera, S., & Domingo, P. (2012) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2012.04.003 · Cited by 30 · cited 1×
“Notably, while the coefficients of variation for fat mass were similar between DXA units, the moderate differences in fat mass may be attributed to the different analysis software and algorithms used to determine the compartmental masses (Malouf et al., 2013; Soriano et al., 2004).”
BackgroundDXA Provides a Valid Minimum Weight in Wrestlers
CLARK, R. R., SULLIVAN, J. C., Bartok, C., & Carrel, A. L. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31814fb423 · Cited by 24
Body size, shape, and composition of several types of athletes.
Behnke, A. R., & Royce, J. (1966) · PubMed · Cited by 22
Ellis, K. J. (2004) · KARGER eBooks · doi:10.1159/000078279 · Cited by 17
Assessing body composition in athletes
Stewart, A. D. (2001) · Nutrition · doi:10.1016/s0899-9007(01)00545-7 · Cited by 16 · cited 1×
“In high-performance athletes, both fat-free soft tissue mass and fat mass are of particular interest as they impact physical performance (Behnke & Royce, 1966; Stewart, 2001) and risk of injury and illness (Duthie, 2006; Hagmar, Berglund, Brismar, & Hirschberg, 2013).”
BackgroundPłudowski, P., Jaworski, M., Matusik, H., Kóbylińska, M., Klimek, P., & Lorenc, R. S. (2010) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2009.11.001 · Cited by 13 · cited 1×
“With pencil DXA technology, X-ray beams pass through a narrow collimator and data are acquired via a rectilinear pattern separated by a few millimetres over the longitudinal axis of the patient (Pludowski et al., 2010).”
Method
Cited by
Pitfalls in the measurement of muscle mass: A need for a reference standard
Buckinx, F., Landi, F., Cesari, M., Fielding, R. A., Visser, M., Engelke, K., Maggi, S., Dennison, E., Al‐Daghri, N. M., Allepaerts, S., et al. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12268 · Cited by 765
Collins, J., Maughan, R. J., Gleeson, M., Bilsborough, J., Jeukendrup, A., Morton, J. P., Phillips, S. M., Armstrong, L., Burke, L. M., Close, G. L., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2019-101961 · Cited by 303
Self-citationTavella, T., Rampelli, S., Guidarelli, G., Bazzocchi, A., Gasperini, C., Pujos-Guillot, E., Comte, B., Barone, M., Biagi, E., Candela, M., et al. (2021) · Gut Microbes · doi:10.1080/19490976.2021.1880221 · Cited by 298
Reference Values for Skeletal Muscle Mass – Current Concepts and Methodological Considerations
Walowski, C. O., Braun, W., Maisch, M. J., Jensen, B., Peine, S., Norman, K., Müller, M. J., & Bosy-Westphal, A. (2020) · Nutrients · doi:10.3390/nu12030755 · Cited by 200
Body Fat Assessment in Elite Soccer Players: Cross-Validation of Different Field Methods
Suarez-Arrones, L., Petri, C., Maldonado, R. A., Torreno, N., Munguía-Izquierdo, D., Di Salvo, V., & Méndez-Villanueva, A. (2018) · Science and Medicine in Football · doi:10.1080/24733938.2018.1445871 · Cited by 40
“The use of DXA as reference method is a limitation because despite of DXA is widely used and accepted as a practical criterion, it have shown moderate precision and accuracy of %FM assessments in highly-trained team sport players (Bilsborough et al. 2014).”
MethodInfluential
Metadata
- Authors
- Bilsborough, J. C., Greenway, K., Opar, D., Livingstone, S., Cordy, J., & Coutts, A. J.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2014-06-10
- Volume
- 32
- Issue
- 19
- Pages
- 1821-1828
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2118145562
- Cited by
- 171
- References
- 34
- FWCI
- 8.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.